MAX3397E Dual Bidirectional Low-Level Translator in µDFN General Description
... and VL, set the logic levels on either side of the device. A logic-low signal present on the VL side of the device appears as a logic-low signal on the VCC side of the device, and vice versa. The MAX3397E utilizes a transmission-gate-based design to allow data translation in either direction (VL ↔ V ...
... and VL, set the logic levels on either side of the device. A logic-low signal present on the VL side of the device appears as a logic-low signal on the VCC side of the device, and vice versa. The MAX3397E utilizes a transmission-gate-based design to allow data translation in either direction (VL ↔ V ...
High-Performance Phase-Locked Loop (Rev. B)
... Continuous total power dissipation at (or below) TA = 25°C (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . 700 mW Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −20°C to 75°C Storage temperature range, Tstg ...
... Continuous total power dissipation at (or below) TA = 25°C (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . 700 mW Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −20°C to 75°C Storage temperature range, Tstg ...
Electronics 123
... The products that are advertised in this new catalogue can be purchased at our shop. You are invited to visit our shop and see the products firsthand, however for your convenience all the products may also be ordered from our website. Electronics123 is a well-established company providing a service ...
... The products that are advertised in this new catalogue can be purchased at our shop. You are invited to visit our shop and see the products firsthand, however for your convenience all the products may also be ordered from our website. Electronics123 is a well-established company providing a service ...
... the oscillator to an external source that is either slower of faster than the nominal free running oscillator frequency. To use the SYNC function, VSET pin should be pulled up to BP3 or set the FORCE_SYNC bit in register MISC_CONFIG_OPTIONS (MFR_SPECIFIC_32) (F0h) if VSET function is used; if synchr ...
4.5-V to 18-V, 20-A and 30-A SWIFT
... the oscillator to an external source that is either slower of faster than the nominal free running oscillator frequency. To use the SYNC function, VSET pin should be pulled up to BP3 or set the FORCE_SYNC bit in register MISC_CONFIG_OPTIONS (MFR_SPECIFIC_32) (F0h) if VSET function is used; if synchr ...
... the oscillator to an external source that is either slower of faster than the nominal free running oscillator frequency. To use the SYNC function, VSET pin should be pulled up to BP3 or set the FORCE_SYNC bit in register MISC_CONFIG_OPTIONS (MFR_SPECIFIC_32) (F0h) if VSET function is used; if synchr ...
IP4788CZ32
... and help reducing impedance discontinuities. All TMDS lines are protected by an impedance-matched diode configuration that minimizes impedance discontinuities caused by typical shunt diodes. The enhanced 60 mA overcurrent / overvoltage linear regulator guarantees HDMI-compliant 5 V output voltage le ...
... and help reducing impedance discontinuities. All TMDS lines are protected by an impedance-matched diode configuration that minimizes impedance discontinuities caused by typical shunt diodes. The enhanced 60 mA overcurrent / overvoltage linear regulator guarantees HDMI-compliant 5 V output voltage le ...
Reference Divider
... procedure requires a stable source and a null detector. The 752A is a ratio device only, and does not have to be included in a calibration cycle that is traceable to an external standard. 1-4. The front panel MODE switch selects betweenselfcalibration and normal operation. In the Self-Calibration mo ...
... procedure requires a stable source and a null detector. The 752A is a ratio device only, and does not have to be included in a calibration cycle that is traceable to an external standard. 1-4. The front panel MODE switch selects betweenselfcalibration and normal operation. In the Self-Calibration mo ...
0.9 Mb PDF - David Kleinfeld
... We return to the load line equation, which is reordered as The load line for ID versus VDS is found by computing the voltage drops along the loop, i.e., IDS = ...
... We return to the load line equation, which is reordered as The load line for ID versus VDS is found by computing the voltage drops along the loop, i.e., IDS = ...
3 - Schneider Electric België
... b phase protection and earth fault protection with adjustable reset time, with switching of the active group of settings and logic discrimination b earth fault protection insensitive to transformer switching b RMS thermal overload protection that takes into account external operating temperature and ...
... b phase protection and earth fault protection with adjustable reset time, with switching of the active group of settings and logic discrimination b earth fault protection insensitive to transformer switching b RMS thermal overload protection that takes into account external operating temperature and ...
gesis ELECTRONIC - Wieland Electric Inc.
... internal bus contact automatically when the modules are combined. In-between feed-in modules allow separate fuses for different functions. Because of the flat shape, the connection from one side, well-thought-out mounting options and the modular concept of this system fits in almost any space. The s ...
... internal bus contact automatically when the modules are combined. In-between feed-in modules allow separate fuses for different functions. Because of the flat shape, the connection from one side, well-thought-out mounting options and the modular concept of this system fits in almost any space. The s ...
74HC4851; 74HCT4851 1. General description 8-channel analog multiplexer/demultiplexer with
... inputs/outputs (Y0 to Y7) and a common input/output (Z). The devices feature injection-current effect control, which has excellent value in automotive applications where voltages in excess of the supply voltage are common. With E LOW, one of the eight switches is selected (low impedance ON-state) by ...
