• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
wrong cable size? how did you determine the maximum demand?
wrong cable size? how did you determine the maximum demand?

... maximum load. The problem is, how do you determine when the installation is at maximum load? Measurement may inadvertently be conducted during a period of lower consumption. For this reason, it is recommended that the electrical installation is monitored for a minimum of one week to give a true indi ...
Active-Clamped, Spread-Spectrum, Current-Mode PWM Controllers MAX5974A/MAX5974B/MAX5974C/MAX5974D EVALUATION KIT AVAILABLE
Active-Clamped, Spread-Spectrum, Current-Mode PWM Controllers MAX5974A/MAX5974B/MAX5974C/MAX5974D EVALUATION KIT AVAILABLE

... The MAX5974A/MAX5974B feature unique circuitry to achieve output regulation without using an optocoupler, while the MAX5974C/MAX5974D utilize the traditional optocoupler feedback method. An internal error amplifier with a 1% reference is very useful in nonisolated design, eliminating the need for an ...
Extend the I C-bus with advanced repeaters and hubs NXP 2-channel I
Extend the I C-bus with advanced repeaters and hubs NXP 2-channel I

... Alternatives are recommended to support special conditions. For systems with very low voltage (down to 0.9 V), use the PCA9508/ 09/17A/19. For systems with up to 1500 pF, use the PCA9507, which has a rise-time accelerator. For systems larger than four segments, use the PCA9518A. For systems with rep ...
RA30H0608M 数据资料DataSheet下载
RA30H0608M 数据资料DataSheet下载

... 2.RA series products (RF power amplifier modules) and RD series products (RF power transistors) are designed for consumer mobile communication terminals and were not specifically designed for use in other applications. In particular, while these products are highly reliable for their designed purpos ...
Automatic Voltage Regulator ECW500
Automatic Voltage Regulator ECW500

bq769x0 boot switch alternatives
bq769x0 boot switch alternatives

Phase Failure Relays
Phase Failure Relays

... condition independent of the motor’s running status. A current sensing device requires the motor to be running before an abnormal condition can be detected. Therefore, a voltage sensing device will provide pre-start protection while a current sensing device will not. Other advantages of voltage sens ...
ADM3485E 数据手册DataSheet 下载
ADM3485E 数据手册DataSheet 下载

... The transceivers are put into shutdown mode by bringing the RE high and the DE low. If the inputs are in this state for less than 80 ns, the parts are guaranteed not to enter shutdown. If the parts are in this state for 300 ns or more, the parts are guaranteed to enter shutdown. ...
LT1964 - 200mA, Low Noise, Low Dropout Negative Micropower
LT1964 - 200mA, Low Noise, Low Dropout Negative Micropower

... output capacitor of 1μF is required to prevent oscillations. Larger output capacitors will be required for applications with large transient loads to limit peak voltage transients. A parasitic diode exists between the output and the input. The output cannot be pulled more negative than the input dur ...
Technical Requirements for Connecting Small Scale PV (ssPV
Technical Requirements for Connecting Small Scale PV (ssPV

... 2.1.1. The quality of power provided by the ssPV systems is governed by practices and standards on voltage, flicker, frequency, harmonics and power factor at the PCC. 2.1.2. The ssPV shall be type approved. 2.1.3. Based that the system is operating with voltage variation in the range of ± 10% of the ...
ENHANCING FUEL BURNING EFFICIENCY BY REGULATE SPARK
ENHANCING FUEL BURNING EFFICIENCY BY REGULATE SPARK

AP1509  150KHz, 2A PWM BUCK DC/DC CONVERTER Description
AP1509 150KHz, 2A PWM BUCK DC/DC CONVERTER Description

... operating from damage, and current limit is against over current operating of the output switch. If current limit function occurs and VFB is down below 0.5V, the switching frequency ...
LTC6090(-5) - Linear Technology
LTC6090(-5) - Linear Technology

LTC3717 - Wide Operating Range, No Rsense Step
LTC3717 - Wide Operating Range, No Rsense Step

FEATURES DESCRIPTION D
FEATURES DESCRIPTION D

... requires approximately 400µs to achieve specified VOS accuracy, which includes one full auto-zero cycle of approximately 100µs and the start-up time for the bias circuitry. Prior to this time, the amplifier will function properly but with unspecified offset voltage. This design has virtually no alia ...
Lecture 2
Lecture 2

... In the case of tunnel diode the current i is a single valued function of the voltage v; consequently we can write i=f(v). Such a resistor is said to be voltage-controlled. On the other hand in the characteristic of gas tube the voltage v is a single valued function of the current i and we can write ...
RA13H4452M 数据资料DataSheet下载
RA13H4452M 数据资料DataSheet下载

... 2.RA series products (RF power amplifier modules) and RD series products (RF power transistors) are designed for consumer mobile communication terminals and were not specifically designed for use in other applications. In particular, while these products are highly reliable for their designed purpos ...
linear resistor
linear resistor

Digital Simulation of the Generalized Unified Power Flow Controller
Digital Simulation of the Generalized Unified Power Flow Controller

... (12-pulse) VSI, respectively, with the specified phase shift between all converters. For high-power applications with low distortion, the best option is the 48-pulse converter, although using parallel filters tuned to the 23th–25th harmonics with a 24-pulse converter could also be adequately attenti ...
- Gyanlo.com
- Gyanlo.com

NATF Load Modeling Practices
NATF Load Modeling Practices

... • The CMPLDW/CMLD model is NOT the “WECC” Model  It is generic, and can be used across the interconnections  Can provide detailed representation of dynamic load behavior, including induction motor loads  Must perform sensitivity studies to better understand model parameter impacts on performance ...
Electronic Components That Breakdown When Under Full Operating
Electronic Components That Breakdown When Under Full Operating

Logarithmic Representation of signal Levels “Decibel Notation dB”
Logarithmic Representation of signal Levels “Decibel Notation dB”

... dB expresses logarithmically the ratio between two signal levels (ex.: Vo/Vi = Gain) ...
220V-240V Pro line Product brochure
220V-240V Pro line Product brochure

utc tda2030a linear integrated circuit - Matthieu Benoit
utc tda2030a linear integrated circuit - Matthieu Benoit

< 1 ... 474 475 476 477 478 479 480 481 482 ... 1099 >

Voltage regulator



A voltage regulator is designed to automatically maintain a constant voltage level. A voltage regulator may be a simple ""feed-forward"" design or may include negative feedback control loops. It may use an electromechanical mechanism, or electronic components. Depending on the design, it may be used to regulate one or more AC or DC voltages.Electronic voltage regulators are found in devices such as computer power supplies where they stabilize the DC voltages used by the processor and other elements. In automobile alternators and central power station generator plants, voltage regulators control the output of the plant. In an electric power distribution system, voltage regulators may be installed at a substation or along distribution lines so that all customers receive steady voltage independent of how much power is drawn from the line.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report