ZXSC410/ZXSC420/ZXSC440 Description Pin Assignments
... operation, when the voltage at the STDN pin is between 1V and 8V (and also open circuit). The ZXSC410/440 is shutdown with the driver disabled when the voltage at the STDN pin is 0.7V or lower. The STDN input is a high impedance current source of 1µA typ. The driving device can be an open-collector ...
... operation, when the voltage at the STDN pin is between 1V and 8V (and also open circuit). The ZXSC410/440 is shutdown with the driver disabled when the voltage at the STDN pin is 0.7V or lower. The STDN input is a high impedance current source of 1µA typ. The driving device can be an open-collector ...
Series C / B 3700
... Module is designed for installation to a structure or within a cabinet. Screw type mating connectors are supplied with the module. Due to the limited number of connector pins this option is not available for modules with dual AC input. Option is avalaible for currents up to 60Amps. ...
... Module is designed for installation to a structure or within a cabinet. Screw type mating connectors are supplied with the module. Due to the limited number of connector pins this option is not available for modules with dual AC input. Option is avalaible for currents up to 60Amps. ...
Experiment 7: RC Circuits
... reads exactly 9 V (i.e. Vo = 9V ) record the time from the second column of the table on your data sheet. Then record subsequent times for voltages from 8.0 V- 2.0 V in one volt increments, subtracting to find the elapsed times. Recharge the capacitor and repeat as often as necessary. Create a two-c ...
... reads exactly 9 V (i.e. Vo = 9V ) record the time from the second column of the table on your data sheet. Then record subsequent times for voltages from 8.0 V- 2.0 V in one volt increments, subtracting to find the elapsed times. Recharge the capacitor and repeat as often as necessary. Create a two-c ...
MC100LVEL14 - 3.3 V ECL 1:5 Clock Distribution Chip
... device can be driven by either a differential or single-ended ECL or, if positive power supplies are used, PECL input signal. The LVEL14 is functionally and pin compatible with the EL14 but is designed to operate in ECL or PECL mode for a voltage supply range of −3.0 V to −3.8 V ( or 3.0 V to 3.8 V) ...
... device can be driven by either a differential or single-ended ECL or, if positive power supplies are used, PECL input signal. The LVEL14 is functionally and pin compatible with the EL14 but is designed to operate in ECL or PECL mode for a voltage supply range of −3.0 V to −3.8 V ( or 3.0 V to 3.8 V) ...
1. Introduction
... be the same as on substation 138kV bus j, except for possible zero-sequence component blocking and positive/negative-phase shifts. The significance of the above paragraph is that for transmission faults, one monitor at either the substation 138kV bus or at the substation 12.47kV bus is adequate to p ...
... be the same as on substation 138kV bus j, except for possible zero-sequence component blocking and positive/negative-phase shifts. The significance of the above paragraph is that for transmission faults, one monitor at either the substation 138kV bus or at the substation 12.47kV bus is adequate to p ...
Tunable Sensors for Process-Aware Voltage Scaling
... Default config. • Low resistance passgates • Guardband for worst-case • Vmin_est > Vmin_chip • 13mV margin ...
... Default config. • Low resistance passgates • Guardband for worst-case • Vmin_est > Vmin_chip • 13mV margin ...
28 VOLT INPUT - Crane Interpoint
... input voltage range of 16 to 40 volts (19 to 40 volts for 15 volt output models). Operation below 16 volts (or below 19 volts for the 15 volt output models), including operation in MIL-STD-704E emergency power conditions, is possible with derated output power. Please refer to the low voltage drop-ou ...
... input voltage range of 16 to 40 volts (19 to 40 volts for 15 volt output models). Operation below 16 volts (or below 19 volts for the 15 volt output models), including operation in MIL-STD-704E emergency power conditions, is possible with derated output power. Please refer to the low voltage drop-ou ...
