Microscope Power Point File
... Nobel Prize for Physics in 1986 for his invention. (The other half of the Nobel Prize was divided between Heinrich Rohrer and Gerd Binnig for the STM.) In this kind of microscope, electrons are speeded up in a vacuum until their wavelength is extremely short, only one hundred-thousandth that of wh ...
... Nobel Prize for Physics in 1986 for his invention. (The other half of the Nobel Prize was divided between Heinrich Rohrer and Gerd Binnig for the STM.) In this kind of microscope, electrons are speeded up in a vacuum until their wavelength is extremely short, only one hundred-thousandth that of wh ...
Lesson-2 Light Microscopy
... Conjugate foci: Object placed at one end of lens will form a clear image on a screen kept at other side of lens. Conjugate foci vary in position. If object is nearer the lens, the image will be formed further away, at a greater magnification and inverted. This “real” image is formed by objective len ...
... Conjugate foci: Object placed at one end of lens will form a clear image on a screen kept at other side of lens. Conjugate foci vary in position. If object is nearer the lens, the image will be formed further away, at a greater magnification and inverted. This “real” image is formed by objective len ...
Nineteen Ways to do 3-Dimensional Imaging
... Speckle interferometry is also known as electronic speckle pattern interferometry or as TV holography. It depends on the object being imaged to have a diffusely reflecting (i.e., rough) surface to create the speckle pattern. It also requires a reference surface which must also be diffusely reflectin ...
... Speckle interferometry is also known as electronic speckle pattern interferometry or as TV holography. It depends on the object being imaged to have a diffusely reflecting (i.e., rough) surface to create the speckle pattern. It also requires a reference surface which must also be diffusely reflectin ...
Viewing Microstructures of Materials using the Optical Microscope
... Low magnification objectives can be used with high magnification eyepieces; however, high magnification objectives should only be used with 10 and 12.5x objectives in order to minimize the empty magnification effect. The theoretical resolving power of an optical microscope resides in the 0.2 micron ...
... Low magnification objectives can be used with high magnification eyepieces; however, high magnification objectives should only be used with 10 and 12.5x objectives in order to minimize the empty magnification effect. The theoretical resolving power of an optical microscope resides in the 0.2 micron ...
Hmwk 2 - People Server at UNCW
... as possible. If your handwriting is a problem use a text editor. 1. a. Write down the lens equation. b. Under what condition is the focal length equal to z’ ( distance of image plane from optical origin)? 2. Define the following: a. Optical origin b. Center of projection c. Line of sight d. Image pl ...
... as possible. If your handwriting is a problem use a text editor. 1. a. Write down the lens equation. b. Under what condition is the focal length equal to z’ ( distance of image plane from optical origin)? 2. Define the following: a. Optical origin b. Center of projection c. Line of sight d. Image pl ...
Transmission Electron Microscopy -TEM
... them as optical lenses do to light. After confirming these principles he set out to design the electron microscope, which he knew would be much more powerful than an ordinary optical microscope since electron waves were shorter than ordinary light waves. Electrons would therefore allow for greater m ...
... them as optical lenses do to light. After confirming these principles he set out to design the electron microscope, which he knew would be much more powerful than an ordinary optical microscope since electron waves were shorter than ordinary light waves. Electrons would therefore allow for greater m ...
New imaging modes for lenslet-array tandem scanning microscopes
... Fig. 5. Glass-ionomer cement / dentine interface. Combined reflection/ fluorescence image with full spectrum illumination. No information would have been derived from the dentine if fluorescence imaging mode had been used in isolation. The objective used was 60×, 1.4 NA oil immersion lens. ...
... Fig. 5. Glass-ionomer cement / dentine interface. Combined reflection/ fluorescence image with full spectrum illumination. No information would have been derived from the dentine if fluorescence imaging mode had been used in isolation. The objective used was 60×, 1.4 NA oil immersion lens. ...
