• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Analog Input / Output Modules
Analog Input / Output Modules

KT88 – TRIODE Parallel Push-Pull 60Watt Mono
KT88 – TRIODE Parallel Push-Pull 60Watt Mono

... KT88 - (TRIODE) PARALLEL PUSH-PULL 60WATT AMPLIFIER explains and demonstrates that the THD dip is due to reversal of the relative phase of the signal current in the active load to that delivered to the subsequent grid leak. This causes the proportions of the 2nd, 3rd and 4th harmonics to change. Ge ...
Very wide input voltage range 6 W SMPS for metering
Very wide input voltage range 6 W SMPS for metering

... To keep the transformer size very small and to get a very effective cost solution, we prefer to slightly increase the minimum working frequency in order to decrease the primary inductance. In order to have a 15 mH inductance and to keep an EF20 core, a lot of turns are needed on the primary side. Th ...
Chaos rules! Chapter 20
Chaos rules! Chapter 20

... period is T we find that the output pattern must repeat after a time of, at most, T 0 = 2n T . This is because the system will have then ‘cycled through’ all the possible bit patterns it can store and must then repeat a previous state. The digital system therefore behaves like an analog system which ...
Controller Schematic Design
Controller Schematic Design

FSL156MRIN Green-Mode Fairchild Power Switch (FPS™) FSL156MRIN — Green-Mode Fair
FSL156MRIN Green-Mode Fairchild Power Switch (FPS™) FSL156MRIN — Green-Mode Fair

... 4.1 Overload Protection (OLP): Overload is defined as the load current exceeding its normal level due to an unexpected abnormal event. In this situation, the protection circuit should trigger to protect the SMPS. However, even when the SMPS is in normal operation, the overload protection circuit can ...
Dual Differential Line Driver With 3-State Outputs
Dual Differential Line Driver With 3-State Outputs

... drive nor load the bus. This permits many devices to be connected together on the same transmission line for ...
UCN5804 - Allegro Microsystems
UCN5804 - Allegro Microsystems

High Performance Charge Pump Converter with Integrated CMOS
High Performance Charge Pump Converter with Integrated CMOS

IX3120 - IXYS Integrated Circuits Division
IX3120 - IXYS Integrated Circuits Division

... • 25kV/µs Minimum Common Mode Rejection (CMR) at 1500VCM • Wide Operating Voltage Range: 15V to 30V • Under Voltage Lockout with Hysteresis • 3750Vrms Input to Output Isolation • Wide Temperature Range: -40°C to +100°C ...
Document
Document

... This time each pixel on the picture consists of only ground or only aerial voltages. The ground mode information corresponds to RED while the aerial mode information corresponds to GREEN. In both cases remaining two color channels are 0 for all pixels. ...
Digital Current Mode Control for Buck
Digital Current Mode Control for Buck

T34123128
T34123128

... distribution system have numerous nonlinear loads, which are significantly affecting the quality of power supply. As a result, the purity of waveform of supply lost. This ends up producing many power quality problems [1]. ...
Mega Beast Product Demonstration
Mega Beast Product Demonstration

... Continuous or sporadic distortions of the 60-hertz (Hz) voltage sine waveform, usually caused by microprocessor based loads in the building such as computer power supplies, lighting ballasts, and electronic adjustable speed drives. Harmonics can also be transmitted from an energy user down the block ...
Testing Power Sources for Stability
Testing Power Sources for Stability

CH26 LAB Capacitors
CH26 LAB Capacitors

25471_energy_conversion_9
25471_energy_conversion_9

Visio-ALD-214012PJ132 (CTR-4474-X) Instruction - TDK
Visio-ALD-214012PJ132 (CTR-4474-X) Instruction - TDK

... ●This product is designed for driving LED backlight systems. Do not use it with any other load. ●Store this product under the conditions defined in the specification document. ●Do not store this product in an environment where dust, dirt or corrosive gas(salt,acid,base, etc.) is present. ●This produ ...
Journal of Applied Science and Agriculture
Journal of Applied Science and Agriculture

... In this proposed circuit the -3dB cut-off frequencies for voltage and current transfer functions are 3.87GHz and 3.23GHz respectively. The specific of high frequency performances of proposed CCII can able it for using in analog RF components. The Proposed CCII-based Oscillator: Recently, oscillators ...
DC Motors
DC Motors

... Large AC generator •Unlike our generator model with a fixed magnetic field and rotating armature, it is more practical to fix the armature windings and rotate the magnetic field on large generators. •Brushes and slip rings pass EXCITATION voltage to the field windings on the rotor to create the mag ...
AC Circuits - GTU e
AC Circuits - GTU e

... resistance, and its voltage and current are in phase. If the resistance is small, the current may be quite large. ...
AN2117
AN2117

... The RSENSE resistor set the input peak current value. Of course, the input peak current value selected have to be lower than the power supply current capability limit. In typical application the input peak current is fixed to 900mApK (100mV / 110mΩ) in order to guarantee a proper performances in the ...
LM117/LM317A/LM317 3-Terminal Adjustable Regulator
LM117/LM317A/LM317 3-Terminal Adjustable Regulator

... regulators is capable of supplying in excess of 1.5A over a 1.2V to 37V output range. They are exceptionally easy to use and require only two external resistors to set the output voltage. Further, both line and load regulation are better than standard fixed regulators. Also, the LM117 is packaged in ...
max17552atbevkit - Part Number Search
max17552atbevkit - Part Number Search

... The MAX17552 5V EV kit (TDFN) is a fully assembled and tested circuit board that demonstrates the performance of the MAX17552 60V, 100mA ultra-small, high-efficiency, synchronous step-down DC-DC converter in a 10-pin TDFN package. The EV kit operates over a wide input voltage range of 6V to 60V and ...
1ACMeasure
1ACMeasure

< 1 ... 644 645 646 647 648 649 650 651 652 ... 1099 >

Voltage regulator



A voltage regulator is designed to automatically maintain a constant voltage level. A voltage regulator may be a simple ""feed-forward"" design or may include negative feedback control loops. It may use an electromechanical mechanism, or electronic components. Depending on the design, it may be used to regulate one or more AC or DC voltages.Electronic voltage regulators are found in devices such as computer power supplies where they stabilize the DC voltages used by the processor and other elements. In automobile alternators and central power station generator plants, voltage regulators control the output of the plant. In an electric power distribution system, voltage regulators may be installed at a substation or along distribution lines so that all customers receive steady voltage independent of how much power is drawn from the line.