• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
NCV890204 2.0 A, 2 MHz Automotive Buck Switching Regulator with Programmable Spread
NCV890204 2.0 A, 2 MHz Automotive Buck Switching Regulator with Programmable Spread

... regulator intended for Automotive, battery−connected applications that must operate with up to a 36 V input supply. The regulator is suitable for systems with low noise and small form factor requirements often encountered in automotive driver information systems. The NCV890204 is capable of converti ...
Data Sheet  Features General Description
Data Sheet Features General Description

... The AUR9716 is a high efficiency step-down DC-DC voltage converter. The chip operation is optimized by peak-current mode architecture with built-in synchronous power MOS switchers. It is automatically switching between the normal PWM mode and LDO mode to offer improved system power efficiency coveri ...
notes and worksheets for Electricity and Circuits.
notes and worksheets for Electricity and Circuits.

... other forms of energy. The charges "work" to get through the bulb, resistor or clock, so the electrical potential energy (PEE) is transformed into other forms of energy. Examples: ...
Herbert Stemmler
Herbert Stemmler

... The AC side transformer needs three separated secondary sides with the leakage inductances mainly concentrated at the secondary sides (Figure 7-16). This is to decouple the commutation loops of the three single-phase cycloconverters. Cycloconverters are able to deliver output currents ia,b,c with a ...
Sensors and Actuators
Sensors and Actuators

... The digital signal is the easiest for the computer to understand because it reads the signal as either "on" or "off." The analog signal must be conditioned or converted to digital so the computer can understand it. (This will be covered later.) While a vehicle may have many different sensors, there ...
Temperature Measurement Devices
Temperature Measurement Devices

... calculated. This means that the IE efficiencies for a particular motor may be declared lower than it was under EFF efficiency rating scheme. All motors have a rated load, but most are designed so that they run over a range of loads. Typically, the load will be 50% to 110% rated load and generally, m ...
Individual capacitor voltage balancing in H
Individual capacitor voltage balancing in H

... STATCOM) in literature. Sorting algorithm needs current sign information to provide a correct sorting pattern. As a consequence, when the exchanging current that flows in the cells is zero the sorting algorithm is unable to take the correct insertion decision for proper balancing of the capacitor vo ...
Instructions For Rotation Check of Large Motors
Instructions For Rotation Check of Large Motors

... For the remaining 2 scenarios (Motor is T3/T2/T1 and power system is A/B/C…. OR motor is T1/T2/T3 and power system is C/B/A), then motor leads should be relabeled or an alternate connection should be selected (for example T1-B, T2-A, T3-C). However, neutral leads are not always available, so a metho ...
MC3479 Stepper Motor Driver
MC3479 Stepper Motor Driver

80 Series V Industrial True-RMS Multimeter with Temperature
80 Series V Industrial True-RMS Multimeter with Temperature

Generator protection and control REG630 Flexibility for
Generator protection and control REG630 Flexibility for

Stepper Motor Driver MC3479
Stepper Motor Driver MC3479

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... Unlike a brushed DC motor, the commutation of a BLDC motor is controlled electronically. To rotate the BLDC motor, the stator windings should be energized in a sequence. Rotor position is sensed by Hall Effect sensors embedded into the stator which gives the sequence of phase energization. Most of B ...
Aalborg Universitet Applied to Parallel UPS Systems
Aalborg Universitet Applied to Parallel UPS Systems

... Droop Control, despite its capability of load sharing between UPSs without control communication, presents a major drawback that must be overcomed, that is its compromise between proper power sharing accuracy and good amplitude and frequency output voltage regulation [2]. Among the techniques to sol ...
EE 416/JEE316
EE 416/JEE316

... maximum and the other of 100 A maximum. We shall take for granted the probe's behavior at large currents and study its behavior at small currents. Use the Load Box (see diagram at end of handout) to connect the DC wall outlet (allegedly set to 25 V) in series with a digital readout DC current measur ...
Design and Implementation of Energy Stored Quasi ZSI System for
Design and Implementation of Energy Stored Quasi ZSI System for

P84646
P84646

... When calculating the total currents: Use Table 2 to determine the highest value of “RMS Current” for an individual strobe (across the expected operating voltage range of the strobe), then multiply these values by the total number of strobes; be sure to add the currents for any other appliances, incl ...
Turn-on behavior of power LTT and light driver modules
Turn-on behavior of power LTT and light driver modules

... High voltage LTTs are most perspective power switches for high power commutation in megawatt range. These power semiconductors are now available with current up to 3500A and voltage up to 8000V. They are controlled with infrared light pulses of some tens mW, have excellent turn-on characteristics, l ...
Table 2
Table 2

... 18. The Insulation levels for Distribution, Class 1 and Class 2 transformers shall be selected from this table for both the highvoltage and low-voltage windings. 19. All test levels are line to ground. 20. The applied test levels are not applicable to wye-connected windings unless they have been spe ...
Dual Negative Regulated Charge Pump
Dual Negative Regulated Charge Pump

... The simulation and measurement results of the negative charge pump are tabulated in Table 1. From Table 1, the output voltage of the output 1 and 2 is -1.596V and -1.583V, respectively when negative charge is turned ON. The output voltage of output 1 and 2 is 0.007 when they are turned OFF, thereby ...
Switch Mode DC Power Supplies SEC-1212 SEC-1223
Switch Mode DC Power Supplies SEC-1212 SEC-1223

2.88 2.88 2.88 H I LO A 0.00 S L P 8 . 8 . 8 . 8 .
2.88 2.88 2.88 H I LO A 0.00 S L P 8 . 8 . 8 . 8 .

... 1) Physical: The meter should be located in a visible position with easy access for operation of the pushbuttons. The display has adjustable brightness for various lighting conditions, but for best visibility do not place the meter in full daylight. The location should also be dry and protected. The ...
RL Line/Load Reactors
RL Line/Load Reactors

... HARMONIC COMPENSATION makes MTE reactors suitable for use on either the drive input or drive output. They are designed to carry full rated fundamental current and will also handle current and frequencies associated with harmonics up to 50% over the fundamental. This robust design allows all MTE reac ...
BP5039A
BP5039A

... No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products" ...
UC2874-2 数据资料 dataSheet 下载
UC2874-2 数据资料 dataSheet 下载

... voltage down to a tightly regulated output voltage. Special design techniques allow this bipolar IC to deliver exceptional performance while consuming approximately 6mA of supply current over an input voltage range of 4.5 to 35 volts. Fixed frequency operation allows synchronization to an existing s ...
< 1 ... 1018 1019 1020 1021 1022 1023 1024 1025 1026 ... 1640 >

Voltage optimisation

Voltage optimisation is a term given to the systematic controlled reduction in the voltages received by an energy consumer to reduce energy use, power demand and reactive power demand. While some voltage 'optimisation' devices have a fixed voltage adjustment, others electronically regulate the voltage automatically.Voltage optimisation systems are typically installed in series with the mains electrical supply to a building, allowing all its electrical equipment to benefit from an optimised supply.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report