• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Megger® Hand-Held TDR / Cable Length Meter Megger® Hand
Megger® Hand-Held TDR / Cable Length Meter Megger® Hand

... Handheld TTR with 6ft (1.8m) test leads Test leads, X/H winding, 12ft (3.6m) Test leads, X/H winding, 20ft (6m) Battery/line power thermal printer with paper, battery pack, charger, interface cable ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

section 220519 - meters and gauges for plumbing
section 220519 - meters and gauges for plumbing

... Install all devices as required by code and the Authority Having Jurisdiction, and as recommended by the equipment manufacturer. ...
PDF
PDF

... topologies, respectively. The two-level circuit gives an output voltage with a stepwise change equal to the direct current voltage of E, whereas the three-level topologies give a stepwise change of E/2, which provides an output voltage closer to a sine wave, and thus the size of filter circuit can b ...
MAX9647/MAX9648 General-Purpose, Low-Voltage, Tiny Pack Comparators EVALUATION KIT AVAILABLE
MAX9647/MAX9648 General-Purpose, Low-Voltage, Tiny Pack Comparators EVALUATION KIT AVAILABLE

... Comparator Output (Open Drain) ...
bus ele pp 10521 mv fuses quikship
bus ele pp 10521 mv fuses quikship

... solution for virtually every medium voltage application. From our standard CLE ferrule fuses to our HCL clip-lock mounted fuses, we have solutions for your needs. We offer a wide range of voltages and ampacitites that span 2.4kV to 38kV and 1 to 1350 amps. Additionaly, options and accessories such a ...
Choosing the MAX1932 External Inductor, Diode
Choosing the MAX1932 External Inductor, Diode

HALF WAVE AND FULL WAVE RECTIFIER CIRCUITS
HALF WAVE AND FULL WAVE RECTIFIER CIRCUITS

3M™ Overhead Projectors
3M™ Overhead Projectors

... you should set the lamp switch on “low” for normal illumination. Operating the projector on the low setting will extend lamp life. High settings can be used when extra brightness is needed or images are too dim. Q. What is a metal halide lamp? A. Metal halide lamps in projectors, such as the Model ...
DTC C0235-C0237 or P0609 Circuit Description The powertrain
DTC C0235-C0237 or P0609 Circuit Description The powertrain

... Does the voltage measure within the specified range the entire time the driveshaft is rotating? ...
AM-540 AM-550 AM-540-EUR AM-550-EUR
AM-540 AM-550 AM-540-EUR AM-550-EUR

... The multimeter designed for professional HVAC technicians. The AM-540 / AM-540-EURmeasures a complete range of electrical parameters and features key functions such as temperature, capacitance to check the motor startup capacitors, micro amps for flame sensor troubleshooting, and a low pass filter t ...
FDS6676AS 30V N SyncFET
FDS6676AS 30V N SyncFET

... Thermal characterization performed using the conditions described in Note 1c. Transient thermal response will change depending on the circuit board design. ...
Detailed Design Review Presentation
Detailed Design Review Presentation

... The maximum junction temperature calculated is well below the maximum junction temperature listed in the datasheet of 125°C and therefore, pending temperature testing, no additional heat dissipation will be needed for this component. For motor and servo power the voltage needs to be regulated from 7 ...
AP7115
AP7115

... The AP7115 is a 150mA, fixed output voltage, low dropout linear regulator. The device includes pass element, error amplifier, band gap reference, current-limit and thermal shutdown circuit. The characteristics of low dropout voltage and low quiescent current make it suitable for use in battery power ...
Using a Shunt Resistor to Dissipate Energy
Using a Shunt Resistor to Dissipate Energy

... Otherwise, the bus voltage Vbus will rise and may cause damage to the bus components that cannot withstand the high voltage level. Normally, we allow a voltage rise up to 90% of the drive's maximum voltage rating before engaging the shunt resistor (unless there are other voltage-sensitive components ...
BDTIC  www.BDTIC.com/infineon TLE4946-1L
BDTIC www.BDTIC.com/infineon TLE4946-1L

... Output fall time ...
Today`s Slides
Today`s Slides

Introduction to Multisim – Part 1 Prepared by: Mohamad Eid
Introduction to Multisim – Part 1 Prepared by: Mohamad Eid

Current Sharing with Power Supplies | CUI Inc
Current Sharing with Power Supplies | CUI Inc

Fault Diagnosis on Medium Voltage (MV) Electric Power Distribution
Fault Diagnosis on Medium Voltage (MV) Electric Power Distribution

... types of faults: short-circuits, over voltages, overloads and line ruptures (loss of phase). A Short-circuit is the contact between two live conductors or between a live conductor and the earth conductor. It results in a rapid flow of current between the source and the fault. This current is limited ...
exam1_solutions
exam1_solutions

OWNER`S MANUAL - Incriminator Audio
OWNER`S MANUAL - Incriminator Audio

... amplifier for your new automotive sound system. Like all of Incriminator Audio products, the IA Series amplifiers are designed with only one thing in mind.....Performance! The new 2013 models have been completely redesigned, and come with many performance upgrades from the previous models, such as r ...
DANGER
DANGER

Shedding Light on HID Ballast Control
Shedding Light on HID Ballast Control

... further insight to the nature of HID lamps and the circuits that control them. ...
AD823 Dual 16 MHz, Rail-to-Rail FET Input Amplifier Data Sheet
AD823 Dual 16 MHz, Rail-to-Rail FET Input Amplifier Data Sheet

< 1 ... 1121 1122 1123 1124 1125 1126 1127 1128 1129 ... 2207 >

Resistive opto-isolator



Resistive opto-isolator (RO), also called photoresistive opto-isolator, vactrol (after a genericized trademark introduced by Vactec, Inc. in the 1960s), analog opto-isolator or lamp-coupled photocell, is an optoelectronic device consisting of a source and detector of light, which are optically coupled and electrically isolated from each other. The light source is usually a light-emitting diode (LED), a miniature incandescent lamp, or sometimes a neon lamp, whereas the detector is a semiconductor-based photoresistor made of cadmium selenide (CdSe) or cadmium sulfide (CdS). The source and detector are coupled through a transparent glue or through the air.Electrically, RO is a resistance controlled by the current flowing through the light source. In the dark state, the resistance typically exceeds a few MOhm; when illuminated, it decreases as the inverse of the light intensity. In contrast to the photodiode and phototransistor, the photoresistor can operate in both the AC and DC circuits and have a voltage of several hundred volts across it. The harmonic distortions of the output current by the RO are typically within 0.1% at voltages below 0.5 V.RO is the first and the slowest opto-isolator: its switching time exceeds 1 ms, and for the lamp-based models can reach hundreds of milliseconds. Parasitic capacitance limits the frequency range of the photoresistor by ultrasonic frequencies. Cadmium-based photoresistors exhibit a ""memory effect"": their resistance depends on the illumination history; it also drifts during the illumination and stabilizes within hours, or even weeks for high-sensitivity models. Heating induces irreversible degradation of ROs, whereas cooling to below −25 °C dramatically increases the response time. Therefore, ROs were mostly replaced in the 1970s by the faster and more stable photodiodes and photoresistors. ROs are still used in some sound equipment, guitar amplifiers and analog synthesizers owing to their good electrical isolation, low signal distortion and ease of circuit design.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report