Principles of TEM image formation Principles of TEM image
... phase variations over the plane surface. T(x,y) = A0exp[iφ(x,y)], for simplicity : A0 = 1 Assuming that the object is thin and phase shift φ is small The approximation of the emerged wave might be described as ...
... phase variations over the plane surface. T(x,y) = A0exp[iφ(x,y)], for simplicity : A0 = 1 Assuming that the object is thin and phase shift φ is small The approximation of the emerged wave might be described as ...
Topic 1: Introduction
... Body tube transmits the image from the objective lens to the ocular lens Objective lens is the primary lens the magnifies the specimen Stage holds the microscope slide Condenser focuses light through the specimen Diaphragm controls the amount of light entering the condenser Illuminator i ...
... Body tube transmits the image from the objective lens to the ocular lens Objective lens is the primary lens the magnifies the specimen Stage holds the microscope slide Condenser focuses light through the specimen Diaphragm controls the amount of light entering the condenser Illuminator i ...
7.13 Experimental Microbial Genetics
... the part of a light wave that passes through a specimen will be refracted and consequently will be out of phase with the part of the wave that does not pass through the specimen. When the two parts of the light wave are recombined, the resultant light will be brighter if they are in phase and less b ...
... the part of a light wave that passes through a specimen will be refracted and consequently will be out of phase with the part of the wave that does not pass through the specimen. When the two parts of the light wave are recombined, the resultant light will be brighter if they are in phase and less b ...
Sample Problems for Final
... illuminates a screen 1 meter away. Two separate colors of light, of approximately equal intensity, are incident on the slit: yellow light of wavelength 480 nm and red light of wavelength 640 nm. The central (m=0) maxima for both colors occur on the screen straight ahead of the slits. How far away fr ...
... illuminates a screen 1 meter away. Two separate colors of light, of approximately equal intensity, are incident on the slit: yellow light of wavelength 480 nm and red light of wavelength 640 nm. The central (m=0) maxima for both colors occur on the screen straight ahead of the slits. How far away fr ...
Document
... lasers contain an amplifying medium, located in a cavity between two mirrors, that can increase the intensity of light beam passing through it. This increased intensity will give additional energy into the beam itself. ...
... lasers contain an amplifying medium, located in a cavity between two mirrors, that can increase the intensity of light beam passing through it. This increased intensity will give additional energy into the beam itself. ...
3D widefield light microscopy with better than 100 nm axial resolution
... dramatically improved resolution in the difficult axial direction (Gustafsson et al., 1995, 1996). Here we report the first biological images from this system and the experimental verification of the resolution gain. In the new mode we call ‘image interference microscopy’, I2M, a fluorescent sample ...
... dramatically improved resolution in the difficult axial direction (Gustafsson et al., 1995, 1996). Here we report the first biological images from this system and the experimental verification of the resolution gain. In the new mode we call ‘image interference microscopy’, I2M, a fluorescent sample ...
"Contrast Enhancement in Light Microscopy". In: Current Protocols in
... visualization can be considerably improved by using either simple polarized light illumination or polarization contrast, whereby a polarizer below the condenser (usually oriented “eastwest”) linearly polarizes incoming wavefronts. An analyzer behind the objective is oriented at 90o to the polarizer; ...
... visualization can be considerably improved by using either simple polarized light illumination or polarization contrast, whereby a polarizer below the condenser (usually oriented “eastwest”) linearly polarizes incoming wavefronts. An analyzer behind the objective is oriented at 90o to the polarizer; ...
Lecture 18
... microscope can be characterized by the modulation transfer function (MTF) • MTF is measurement of microscope's ability to transfer contrast from the specimen to the image plane at specific resolution. • Incorporates resolution and contrast into one specification ...
... microscope can be characterized by the modulation transfer function (MTF) • MTF is measurement of microscope's ability to transfer contrast from the specimen to the image plane at specific resolution. • Incorporates resolution and contrast into one specification ...
