Coaxial Cable Protection
... For Quarter wave coaxial stubs, from 2GHz down, the inductance of the stub will still allow considerable voltage to be presented to the equipment input (+ 9Vpk, - 4Vpk ringing for the entire test pulse waveform) measured for a 900MHz 1/4 wave stub with a 3kA 8/20s test waveform and the stub output ...
... For Quarter wave coaxial stubs, from 2GHz down, the inductance of the stub will still allow considerable voltage to be presented to the equipment input (+ 9Vpk, - 4Vpk ringing for the entire test pulse waveform) measured for a 900MHz 1/4 wave stub with a 3kA 8/20s test waveform and the stub output ...
STEVAL-IEM003V1
... designed to drive a low voltage/high current 3phase brushless synchronous or asynchronous motor up to 3 kW. Typical uses for the system include battery-powered traction system applications or high-power tools. The demonstration board is composed of two stacked boards. The top layer is a power board ...
... designed to drive a low voltage/high current 3phase brushless synchronous or asynchronous motor up to 3 kW. Typical uses for the system include battery-powered traction system applications or high-power tools. The demonstration board is composed of two stacked boards. The top layer is a power board ...
3A1978
... directly into the cable of the system/equipment to be protected using the connectors at both ends. The overvoltage protection circuit has a valve characteristic, i.e., the BSPD5BNCSI is installed so that the output indicated on the equipment label ( protected) faces towards the equipment to be prot ...
... directly into the cable of the system/equipment to be protected using the connectors at both ends. The overvoltage protection circuit has a valve characteristic, i.e., the BSPD5BNCSI is installed so that the output indicated on the equipment label ( protected) faces towards the equipment to be prot ...
STEVAL-PSQ001V1
... The industrial standard bus is 24 V, but this voltage fluctuates and the maximum required input voltage level can be up to 36 V. Additional surge protection is also mandatory for power supply input in industrial applications. The purpose of this evaluation board is to address all of required paramet ...
... The industrial standard bus is 24 V, but this voltage fluctuates and the maximum required input voltage level can be up to 36 V. Additional surge protection is also mandatory for power supply input in industrial applications. The purpose of this evaluation board is to address all of required paramet ...
2 3 4 5 6 7 8 9 10 11 1 1 2 3 4 5 6 7 TECH SPECS
... counter clockwise to fully clockwise. This enables very low frequency changes to be perceived and additionally causes erratic changes to settle on the maximum and minimum values. The default setting for this control is in the fully CCW position. Adjust only as needed or desired. ...
... counter clockwise to fully clockwise. This enables very low frequency changes to be perceived and additionally causes erratic changes to settle on the maximum and minimum values. The default setting for this control is in the fully CCW position. Adjust only as needed or desired. ...
Yunting Yin
... widely used in industry production to be a voltage reference, it still has some characteristics to be explored and some methods to be found to improve its performance, especially for the voltage variation across the certain temperature range. In this paper, the second order coefficient of the voltag ...
... widely used in industry production to be a voltage reference, it still has some characteristics to be explored and some methods to be found to improve its performance, especially for the voltage variation across the certain temperature range. In this paper, the second order coefficient of the voltag ...
Key Ignition Concepts to Know
... Capacitance is measured in Farads, named after Michael Faraday. In most circuits, a farad is much too large to be practical, so we typically use microfarads, which are 1/1,000,000th of a farad. Power and Energy Power and energy are sometimes used interchangeably, but they are two different things. P ...
... Capacitance is measured in Farads, named after Michael Faraday. In most circuits, a farad is much too large to be practical, so we typically use microfarads, which are 1/1,000,000th of a farad. Power and Energy Power and energy are sometimes used interchangeably, but they are two different things. P ...
Presentation by Marioan Piekutowski ( pptx , 59 kB ) - SC B4
... SCR < 2 indicate potential problems with commutation failures, harmonics, phase unbalance, instability (v and/or f) ...
... SCR < 2 indicate potential problems with commutation failures, harmonics, phase unbalance, instability (v and/or f) ...
Krell Audio Components MRA
... has high output impedance and delivers current, not voltage, to the amplifier. The amplifierÂ’s input senses and amplifies this current, which is not altered by interconnect cableÂ’s impedance characteristics because the cable imped- ance and reactive effects are reduced to at least a million times ...
... has high output impedance and delivers current, not voltage, to the amplifier. The amplifierÂ’s input senses and amplifies this current, which is not altered by interconnect cableÂ’s impedance characteristics because the cable imped- ance and reactive effects are reduced to at least a million times ...
Battery, Light Bulbs, and Wires
... 6) Compare the brightness of the bulbs in your series and parallel circuits containing three bulbs: _______________________________________________________________________________ 7) What happens when you make a circuit with no resistance? Why do you think this happens? ...
... 6) Compare the brightness of the bulbs in your series and parallel circuits containing three bulbs: _______________________________________________________________________________ 7) What happens when you make a circuit with no resistance? Why do you think this happens? ...
Metadyne
A metadyne is a direct current electrical machine with two pairs of brushes. It can be used as an amplifier or rotary transformer. It is similar to a third brush dynamo but has additional regulator or ""variator"" windings. It is also similar to an amplidyne except that the latter has a compensating winding which fully counteracts the effect of the flux produced by the load current. The technical description is ""a cross-field direct current machine designed to utilize armature reaction"". A metadyne can convert a constant-voltage input into a constant-current, variable-voltage output.