WHM1722AE
... required. For +5V line trace length being longer than 6 inches without a decoupling capacitor, a 0.33 uF de-coupling capacitor, C1, with minimum rating voltage of 10V is needed across the +5V pin to ground. The capacitor must be rated in the temperature range of -55 0C to 100 0C to ensure the entire ...
... required. For +5V line trace length being longer than 6 inches without a decoupling capacitor, a 0.33 uF de-coupling capacitor, C1, with minimum rating voltage of 10V is needed across the +5V pin to ground. The capacitor must be rated in the temperature range of -55 0C to 100 0C to ensure the entire ...
TA2020-020 STEREO 20W (4Ω) CLASS
... amplified audio signal. Since the amplifier must drive the inductive LC output filter and speaker loads, the amplifier outputs can be pulled above the supply voltage and below ground by the energy in the output inductance. To avoid subjecting the TA2020-020 to potentially damaging voltage stress, it ...
... amplified audio signal. Since the amplifier must drive the inductive LC output filter and speaker loads, the amplifier outputs can be pulled above the supply voltage and below ground by the energy in the output inductance. To avoid subjecting the TA2020-020 to potentially damaging voltage stress, it ...
Dual 160 MHz Rail-to-Rail Amplifier AD8042
... While the AD8042 is internally short-circuit protected, this may not be sufficient to guarantee that the maximum junction temperature (150°C) is not exceeded under all conditions. To ensure proper operation, it is necessary to observe the maximum power derating curves. ...
... While the AD8042 is internally short-circuit protected, this may not be sufficient to guarantee that the maximum junction temperature (150°C) is not exceeded under all conditions. To ensure proper operation, it is necessary to observe the maximum power derating curves. ...
INSTRUCTION MANUAL OPTICAL INTERFACE UNIT (CROSS
... can cause serious damage, which often may not be immediately apparent but the reliability of the circuit will have been reduced. The electronic circuits are completely safe from electrostatic discharge when housed in the case. Do not expose them to risk of damage by removing the PCB unnecessarily. T ...
... can cause serious damage, which often may not be immediately apparent but the reliability of the circuit will have been reduced. The electronic circuits are completely safe from electrostatic discharge when housed in the case. Do not expose them to risk of damage by removing the PCB unnecessarily. T ...
FSBB15CH60 Motion SPM 3 Series FSBB15CH60 Motion SPM® 3 Series
... 7. To prevent errors of the protection function, the wiring around RF and CSC should be as short as possible. 8. In the short-circuit protection circuit, please select the RFCSC time constant in the range 1.5 ~ 2 s. 9. Each capacitor should be mounted as close to the pins of the Motion SPM 3 produc ...
... 7. To prevent errors of the protection function, the wiring around RF and CSC should be as short as possible. 8. In the short-circuit protection circuit, please select the RFCSC time constant in the range 1.5 ~ 2 s. 9. Each capacitor should be mounted as close to the pins of the Motion SPM 3 produc ...
MAX1479 300MHz to 450MHz Low-Power, Crystal-Based +10dBm ASK/FSK Transmitter General Description
... (PLL) VHF/UHF transmitter is designed to transmit ASK, OOK, and FSK data in the 300MHz to 450MHz frequency range. The MAX1479 supports data rates up to 100kbps in ASK mode and 20kbps in FSK mode (both Manchester coded). The device provides an adjustable output power of more than +10dBm into a 50Ω lo ...
... (PLL) VHF/UHF transmitter is designed to transmit ASK, OOK, and FSK data in the 300MHz to 450MHz frequency range. The MAX1479 supports data rates up to 100kbps in ASK mode and 20kbps in FSK mode (both Manchester coded). The device provides an adjustable output power of more than +10dBm into a 50Ω lo ...
single phase wiring 115v and 230v with governor switch
... BLACK WIRE - 115V STATOR WHITE WIRE - 230V STATOR ...
... BLACK WIRE - 115V STATOR WHITE WIRE - 230V STATOR ...
Low-Power VLSI Circuit Design
... Vdd/T=K/C. Based on this, the voltage measured at node X in time T equals the average power consumption from time 0 to T. The power curve is shown in Fig. 3(b). Can you estimate the average power consumption from time T1 to time T2 in Fig. 3(b) without changing the experiment set-up? If yes, give th ...