Light Microscopy [10 credits]
... Determinants of optical resolution & contrast in the bright-field microscope Optical contrast techniques The epifluorescence microscope Confocal microscopy: Confocality & confocal microscopy methods Confocal microscopy – Components 1 Confocal microscopy – Components 2 Image acquisition parameters Sa ...
... Determinants of optical resolution & contrast in the bright-field microscope Optical contrast techniques The epifluorescence microscope Confocal microscopy: Confocality & confocal microscopy methods Confocal microscopy – Components 1 Confocal microscopy – Components 2 Image acquisition parameters Sa ...
File
... Good quality lenses in a camera reflect very little light and appear dark or slightly purple. A thin coating of a fluoride salt such as magnesium fluoride on the surface of the lens allows the majority of the light falling on the lens to pass through. The refractive index, n, of the coating is chose ...
... Good quality lenses in a camera reflect very little light and appear dark or slightly purple. A thin coating of a fluoride salt such as magnesium fluoride on the surface of the lens allows the majority of the light falling on the lens to pass through. The refractive index, n, of the coating is chose ...
Optical Properties of Colloids
... The numerical aperture of an optical microscope is generally less than unity. With oil-immersion objectives numerical apertures up to about 1.5 are attainable. So that, for light of wavelength 600 nm, this would permit a resolution limit of about 200 nm (0.2 µm). But, since the human eye can r ...
... The numerical aperture of an optical microscope is generally less than unity. With oil-immersion objectives numerical apertures up to about 1.5 are attainable. So that, for light of wavelength 600 nm, this would permit a resolution limit of about 200 nm (0.2 µm). But, since the human eye can r ...
lecture1
... to eliminate some of the peripheral rays but results in decrease aperture angle and therefore resolution This is Cs programs for image processing 2.0 mm in 2100, constant Bizzola Electron Microscopy 1999 ...
... to eliminate some of the peripheral rays but results in decrease aperture angle and therefore resolution This is Cs programs for image processing 2.0 mm in 2100, constant Bizzola Electron Microscopy 1999 ...
Optical Microscopy Beyond the Diffraction Limit
... high power semiconductor lasers using NSOM. In this case, the advantage of NSOM is to provide a means for localized high-resolution sensing of the propagating fields. The laser diodes we tested are designed to emit a nearly diffraction limited single lobe at 980 nm wavelength to be used for optical ...
... high power semiconductor lasers using NSOM. In this case, the advantage of NSOM is to provide a means for localized high-resolution sensing of the propagating fields. The laser diodes we tested are designed to emit a nearly diffraction limited single lobe at 980 nm wavelength to be used for optical ...
Tomographic Interference Microscopy of Living Cells
... technique is suitable only for small samples. The size of sample must be smaller than the diameter of the beam waist near the focal plane of the objective. For large objects it is necessary to use the technique represented in Fig 1e. The original procedure of the collected data processing, patented ...
... technique is suitable only for small samples. The size of sample must be smaller than the diameter of the beam waist near the focal plane of the objective. For large objects it is necessary to use the technique represented in Fig 1e. The original procedure of the collected data processing, patented ...
Microscopy
Microscopy is the technical field of using microscopes to view objects and areas of objects that cannot be seen with the naked eye (objects that are not within the resolution range of the normal eye). There are three well-known branches of microscopy: optical, electron, and scanning probe microscopy.Optical and electron microscopy involve the diffraction, reflection, or refraction of electromagnetic radiation/electron beams interacting with the specimen, and the collection of the scattered radiation or another signal in order to create an image. This process may be carried out by wide-field irradiation of the sample (for example standard light microscopy and transmission electron microscopy) or by scanning of a fine beam over the sample (for example confocal laser scanning microscopy and scanning electron microscopy). Scanning probe microscopy involves the interaction of a scanning probe with the surface of the object of interest. The development of microscopy revolutionized biology and remains an essential technique in the life and physical sciences.