LT3507
... The LT3507 contains three independent, constant frequency, current mode, switching regulators with internal power switches plus a low dropout linear regulator. The three regulators share common circuitry including input source, voltage reference and oscillator, but are otherwise independent. Operati ...
... The LT3507 contains three independent, constant frequency, current mode, switching regulators with internal power switches plus a low dropout linear regulator. The three regulators share common circuitry including input source, voltage reference and oscillator, but are otherwise independent. Operati ...
Unit.5 Power Quality Monitoring
... continuous measurement of voltage and current over an extended period. • The process of analysis and interpretation has been traditionally performed manually, but recent advances in signal processing and artificial intelligence fields have made it possible to design and implement intelligent systems ...
... continuous measurement of voltage and current over an extended period. • The process of analysis and interpretation has been traditionally performed manually, but recent advances in signal processing and artificial intelligence fields have made it possible to design and implement intelligent systems ...
LT6210/LT6211 - Single/Dual Programmable Supply Current, R-R Output, Current Feedback Amplifiers
... Maximum Rating condition for extended periods may affect device reliability and lifetime. Note 2: As long as output current and junction temperature are kept below the absolute maximum ratings, no damage to the part will occur. Depending on the supply voltage, a heat sink may be required. Note 3: Th ...
... Maximum Rating condition for extended periods may affect device reliability and lifetime. Note 2: As long as output current and junction temperature are kept below the absolute maximum ratings, no damage to the part will occur. Depending on the supply voltage, a heat sink may be required. Note 3: Th ...
Analog Integrated Circuits Fundamental Building Blocks
... how is VDS1 chosen ? → consider transistor operating regions as Vout decreases → becomes important later in amplifier design for maximizing signal swing M1 is maintained in saturation by the constant VGS of M2 → if the voltage budget permits, VDS1 is typically chosen (1.5-2)VDSat1 ...
... how is VDS1 chosen ? → consider transistor operating regions as Vout decreases → becomes important later in amplifier design for maximizing signal swing M1 is maintained in saturation by the constant VGS of M2 → if the voltage budget permits, VDS1 is typically chosen (1.5-2)VDSat1 ...
A Pocket-Size, Direct-Reading VHF SWR Meter
... Assemble the pick-up section diodes, capacitors and trimmer potentiometers on the foil side of the main board and bring the diode leads to the rectangular pads (see Figure 3). The REFLECTED voltage pad is connected directly to the LM3914; the other pad is the FORWARD voltage connection. Be sure to g ...
... Assemble the pick-up section diodes, capacitors and trimmer potentiometers on the foil side of the main board and bring the diode leads to the rectangular pads (see Figure 3). The REFLECTED voltage pad is connected directly to the LM3914; the other pad is the FORWARD voltage connection. Be sure to g ...
GS-Series Pinsetters - MC Bowling Services
... WARNING: This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the installation manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to ...
... WARNING: This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the installation manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to ...
ELECTRICAL SYSTEMS FOR OFFSHORE SAILING
... Voltmeters: Voltmeters are voltage measuring devices. Although they can be found in both analog and digital forms, since all the action in a boat electrical system takes place in the range of 11 to 15 volts, and variations of 0.1 volt may be significant, only digital meters should be used onboard. E ...
... Voltmeters: Voltmeters are voltage measuring devices. Although they can be found in both analog and digital forms, since all the action in a boat electrical system takes place in the range of 11 to 15 volts, and variations of 0.1 volt may be significant, only digital meters should be used onboard. E ...
Agtron ST Seed Sensor Datasheet Rev 04
... Optical Detection Elements…..………………………………………..4 Optical Sampling Frequency (1) ..……………………………………. 15 kHz Optical Detection Zone………………………………………………… 2mm Minimum Particle Detection Size .……………………………………. 1.5mm Minimum Optical Cross Section Coverage .………………………….40% Optical Calibration Steps (2).………………………… ...
... Optical Detection Elements…..………………………………………..4 Optical Sampling Frequency (1) ..……………………………………. 15 kHz Optical Detection Zone………………………………………………… 2mm Minimum Particle Detection Size .……………………………………. 1.5mm Minimum Optical Cross Section Coverage .………………………….40% Optical Calibration Steps (2).………………………… ...
AP5004 PWM CONTROL 2.5A STEP-DOWN CONVERTER Description
... excellent transient characteristics. The PWM control circuit is able to vary the duty ratio linearly from 0% up to 90%. An enable function, an over-current protect function, and a short circuit protect function are built inside, and when OCP or SCP happens, the operation frequency will be reduced fr ...
