MAX5082/MAX5083 1.5A, 40V, MAXPower Step-Down DC-DC Converters General Description
... MAX5082 and 7.5V to 40V for the MAX5083. The output is adjustable from 1.23V to 32V and can deliver up to 1.5A of load current. Both devices utilize a voltage-mode control scheme for good noise immunity in the high-voltage switching environment and offer external compensation allowing for maximum fl ...
... MAX5082 and 7.5V to 40V for the MAX5083. The output is adjustable from 1.23V to 32V and can deliver up to 1.5A of load current. Both devices utilize a voltage-mode control scheme for good noise immunity in the high-voltage switching environment and offer external compensation allowing for maximum fl ...
NE2322092216
... Space Vector modulation (SVM) has recently grown as a very popular pulse width modulation (PWM) method for voltage – source inverters because of its very good harmonic quality and extended linear range of operation [1]. However, a drawback of SVM is that it requires complex online computation that u ...
... Space Vector modulation (SVM) has recently grown as a very popular pulse width modulation (PWM) method for voltage – source inverters because of its very good harmonic quality and extended linear range of operation [1]. However, a drawback of SVM is that it requires complex online computation that u ...
Installing RC Equipment in Larger Aircraft pdf file
... switches into a Y-harness or two servo ports on the receiver. Simply plugging in two batteries into one receiver may look attractive at first, but it really only protects against the rare case when one of the batteries or switches fails open-circuit. But, NiCd’s predominantly fail in short-circuit, ...
... switches into a Y-harness or two servo ports on the receiver. Simply plugging in two batteries into one receiver may look attractive at first, but it really only protects against the rare case when one of the batteries or switches fails open-circuit. But, NiCd’s predominantly fail in short-circuit, ...
Installation Guide Contents
... no need for a computer to configurate the controller. The unit can either be handheld or fixed format and will come complete with a cradle for the keypad. The main control unit can be mounted elsewhere in the vehicle and is linked to the keypad via a standard RJ45 connector system (a 5metre RJ45 ext ...
... no need for a computer to configurate the controller. The unit can either be handheld or fixed format and will come complete with a cradle for the keypad. The main control unit can be mounted elsewhere in the vehicle and is linked to the keypad via a standard RJ45 connector system (a 5metre RJ45 ext ...
Product Specifications VC-6000 Monitoring System Monitoring Module – SM-610-160
... 2x Vibration (2x User-defined Bandwidth, 4x Tracking Filter), 2x Speed Channels, 6x DC Outputs, 8x Relays The VC-6000 Monitoring System hardware is used for both stand-alone safety monitoring and condition monitoring using the Compass 6000 monitoring software modules and database. The VC-6000 offers ...
... 2x Vibration (2x User-defined Bandwidth, 4x Tracking Filter), 2x Speed Channels, 6x DC Outputs, 8x Relays The VC-6000 Monitoring System hardware is used for both stand-alone safety monitoring and condition monitoring using the Compass 6000 monitoring software modules and database. The VC-6000 offers ...
DS90LV047A 3V LVDS Quad CMOS Differential Line Driver DS90L V047A
... current for a range of loads (a voltage mode driver on the other hand supplies a constant voltage for a range of loads). Current is switched through the load in one direction to produce a logic state and in the other direction to produce the other logic state. The output current is typically 3.1 mA, ...
... current for a range of loads (a voltage mode driver on the other hand supplies a constant voltage for a range of loads). Current is switched through the load in one direction to produce a logic state and in the other direction to produce the other logic state. The output current is typically 3.1 mA, ...
Teacher`s Guide - Activity P48: Transformer
... A transformer can be used to increase or decrease AC voltages. An AC voltage is applied to the primary coil of a transformer, which is surrounded by the secondary coil but is not electrically connected to it. The primary coil produces a changing magnetic flux through the secondary coil, which will i ...
... A transformer can be used to increase or decrease AC voltages. An AC voltage is applied to the primary coil of a transformer, which is surrounded by the secondary coil but is not electrically connected to it. The primary coil produces a changing magnetic flux through the secondary coil, which will i ...
Encoders Frequently Asked Questions
... electrical noise. This includes AC motors, arc welders, AC power lines, and transformers. Use twisted pair cabling when using the signal and its compliment, and shielded cabling when running any type of signal. Use the highest voltage available for the output voltage. For example, if the encoder wil ...
... electrical noise. This includes AC motors, arc welders, AC power lines, and transformers. Use twisted pair cabling when using the signal and its compliment, and shielded cabling when running any type of signal. Use the highest voltage available for the output voltage. For example, if the encoder wil ...