... Vdd/T=K/C. Based on this, the voltage measured at node X in time T equals the average power consumption from time 0 to T. The power curve is shown in Fig. 3(b). Can you estimate the average power consumption from time T1 to time T2 in Fig. 3(b) without changing the experiment set-up? If yes, give th ...
Electricity generators
... the generator is connected. DC generators are usually operated at fairly low voltages to avoid the sparking between brushes and commutator that occurs at high voltage. The highest potential commonly developed by such generators is 1500 V. In some newer machines this reversal is accomplished using po ...
... the generator is connected. DC generators are usually operated at fairly low voltages to avoid the sparking between brushes and commutator that occurs at high voltage. The highest potential commonly developed by such generators is 1500 V. In some newer machines this reversal is accomplished using po ...
TPS63700 数据资料 dataSheet 下载
... ramps up slowly to its nominal value. Soft start is implemented to limit the input current during start-up to avoid high peak currents at the battery which could interfere with other systems connected to the same battery. Without soft start, uncontrolled input peak currents flow to charge up the out ...
... ramps up slowly to its nominal value. Soft start is implemented to limit the input current during start-up to avoid high peak currents at the battery which could interfere with other systems connected to the same battery. Without soft start, uncontrolled input peak currents flow to charge up the out ...
VA, VAR and Power Factor – Fact or Fiction
... However, few know its definition, or its limitations. K = sum(H2*Ah2)/sum(Ah2); where H = harmonic #, and Ah = amplitude at that harmonic. Looks pretty simple, but the end result is often very dependent on how many harmonics have been used for the sum. Any K Factor result must include the number of ...
... However, few know its definition, or its limitations. K = sum(H2*Ah2)/sum(Ah2); where H = harmonic #, and Ah = amplitude at that harmonic. Looks pretty simple, but the end result is often very dependent on how many harmonics have been used for the sum. Any K Factor result must include the number of ...
Infineon - Article - Surge current pulse generator
... The market for pulse power applications is at present mainly dominated by the defence technology. Besides, there are increasingly industrial applications. Strong endeavours exist to replace the mainly used switches like spark gap, Ignitrons and Thyratrons with semiconductor switches. Among others, t ...
... The market for pulse power applications is at present mainly dominated by the defence technology. Besides, there are increasingly industrial applications. Strong endeavours exist to replace the mainly used switches like spark gap, Ignitrons and Thyratrons with semiconductor switches. Among others, t ...
TR41.9-16-02-008-Transverse Balance test procedures for FAST
... example, if the equipment would normally be connected to AC-power ground, cold-water-pipe ground, or if it has a metallic or partially metallic exposed surface, then these points are connected to the test ground plane. Similarly, if the EUT provides connections to other equipment through which groun ...
... example, if the equipment would normally be connected to AC-power ground, cold-water-pipe ground, or if it has a metallic or partially metallic exposed surface, then these points are connected to the test ground plane. Similarly, if the EUT provides connections to other equipment through which groun ...
product specification
... 4.1 Temperature and humidity: Unless otherwise specified elsewhere, tests shall be conducted at ordinary temperature (20+20C) and ordinary humidity (65+5%RH). 4.2 Storage of test specimen batteries: Specimen batteries to be tested shall be kept at the ambient temperature of 250C or below and at the ...
... 4.1 Temperature and humidity: Unless otherwise specified elsewhere, tests shall be conducted at ordinary temperature (20+20C) and ordinary humidity (65+5%RH). 4.2 Storage of test specimen batteries: Specimen batteries to be tested shall be kept at the ambient temperature of 250C or below and at the ...
Overview - Ocean Networks Canada
... Its structure is simpler than that of the conventional shifter-type. Loads applied to the cable are reduced as inlet and outlet for the cable are proximal to each other. Electro-magnetic brake is commonly used in the industry; On this winch, however, a worm gear unit behaves as a brake. Oil Filled S ...
... Its structure is simpler than that of the conventional shifter-type. Loads applied to the cable are reduced as inlet and outlet for the cable are proximal to each other. Electro-magnetic brake is commonly used in the industry; On this winch, however, a worm gear unit behaves as a brake. Oil Filled S ...
DPLS350E Features Mechanical Data
... Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use o ...
... Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use o ...