... inputs/outputs (Y0 to Y7) and a common input/output (Z). The devices feature injection-current effect control, which has excellent value in automotive applications where voltages in excess of the supply voltage are common. With E LOW, one of the eight switches is selected (low impedance ON-state) by ...
spastyle - IEEE Standards working groups
... Overhead Contact System (OCS) from transient overvoltages associated with lightning and switching surges. Switching surges are inherent characteristics of electrification system and are generally considered low energy transient overvoltages. Lightning surges are natural, caused by electrical dischar ...
... Overhead Contact System (OCS) from transient overvoltages associated with lightning and switching surges. Switching surges are inherent characteristics of electrification system and are generally considered low energy transient overvoltages. Lightning surges are natural, caused by electrical dischar ...
Ch4. LLC Resonant Converter
... 300V. At high input voltage, the converter is working at higher frequency far away from resonant frequency. Same as PRC and SRC, the circulating energy and turn off current of MOSFET also increase at high input voltage. The turn off current is more than 10A. With above analysis, we can see that SPRC ...
... 300V. At high input voltage, the converter is working at higher frequency far away from resonant frequency. Same as PRC and SRC, the circulating energy and turn off current of MOSFET also increase at high input voltage. The turn off current is more than 10A. With above analysis, we can see that SPRC ...
Basic Electricity & Electronics IT 1011 for
... (a) What type of circuit is this? (b) What is the total peak secondary voltage? (c) Find the peak voltage across each half of the secondary. (d) Sketch the voltage wave form across RL. (e) What is the peak current through each diode? (f) What is the PIV for each diode? 6. Determine the output voltag ...
... (a) What type of circuit is this? (b) What is the total peak secondary voltage? (c) Find the peak voltage across each half of the secondary. (d) Sketch the voltage wave form across RL. (e) What is the peak current through each diode? (f) What is the PIV for each diode? 6. Determine the output voltag ...
www.colehersee.com.au
... In a dual battery system, one battery is used for starting the engine while the other is used to power auxiliary loads. A battery selector switch enables the use of the first battery, the second battery or both batteries simultaneously. A dual battery system with a battery selector switch provides b ...
... In a dual battery system, one battery is used for starting the engine while the other is used to power auxiliary loads. A battery selector switch enables the use of the first battery, the second battery or both batteries simultaneously. A dual battery system with a battery selector switch provides b ...
MAX9311/MAX9313 1:10 Differential LVPECL/LVECL/HSTL Clock and Data Drivers General Description
... The MAX9311/MAX9313 are low skew, 1-to-10 differential drivers designed for clock and data distribution. A 2:1 mux selects between the two differential inputs, CLK0, CLK0 and CLK1, CLK1. The 2:1 mux is switched by the single-ended CLKSEL input. A logic low selects the CLK0, CLK0 input. A logic high ...
... The MAX9311/MAX9313 are low skew, 1-to-10 differential drivers designed for clock and data distribution. A 2:1 mux selects between the two differential inputs, CLK0, CLK0 and CLK1, CLK1. The 2:1 mux is switched by the single-ended CLKSEL input. A logic low selects the CLK0, CLK0 input. A logic high ...
Switchmode Power Supply Handbook, Third Edition
... All trademarks are trademarks of their respective owners. Rather than put a trademark symbol after every occurrence of a trademarked name, we use names in an editorial fashion only, and to the benefit of the trademark owner, with no intention of infringement of the trademark. Where such designations ...
... All trademarks are trademarks of their respective owners. Rather than put a trademark symbol after every occurrence of a trademarked name, we use names in an editorial fashion only, and to the benefit of the trademark owner, with no intention of infringement of the trademark. Where such designations ...
MAX6315 Open-Drain SOT µP Reset Circuit ________________General Description ____________________________Features
... known state. The MAX6315 asserts reset to prevent code-execution errors during power-up, powerdown, or brownout conditions. RESET is guaranteed to be a logic-low for V CC > 1V (see the Electrical Characteristics table). Once VCC exceeds the reset threshold, the internal timer keeps reset asserted fo ...
... known state. The MAX6315 asserts reset to prevent code-execution errors during power-up, powerdown, or brownout conditions. RESET is guaranteed to be a logic-low for V CC > 1V (see the Electrical Characteristics table). Once VCC exceeds the reset threshold, the internal timer keeps reset asserted fo ...
Voltage regulator
A voltage regulator is designed to automatically maintain a constant voltage level. A voltage regulator may be a simple ""feed-forward"" design or may include negative feedback control loops. It may use an electromechanical mechanism, or electronic components. Depending on the design, it may be used to regulate one or more AC or DC voltages.Electronic voltage regulators are found in devices such as computer power supplies where they stabilize the DC voltages used by the processor and other elements. In automobile alternators and central power station generator plants, voltage regulators control the output of the plant. In an electric power distribution system, voltage regulators may be installed at a substation or along distribution lines so that all customers receive steady voltage independent of how much power is drawn from the line.