TMP01 数据手册DataSheet 下载
... The accuracy of the VPTAT sensor output is well characterized and specified; however, preserving this accuracy in a heating or cooling control system requires some attention to minimizing the various potential error sources. The internal sources of setpoint programming error include the initial tole ...
... The accuracy of the VPTAT sensor output is well characterized and specified; however, preserving this accuracy in a heating or cooling control system requires some attention to minimizing the various potential error sources. The internal sources of setpoint programming error include the initial tole ...
Zetex - ZXFV4583 Sync separator with variable filter datasheet
... lines). Sample-and-hold circuits are used to obtain time-delayed voltage values of the sync tip and the back porch. The sample gates are controlled by a comparator sensing the video input relative to a threshold at a fixed offset above the sync tip clamp level. The sampled voltages are combined in a ...
... lines). Sample-and-hold circuits are used to obtain time-delayed voltage values of the sync tip and the back porch. The sample gates are controlled by a comparator sensing the video input relative to a threshold at a fixed offset above the sync tip clamp level. The sampled voltages are combined in a ...
... converter was extended further and some new multilevel topologies were proposed. The floating- or flying-capacitor multilevel converter is a more recent alternative topology where capacitors are used directly to clamp the voltages of the switch-chain nodes. Present interest in the circuit stems from ...
Understanding Arrester Discharge Voltage
... All arresters provide protection to equipment by limiting the voltage across the equipment terminals in the presence of a surge on the system. This voltage limiting characteristic of arresters is the primary feature of an arrester in most cases, and the reason for its existence. The voltage limiting ...
... All arresters provide protection to equipment by limiting the voltage across the equipment terminals in the presence of a surge on the system. This voltage limiting characteristic of arresters is the primary feature of an arrester in most cases, and the reason for its existence. The voltage limiting ...
STM1061
... The STM1061 low power voltage detector provides monitoring of battery, power-supply, and regulated system voltages. A precision voltage reference and comparator monitors the V CC input and compares it with a specified voltage threshold condition. When V CC falls below a specified trip point threshol ...
... The STM1061 low power voltage detector provides monitoring of battery, power-supply, and regulated system voltages. A precision voltage reference and comparator monitors the V CC input and compares it with a specified voltage threshold condition. When V CC falls below a specified trip point threshol ...
GG2310881094
... Recently, the utility service providers are putting function as a controlled voltage source. If we could use more and more restrictions on current total harmonic the neutral of three-phase series transformer to connect a distortion (THD) limits, drawn by nonlinear loads, to neutral wire to realize t ...
... Recently, the utility service providers are putting function as a controlled voltage source. If we could use more and more restrictions on current total harmonic the neutral of three-phase series transformer to connect a distortion (THD) limits, drawn by nonlinear loads, to neutral wire to realize t ...
Practical 1 RC Circuits Objectives
... battery. As the charge on the plates builds up, this back-voltage increases, opposing the action of the battery. As a consequence, the current flowing in the circuit decays, falling to zero when the back-voltage is exactly equal and opposite to the battery voltage. If we quickly remove the wires wi ...
... battery. As the charge on the plates builds up, this back-voltage increases, opposing the action of the battery. As a consequence, the current flowing in the circuit decays, falling to zero when the back-voltage is exactly equal and opposite to the battery voltage. If we quickly remove the wires wi ...
APEJ-2010-01
... systems. The simulation results and the experimental results are compared. The modified converter has reduced noise in the output. From the results, it is observed that the experimental results closely agree with the simulation results. ...
... systems. The simulation results and the experimental results are compared. The modified converter has reduced noise in the output. From the results, it is observed that the experimental results closely agree with the simulation results. ...
Instrumentation Measurement Device
... When a voltmeter is used to measure the voltage across a circuit component, the voltmeter circuit itself is in parallel with the circuit component. Since the parallel combination of two resistors is less than either resistor alone, the resistance seen by the source is less with the voltmeter connec ...
... When a voltmeter is used to measure the voltage across a circuit component, the voltmeter circuit itself is in parallel with the circuit component. Since the parallel combination of two resistors is less than either resistor alone, the resistance seen by the source is less with the voltmeter connec ...
Copyright 2002 American Institute of Physics. This
... 100 MHz 8-bit 4-channel digital storage oscilloscope via 50 Ω cryogenic coaxial lines. To retain the large-offset facility of the oscilloscope without significant loss in resolution, the amplifiers were designed to have a gain of ∼ 1/5. The 100 Ω resistor in series with the input eliminates high-fre ...
... 100 MHz 8-bit 4-channel digital storage oscilloscope via 50 Ω cryogenic coaxial lines. To retain the large-offset facility of the oscilloscope without significant loss in resolution, the amplifiers were designed to have a gain of ∼ 1/5. The 100 Ω resistor in series with the input eliminates high-fre ...
DAC8426 数据手册DataSheet 下载
... the design of the internal DAC switching to minimize transients on the reference voltage terminal (VREFOUT). Other devices connected to this reference terminal should have well behaved input loading characteristics. D/A converters such as the PMI PM7226A have been designed to minimize reference inpu ...
... the design of the internal DAC switching to minimize transients on the reference voltage terminal (VREFOUT). Other devices connected to this reference terminal should have well behaved input loading characteristics. D/A converters such as the PMI PM7226A have been designed to minimize reference inpu ...
1200V IGBT4 -High Power- Optimized Characteristics for High Current Modules M. Bäßler
... losses. However, during switching events the silicon volume not affected by carrier extraction through the electric field is determining the amount of carriers contributing to the tail current. This tail carrier/charge is crucial for the softness of an IGBT. In case of high transient over voltages t ...
... losses. However, during switching events the silicon volume not affected by carrier extraction through the electric field is determining the amount of carriers contributing to the tail current. This tail carrier/charge is crucial for the softness of an IGBT. In case of high transient over voltages t ...
KE2517881796
... related.The DVR( Dynamic voltage restorer) is a series connected device whose function is to protect a sensitive industrial load from voltage sags.The voltage sag compensator, based on a transformer-coupled is connected in series to voltage source inverter, is among the most costeffective solution a ...
... related.The DVR( Dynamic voltage restorer) is a series connected device whose function is to protect a sensitive industrial load from voltage sags.The voltage sag compensator, based on a transformer-coupled is connected in series to voltage source inverter, is among the most costeffective solution a ...
Voltage regulator
A voltage regulator is designed to automatically maintain a constant voltage level. A voltage regulator may be a simple ""feed-forward"" design or may include negative feedback control loops. It may use an electromechanical mechanism, or electronic components. Depending on the design, it may be used to regulate one or more AC or DC voltages.Electronic voltage regulators are found in devices such as computer power supplies where they stabilize the DC voltages used by the processor and other elements. In automobile alternators and central power station generator plants, voltage regulators control the output of the plant. In an electric power distribution system, voltage regulators may be installed at a substation or along distribution lines so that all customers receive steady voltage independent of how much power is drawn from the line.