MAX78700 Multichannel, Isolated, Precision ADC General Description Benefits and Features
... Output of the Rectifier Block ...
... Output of the Rectifier Block ...
LAB 1 - Northwestern Mechatronics Wiki
... motor to ground. For sufficiently negative values of the input voltage, the TIP32 pnp transistor will turn on, and the output voltage will be one diode drop higher than the input voltage. Current flows from ground through the motor to the –12V supply. ...
... motor to ground. For sufficiently negative values of the input voltage, the TIP32 pnp transistor will turn on, and the output voltage will be one diode drop higher than the input voltage. Current flows from ground through the motor to the –12V supply. ...
Alternating Current (AC) Circuits
... capacitor is discharging, so the voltage across it decreases (d to f ). When the voltage across the capacitor is zero (point f ), the current is at its maximum as charge is free to move in the circuit. The remainder of the cycle is the same as the first half, but for current moving in the opposite d ...
... capacitor is discharging, so the voltage across it decreases (d to f ). When the voltage across the capacitor is zero (point f ), the current is at its maximum as charge is free to move in the circuit. The remainder of the cycle is the same as the first half, but for current moving in the opposite d ...
AiT Semiconductor Inc. AiT Semiconductor Inc. DESCRIPTION
... signals, or adding a switched resistor in parallel with RSET. The enable input pin allows the A8440 to be placed in power-down mode. The A8440 is available in 16pin TQFN (3x3mm) ...
... signals, or adding a switched resistor in parallel with RSET. The enable input pin allows the A8440 to be placed in power-down mode. The A8440 is available in 16pin TQFN (3x3mm) ...
FAN6862R / FAN6862L Highly Integrated Green-Mode PWM Controller
... The FAN6862R/L has an internal soft-start circuit that increases pulse-by-pulse current-limit comparator inverting input voltage slowly after it starts. The typical soft-start time is 5ms. The pulsewidth to the power MOSFET is progressively increased to establish the correct working conditions for t ...
... The FAN6862R/L has an internal soft-start circuit that increases pulse-by-pulse current-limit comparator inverting input voltage slowly after it starts. The typical soft-start time is 5ms. The pulsewidth to the power MOSFET is progressively increased to establish the correct working conditions for t ...
Wireless Bluetooth Controller For DC Motor
... @ 2 RPM: Duty cycle = 110 @ 108 RPM: Duty cycle = 950 Y = mx + b Duty = 7.92(speed) + 94.15 ...
... @ 2 RPM: Duty cycle = 110 @ 108 RPM: Duty cycle = 950 Y = mx + b Duty = 7.92(speed) + 94.15 ...
A5973D Datasheet - STMicroelectronics
... internal reference (VREF) so a small filtering capacitor (100 nF) connected between VREF pin and the signal ground of the master device is suggested for its proper operation. However when a set of synchronized devices populates a board it is not possible to know in advance the one working as maste ...
... internal reference (VREF) so a small filtering capacitor (100 nF) connected between VREF pin and the signal ground of the master device is suggested for its proper operation. However when a set of synchronized devices populates a board it is not possible to know in advance the one working as maste ...
ADP5033 英文数据手册DataSheet 下载
... portable devices. The ADP5033 LDOs maintain power supply rejection greater than 60 dB for frequencies as high as 10 kHz while operating with a low headroom voltage. ...
... portable devices. The ADP5033 LDOs maintain power supply rejection greater than 60 dB for frequencies as high as 10 kHz while operating with a low headroom voltage. ...
factor Form Value RMS value Average
... Explanation of speed control of induction motor by VFD (Variable frequency Drive): The synchronous speed of the induction motor can be varied smoothly over a wide range by changing the supply frequency. In order to maintain the air gap flux at its normal value under varying frequency conditions, ...
... Explanation of speed control of induction motor by VFD (Variable frequency Drive): The synchronous speed of the induction motor can be varied smoothly over a wide range by changing the supply frequency. In order to maintain the air gap flux at its normal value under varying frequency conditions, ...
Voltage regulator
A voltage regulator is designed to automatically maintain a constant voltage level. A voltage regulator may be a simple ""feed-forward"" design or may include negative feedback control loops. It may use an electromechanical mechanism, or electronic components. Depending on the design, it may be used to regulate one or more AC or DC voltages.Electronic voltage regulators are found in devices such as computer power supplies where they stabilize the DC voltages used by the processor and other elements. In automobile alternators and central power station generator plants, voltage regulators control the output of the plant. In an electric power distribution system, voltage regulators may be installed at a substation or along distribution lines so that all customers receive steady voltage independent of how much power is drawn from the line.