• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Real Time Voltage and Current Phase Shift Analyzer for Power
Real Time Voltage and Current Phase Shift Analyzer for Power

... reactive power in power lines which can be optimized (reduced). Reactive power is the main component which overloads power lines and brings excessive thermal stress to conductors. If the reactive power is optimized, it can significantly lower the electricity consumption (from 10 to 30%—varies betwee ...
Experiment # 1 -- Diodes and Diode Circuits
Experiment # 1 -- Diodes and Diode Circuits

... sensitive. For the MultiSim symbols, the upper terminal is the + terminal. In general, there are polarity markings on a “real-world” device. In most cases, these devices are rated at 9 VDC, but actually operate over a wider voltage range, typically from 3-18 VDC. When using the devices in MultiSim, ...
On-site Measurement of Load and No-load Losses of
On-site Measurement of Load and No-load Losses of

... In addition to the above mentioned ones, the contributions of uncertainty of measurements in the case of load loss measurement also include: standard deviation, power multimeter resolution, the effect of the measured current on raising the temperature of transformer windings and the consequent incre ...
Line Loss Minimization in Isolated Substations
Line Loss Minimization in Isolated Substations

... and phase angle to follow reference values. The reference load phase angle was calculated from the line loss minimum condition, whereas the reference voltage magnitude was calculated based on the voltage magnitude of each load in the loop system. Line loss minimization can be achieved if the loop cu ...
AM42-0007 GaAs MMIC VSAT Power Amplifier, 2.0 W 14.0 - 14.5 GHz
AM42-0007 GaAs MMIC VSAT Power Amplifier, 2.0 W 14.0 - 14.5 GHz

... The AM42-0007 is a three-stage MMIC linear power amplifier in a lead-free, ceramic bolt down style hermetic package. The AM42-0007 employs a fully matched chip with internally decoupled gate and drain bias networks and an output power detector. The AM42-0007 is designed to be operated from a constan ...
lec10-elec
lec10-elec

... The input impedance of a CB stage is much smaller than that of a CE stage. ...
Document
Document

Aalborg Universitet
Aalborg Universitet

... systems. These typically consist of installing either passive or active filters to selectively compensate harmonic frequencies. However, by adding proper control strategies to the inverters connected to the microgrid, these can be used to improve the power quality of the microgrid [5]. The authors i ...
Circuit Protection from Transient Voltage by Varistor
Circuit Protection from Transient Voltage by Varistor

... across the signal lines. However, this capacitor cannot suppress voltage surges. Therefore, when circuit protection from voltage surges is required, a varistor is used as a voltage protection device. When a voltage surge exceeding a specified voltage (varistor voltage) is applied, the varistor suppr ...
Contributions to Low-Cost, Non-Resonant Electronic Ballasts
Contributions to Low-Cost, Non-Resonant Electronic Ballasts

lec13
lec13

Hijacking Power and Bandwidth from the Mobile Phone’s Audio Interface {samkuo,thschmid,prabal
Hijacking Power and Bandwidth from the Mobile Phone’s Audio Interface {samkuo,thschmid,prabal

IOSR Journal of Dental and Medical Sciences (IOSR-JDMS)
IOSR Journal of Dental and Medical Sciences (IOSR-JDMS)

... quality of power is the one, which experience any voltage, current or frequency deviation, from normal operation. For ideal electrical systems, the supplied power should have perfect current and voltage sinusoidal waveforms, being safe and reliable. The electric utilities can control the voltage lev ...
International Electrical Engineering Journal (IEEJ) Vol. 5 (2014) No.12, pp. 1673-1679
International Electrical Engineering Journal (IEEJ) Vol. 5 (2014) No.12, pp. 1673-1679

Phono Stage - Classic Valve Design
Phono Stage - Classic Valve Design

... pilot lamp, if you do not convert to a LED power indicator. If you convert to an LED one (order CK-57), the recommended auxiliary transformer is 12.6V @ 300mA (Hammond 166F12 or 166F12C/D is fine). The 166F12 transformer can be mounted across the hole left by the can capacitor if you use our PAS Reg ...
MDO600-16N1 Datasheet
MDO600-16N1 Datasheet

... ● Isolation Voltage: 3600 V~ ● Industry standard outline ● RoHS compliant ● Base plate: Copper internally DCB isolated ● Advanced power cycling ...
ECE 310 - University of Illinois at Urbana–Champaign
ECE 310 - University of Illinois at Urbana–Champaign

TN1208 - MachXO2 Hardware Checklist
TN1208 - MachXO2 Hardware Checklist

Inverter Power Stage Connected with PV-Grid
Inverter Power Stage Connected with PV-Grid

... using bidirectional devices [8]. Hierarchical control for DC and AC microgrids proposed [9]. A reconfiguration strategy proposed for PV systems to achieve maximum power generation from non-uniformly aged PV module [10]. Grid with PV inverters, owing to the growth of world’s power demand, the necessi ...
File
File

DAC
DAC

Flash Memory - School of Electrical Engineering and Computer
Flash Memory - School of Electrical Engineering and Computer

... In this context, we considered heuristic approaches for power management and therefore the solution is near optimum Explore efficient optimization tools to find exact optimal solution Online arrival of tasks can be incorporated Consider multi voltage levels. (This project we have considered two volt ...
1.2kV Class Energy Efficient Autotransformer
1.2kV Class Energy Efficient Autotransformer

5. Power supplies requirements
5. Power supplies requirements

... The voltage rise times and fall times for the high voltage pulse must be fast enough to obtain maximum width state while attaining the 1.0 µs flat top. In any case, the pulse width at 75 % must not be more than 3.5 µs. The voltage must be tuneable between 50 and 100 % of the maximum voltage. ...
Comdyna Model GP-6 Analog Computer, Serial Number 794
Comdyna Model GP-6 Analog Computer, Serial Number 794

... and 5 (but with the circuits modified to eliminate damping feedback by removal of the 2ζωn/G3 feedback connection shown on Figure 1, so that each circuit was nominally an undamped oscillator). The SJ receptacle of a multiplier network must be connected to the SJ receptacle of a summing amplifier (Op ...
< 1 ... 495 496 497 498 499 500 501 502 503 ... 838 >

Metadyne



A metadyne is a direct current electrical machine with two pairs of brushes. It can be used as an amplifier or rotary transformer. It is similar to a third brush dynamo but has additional regulator or ""variator"" windings. It is also similar to an amplidyne except that the latter has a compensating winding which fully counteracts the effect of the flux produced by the load current. The technical description is ""a cross-field direct current machine designed to utilize armature reaction"". A metadyne can convert a constant-voltage input into a constant-current, variable-voltage output.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report