HMC856LC5 数据资料DataSheet下载
... All differential inputs to the HMC856LC5 are CML and terminated on-chip with 50 Ohms to the positive supply, GND, and may be AC or DC coupled. The differential CML outputs are source terminated to 50 Ohms and may also be AC or DC coupled. Outputs can be connected directly to a 50 Ohm ground terminat ...
... All differential inputs to the HMC856LC5 are CML and terminated on-chip with 50 Ohms to the positive supply, GND, and may be AC or DC coupled. The differential CML outputs are source terminated to 50 Ohms and may also be AC or DC coupled. Outputs can be connected directly to a 50 Ohm ground terminat ...
EMIF07-LCD03F3
... Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notic ...
... Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notic ...
How to select a VFD
... manufacturers have recommended operation speed ranges for their motors. Operation restrictions on the turndown of the equipment connected to the motor should reflect these operation speed range recommendations. As stated earlier, IGBTs can switch on and off extremely fast. The speed with which they ...
... manufacturers have recommended operation speed ranges for their motors. Operation restrictions on the turndown of the equipment connected to the motor should reflect these operation speed range recommendations. As stated earlier, IGBTs can switch on and off extremely fast. The speed with which they ...
LIGHTNING PROTECTION TELECONMSTEXT
... clamping level of the arrester. The VPL of an arrester is directly related to the reaction time of the arrester ie: the faster the reaction time, the lower the VPL. In many cases, the transient is lower in voltage than the VPL of the arrester, or faster than the arrester’s reaction time. The arreste ...
... clamping level of the arrester. The VPL of an arrester is directly related to the reaction time of the arrester ie: the faster the reaction time, the lower the VPL. In many cases, the transient is lower in voltage than the VPL of the arrester, or faster than the arrester’s reaction time. The arreste ...
Square Body Flush End
... Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been ...
... Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been ...
AN2118
... Operation in off-hook condition A major feature of this device is that when changing from on-hook to off-hook conditions (IL >0 mA), the VBAT voltage is automatically adjusted depending on the loop resistance and on the programmed current limitation value (ILIM). It should be noted that the device i ...
... Operation in off-hook condition A major feature of this device is that when changing from on-hook to off-hook conditions (IL >0 mA), the VBAT voltage is automatically adjusted depending on the loop resistance and on the programmed current limitation value (ILIM). It should be noted that the device i ...
MOS Charge Pumps for Low-Voltage Operation - Solid
... HARGE pumps are circuits that can pump charge upward to produce voltages higher than the regular supply voltage. Charge pumps have been used in the nonvolatile memories, such as EEPROM and Flash memories, for the programming of the floating-gate devices [1], [2]. They can also be used in the low-sup ...
... HARGE pumps are circuits that can pump charge upward to produce voltages higher than the regular supply voltage. Charge pumps have been used in the nonvolatile memories, such as EEPROM and Flash memories, for the programming of the floating-gate devices [1], [2]. They can also be used in the low-sup ...
International Electrical Engineering Journal (IEEJ) Vol. 5 (2014) No.12, pp. 1703-1710
... different feeders in a distribution system. In [9], a configuration called IDVR has been discussed in which two DVRs are connected in series with two separate adjacent feeders. The dc buses of the DVRs are connected together. The IDVR absorbs real power from one feeder and maintains the dc link volt ...
... different feeders in a distribution system. In [9], a configuration called IDVR has been discussed in which two DVRs are connected in series with two separate adjacent feeders. The dc buses of the DVRs are connected together. The IDVR absorbs real power from one feeder and maintains the dc link volt ...
AT-250 Voltage Variable Absorptive Attenuator 12 dB, DC - 2.0 GHz
... Low Intermodulation Products Low DC Power Consumption: 50 μW Single Voltage Control: 0 to -4 Volts Nanosecond Switching Speed Temperature Range: -40°C to +85°C SOIC-8 Plastic Package Tape and Reel Packaging Available ...