... excellent transient characteristics. The PWM control circuit is able to vary the duty ratio linearly from 0% up to 90%. An enable function, an over-current protect function, and a short circuit protect function are built inside, and when OCP or SCP happens, the operation frequency will be reduced fr ...
Three-Phase TTR® Transformer Turns Ratio Test Set
... voltage signal applied to the high voltage winding and the voltage signal extracted from the low voltage winding. The phase deviation together with ratio error can be used as a low cost method of verifying accuracy class of all types of PTs and CTs at “zero burden.” The phase deviation between the h ...
... voltage signal applied to the high voltage winding and the voltage signal extracted from the low voltage winding. The phase deviation together with ratio error can be used as a low cost method of verifying accuracy class of all types of PTs and CTs at “zero burden.” The phase deviation between the h ...
MB15F74UL
... • When storing and transporting the device, put it in a conductive case. • Before handling the device, confirm the (jigs and) tools to be used have been uncharged (grounded) as well as yourself. Use a conductive sheet on working bench. • Before fitting the device into or removing it from the socket, ...
... • When storing and transporting the device, put it in a conductive case. • Before handling the device, confirm the (jigs and) tools to be used have been uncharged (grounded) as well as yourself. Use a conductive sheet on working bench. • Before fitting the device into or removing it from the socket, ...
(PME) Plan Check Questionnaire
... Regular plan check jobs require detailed review and is usually done in the backroom office. These jobs typically take more than 1 hour to review, and usually complex in nature, and usually needs code and engineering research. They usually contain numerous equipment and installation specifications, c ...
... Regular plan check jobs require detailed review and is usually done in the backroom office. These jobs typically take more than 1 hour to review, and usually complex in nature, and usually needs code and engineering research. They usually contain numerous equipment and installation specifications, c ...
ICS251 - Integrated Device Technology
... express or implied, including, but not limited to, the suitability of IDT’s products for any particular purpose, an implied warranty of merchantability, or non-infringement of the intellectual property rights of others. This document is presented only as a guide and does not convey any license under ...
... express or implied, including, but not limited to, the suitability of IDT’s products for any particular purpose, an implied warranty of merchantability, or non-infringement of the intellectual property rights of others. This document is presented only as a guide and does not convey any license under ...
ADDC02808PB 28 V, 200 W Pulsed DC/DC Converter with Integral
... The converter uses current mode control and employs a high performance opto-isolator in its feedback path to maintain isolation between input and output. The control circuit is designed to give a nearly constant output current as the output voltage drops from VO nom to VSC during a short circuit con ...
... The converter uses current mode control and employs a high performance opto-isolator in its feedback path to maintain isolation between input and output. The control circuit is designed to give a nearly constant output current as the output voltage drops from VO nom to VSC during a short circuit con ...
MAX8576–MAX8579 3V to 28V Input, Low-Cost, Hysteretic Synchronous Step-Down Controllers General Description
... internal LDO regulator allowing the controllers to function from only one 3V to 28V input supply. The MAX8578/MAX8579 do not contain the internal LDO and require a separate supply to power the IC when the input supply is higher than 5.5V. The MAX8576– MAX8579 output voltages are adjustable from 0.6V ...
... internal LDO regulator allowing the controllers to function from only one 3V to 28V input supply. The MAX8578/MAX8579 do not contain the internal LDO and require a separate supply to power the IC when the input supply is higher than 5.5V. The MAX8576– MAX8579 output voltages are adjustable from 0.6V ...
UNIT – 4 Explain the construction of Single phase transformer with
... This test is conducted to determine iron loss (or core loss) and no load current, I0 which is helpful in finding R0 and X0. In this test, the rated voltage is applied to the primary (usually low-voltage winding) while the secondary is left open circuited. A wattmeter ‘W’ a voltmeter ‘V’ and an ammet ...
... This test is conducted to determine iron loss (or core loss) and no load current, I0 which is helpful in finding R0 and X0. In this test, the rated voltage is applied to the primary (usually low-voltage winding) while the secondary is left open circuited. A wattmeter ‘W’ a voltmeter ‘V’ and an ammet ...
Notes
... (b)Environmental stress: Caused by surrounding conditions such as High temperature, high humidity, mechanical shock, vibration, high and low pressure, corrosive chemicals, dust in the air. All these conditions cause the components to fail.e.g. If the component is subjected to continual cycles of ...
... (b)Environmental stress: Caused by surrounding conditions such as High temperature, high humidity, mechanical shock, vibration, high and low pressure, corrosive chemicals, dust in the air. All these conditions cause the components to fail.e.g. If the component is subjected to continual cycles of ...