Protronic 100 Versatile controller for various requirements
... The Protronic 100 process controller is the basic model of the Protronic series. It can be operated as a process-specific single unit or in conjunction with higher-level systems. ...
... The Protronic 100 process controller is the basic model of the Protronic series. It can be operated as a process-specific single unit or in conjunction with higher-level systems. ...
Applications of monolithic bridge drivers
... used to conduct heat to the PC board copper) and handles 1A per channel (1.5 peak) at voltages up to 36 V. The L293E, also rated at 1 A/36 V, is mounted in a 16 + 4 lead POWERDIP package. A 15-lead MULTIWATT plastic power package is used for the L298N which handles up to 2A per channel at voltages t ...
... used to conduct heat to the PC board copper) and handles 1A per channel (1.5 peak) at voltages up to 36 V. The L293E, also rated at 1 A/36 V, is mounted in a 16 + 4 lead POWERDIP package. A 15-lead MULTIWATT plastic power package is used for the L298N which handles up to 2A per channel at voltages t ...
Study of Inductive-Capacitive Series Circuits Using
... An important conclusion of this chapter is that the electrical circuits, regardless of configuration, can be studied with this modern method which involves the use of virtual medium. Three elementary circuits are presented here, but the study modality can be extended to other circuits configuration ...
... An important conclusion of this chapter is that the electrical circuits, regardless of configuration, can be studied with this modern method which involves the use of virtual medium. Three elementary circuits are presented here, but the study modality can be extended to other circuits configuration ...
Introduction to ORCAD/PSPICE Capture (versions 9.1
... the simulation is complete. This program is usually used for graphs in other types of simulations. If you have any errors with your simulation then you should see what the problem is in the bottom left hand corner of this program or you can look at the session log details of the project by minimisin ...
... the simulation is complete. This program is usually used for graphs in other types of simulations. If you have any errors with your simulation then you should see what the problem is in the bottom left hand corner of this program or you can look at the session log details of the project by minimisin ...
From two-dimensional to three
... In order to determine the two-dimensional electron density, nd , in the dot which is typically smaller than the density in the unbound 2DEG at the same back-gate voltage, we measure magneto-Coulomb oscillations [4] as a function of Vpg for a set of back-gate voltages. For quantum dots on PQWs all to ...
... In order to determine the two-dimensional electron density, nd , in the dot which is typically smaller than the density in the unbound 2DEG at the same back-gate voltage, we measure magneto-Coulomb oscillations [4] as a function of Vpg for a set of back-gate voltages. For quantum dots on PQWs all to ...
Exp 1-Intro to Basic Laboratory Equipment
... pointer. The digital meter broadly known as DMM (digital multimeter) used number or numerical display to represent the measured quantity. It has high degree of accuracy and can eliminate usual reading errors compared to the analog meters. Students should be adept at using both meters throughout thei ...
... pointer. The digital meter broadly known as DMM (digital multimeter) used number or numerical display to represent the measured quantity. It has high degree of accuracy and can eliminate usual reading errors compared to the analog meters. Students should be adept at using both meters throughout thei ...
MLVDS Standard
... This Standard specifies the electrical characteristics of low-voltage differential signaling interface circuits that may be employed when specified for the interchange of binary signals between equipment sharing a common data interchange circuit. The electrical characteristics of the circuit are spe ...
... This Standard specifies the electrical characteristics of low-voltage differential signaling interface circuits that may be employed when specified for the interchange of binary signals between equipment sharing a common data interchange circuit. The electrical characteristics of the circuit are spe ...
Manual 2720 - Kusam
... circuit, and current through a circuit. When you use the current input, your clamp meter becomes a low impedance circuit element. Even if you correctly insert your clamp meter in to the circuit, you can still damage your meter. Don’t try to measure current in excess of your meter’s capacity. Check t ...
... circuit, and current through a circuit. When you use the current input, your clamp meter becomes a low impedance circuit element. Even if you correctly insert your clamp meter in to the circuit, you can still damage your meter. Don’t try to measure current in excess of your meter’s capacity. Check t ...
trade : boilermaker
... Design and wire the following control and main circuit to which a three phase slip ring induction motor can be connected i.e. Hand and automatic controlled resistance starter or current limiting starters (take into consideration protection and safety equipment that must be used). Connect three phase ...
... Design and wire the following control and main circuit to which a three phase slip ring induction motor can be connected i.e. Hand and automatic controlled resistance starter or current limiting starters (take into consideration protection and safety equipment that must be used). Connect three phase ...
Electronic components
... 1.3.3 Advantages of ceramic over mica and paper capacitor :(1) Economical, (2) Very High working voltage rating, (3) Very small size but large capacitance, (4) It has very low power factor and value decreases with increase in frequency. 1.3.4 Electrolytic Capacitor- The entire sandwich with plates a ...