... Low Intermodulation Products Low DC Power Consumption: 50 μW Single Voltage Control: 0 to -4 Volts Nanosecond Switching Speed Temperature Range: -40°C to +85°C SOIC-8 Plastic Package Tape and Reel Packaging Available ...
PM-24-80 Power Module
... that are subject to nearby lightning strikes or transients caused by nearby motor contactors, air conditioning compressors, etc. ...
... that are subject to nearby lightning strikes or transients caused by nearby motor contactors, air conditioning compressors, etc. ...
EPF 230V/16A-S EPF 230V/35A-S
... Ohms resistant, inductive resistant (differential mode and common mode filter). By these, a low-pass behaviour is achieved. The SPDs are fitted with a thermal protection NC contact, which respond if the varistor exceed a certain level of temperature due to thermal overload. These thermal protection ...
... Ohms resistant, inductive resistant (differential mode and common mode filter). By these, a low-pass behaviour is achieved. The SPDs are fitted with a thermal protection NC contact, which respond if the varistor exceed a certain level of temperature due to thermal overload. These thermal protection ...
File tda1562 | allcomponents.ru
... When a short-circuit occurs at the outputs to ground or to the supply voltage, the output stages are switched off. They will be switched on again approximately 20 ms after removing the short-circuit. During this short-circuit condition the diagnostic output is continuously LOW. When a short-circuit ...
... When a short-circuit occurs at the outputs to ground or to the supply voltage, the output stages are switched off. They will be switched on again approximately 20 ms after removing the short-circuit. During this short-circuit condition the diagnostic output is continuously LOW. When a short-circuit ...
ANSI_ SCTE 46 2002R2007
... Use a DVM (item #7) in series with the DC output or the electronic load ammeter (item #4) may also be used. If the power supply being tested has multiple DC voltage outputs adjust each DC output to the specified maximum output load current. Readjust the input AC voltage if it has changed. 4.1.3. Usi ...
... Use a DVM (item #7) in series with the DC output or the electronic load ammeter (item #4) may also be used. If the power supply being tested has multiple DC voltage outputs adjust each DC output to the specified maximum output load current. Readjust the input AC voltage if it has changed. 4.1.3. Usi ...
Specification Sheet
... Capable of producing 115dB @ 10 feet and with a range of prerecorded tones, the DB3B includes an integral volume control, which is ideal when a lower output is required. The unit is provided with versatile control options allowing compatibility with a wide range of control methods and PLCs. The stan ...
... Capable of producing 115dB @ 10 feet and with a range of prerecorded tones, the DB3B includes an integral volume control, which is ideal when a lower output is required. The unit is provided with versatile control options allowing compatibility with a wide range of control methods and PLCs. The stan ...
LB3419962001
... insulated-gate bipolar transistors, which are driven by phase-shift control. The secondary side is composed of a resonant tank and a half-wave rectifier. Without an auxiliary circuit, zerovoltage switching (for leading-leg switches) and zero-current switching (for lagging-leg switches) are achieved ...
... insulated-gate bipolar transistors, which are driven by phase-shift control. The secondary side is composed of a resonant tank and a half-wave rectifier. Without an auxiliary circuit, zerovoltage switching (for leading-leg switches) and zero-current switching (for lagging-leg switches) are achieved ...
Voltage regulator
A voltage regulator is designed to automatically maintain a constant voltage level. A voltage regulator may be a simple ""feed-forward"" design or may include negative feedback control loops. It may use an electromechanical mechanism, or electronic components. Depending on the design, it may be used to regulate one or more AC or DC voltages.Electronic voltage regulators are found in devices such as computer power supplies where they stabilize the DC voltages used by the processor and other elements. In automobile alternators and central power station generator plants, voltage regulators control the output of the plant. In an electric power distribution system, voltage regulators may be installed at a substation or along distribution lines so that all customers receive steady voltage independent of how much power is drawn from the line.