... 1.3.3 Advantages of ceramic over mica and paper capacitor :(1) Economical, (2) Very High working voltage rating, (3) Very small size but large capacitance, (4) It has very low power factor and value decreases with increase in frequency. 1.3.4 Electrolytic Capacitor- The entire sandwich with plates a ...
EFMN-1A/1D SERIES
... - Do not connect the meter to a 3 phase - 400VAC – network. - Place the meter only in dry surroundings. - Do not mount the meter in an explosive area or expose the meter to dust, mildew and insects. - Make sure the wires are suitable for the maximum current of this meter. - Make sure the AC wires ar ...
... - Do not connect the meter to a 3 phase - 400VAC – network. - Place the meter only in dry surroundings. - Do not mount the meter in an explosive area or expose the meter to dust, mildew and insects. - Make sure the wires are suitable for the maximum current of this meter. - Make sure the AC wires ar ...
LMV861 数据资料 dataSheet 下载
... output impedance creates a phase lag, which reduces the phase margin of the amplifier. If the phase margin is significantly reduced, the response will be under damped which causes peaking in the transfer and, when there is too much peaking, the op amp might start oscillating. The LMV861 and LMV862 c ...
... output impedance creates a phase lag, which reduces the phase margin of the amplifier. If the phase margin is significantly reduced, the response will be under damped which causes peaking in the transfer and, when there is too much peaking, the op amp might start oscillating. The LMV861 and LMV862 c ...
project report on
... Distribution transformers account for the majority of losses in an electric power network. Of these losses, core heating accounts for the substantial portion. They can be considered constant so long as a transformer is in service. By contrast, winding losses are only significant under higher load co ...
... Distribution transformers account for the majority of losses in an electric power network. Of these losses, core heating accounts for the substantial portion. They can be considered constant so long as a transformer is in service. By contrast, winding losses are only significant under higher load co ...
Bellofram T1500 IP Transducer Installation Instructions
... creates a back pressure in the nozzle by restricting air flow. This back pressure acts as a pilot pressure to an integral booster relay. Consequently, as the input signal increases (or decreases, for reverse acting), output pressure increases proportionally. Zero and span are calibrated by turning e ...
... creates a back pressure in the nozzle by restricting air flow. This back pressure acts as a pilot pressure to an integral booster relay. Consequently, as the input signal increases (or decreases, for reverse acting), output pressure increases proportionally. Zero and span are calibrated by turning e ...
Evaluates: MAX109 MAX109 Evaluation Kit General Description Features
... clock signal must be connected to the CLKP SMA connector, and the CLKN SMA must be terminated with a 50Ω resistor to GNDI or an SMA end terminator with built-in 50Ω resistance. In differential mode, connect the differential clock signal across the CLKP (true) and CLKN (complementary) SMA connectors. ...
... clock signal must be connected to the CLKP SMA connector, and the CLKN SMA must be terminated with a 50Ω resistor to GNDI or an SMA end terminator with built-in 50Ω resistance. In differential mode, connect the differential clock signal across the CLKP (true) and CLKN (complementary) SMA connectors. ...
Table of contents
... A series of interface kits is available for operation systems that provide UPS monitoring. Each interface kit includes the special interface cable required to convert status signals from the UPS into signals which individual operating system recognize. The interface cable at UPS side must be connect ...
... A series of interface kits is available for operation systems that provide UPS monitoring. Each interface kit includes the special interface cable required to convert status signals from the UPS into signals which individual operating system recognize. The interface cable at UPS side must be connect ...
Status Indication Reference Design With LED
... The TPS22918 is a 5.5-V, 2-A load switch in a 6-pin SOT-23 package. To reduce voltage drop for lowvoltage and high-current rails, the device implements a low-resistance N-channel MOSFET, which reduces the drop out voltage across the device. The device has a configurable slew rate that reduces or eli ...
... The TPS22918 is a 5.5-V, 2-A load switch in a 6-pin SOT-23 package. To reduce voltage drop for lowvoltage and high-current rails, the device implements a low-resistance N-channel MOSFET, which reduces the drop out voltage across the device. The device has a configurable slew rate that reduces or eli ...
Data Sheet 85001-0369 -- 202 Synchronized Strobe - D
... 202 Series strobes are designed for 16 to 33 Vdc operation and must be connected to signal circuits that output a constant (not pulsed) voltage. A diode is used to allow full signal circuit supervision and polarized connections are made to terminals that accept up to #12 AWG (2.5mm²) wire. The 203 S ...
... 202 Series strobes are designed for 16 to 33 Vdc operation and must be connected to signal circuits that output a constant (not pulsed) voltage. A diode is used to allow full signal circuit supervision and polarized connections are made to terminals that accept up to #12 AWG (2.5mm²) wire. The 203 S ...