Arduino Section I
... One of the most useful tools in an engineer or Maker’s toolkit. The three most important thing to remember: ...
... One of the most useful tools in an engineer or Maker’s toolkit. The three most important thing to remember: ...
Multifrequency bio-impedance measurement: undersampling
... response Vz as the sum of carrier signals. After amplification in a programmable gain amplifier PGA the voltage response will be digitized by the aid of a sampleand-hold circuit S/H and an ADC. Then the signals will be demodulated digitally using a synchronous (phase sensitive quadrature) detection ...
... response Vz as the sum of carrier signals. After amplification in a programmable gain amplifier PGA the voltage response will be digitized by the aid of a sampleand-hold circuit S/H and an ADC. Then the signals will be demodulated digitally using a synchronous (phase sensitive quadrature) detection ...
Pulse_meter_project_brl4
... – Build a noninverting amplifier with a gain of 11. A high pass filter at 1 radian/sec and low pass at 100 radians/sec. Use power supply voltages of +5 and -5 volts. – Test it by connecting the input to the waveform generator and the output to the scope as shown below. – Set up the waveform generato ...
... – Build a noninverting amplifier with a gain of 11. A high pass filter at 1 radian/sec and low pass at 100 radians/sec. Use power supply voltages of +5 and -5 volts. – Test it by connecting the input to the waveform generator and the output to the scope as shown below. – Set up the waveform generato ...
Physics 517/617 Experiment 1 Instrumentation and Resistor Circuits
... 1) Study the operation of the oscilloscope, multimeter, power supplies, and wave generator. For the oscilloscope you should try to understand the function of all the knobs or buttons on the front panel. Some buttons may have several functions and some of the functions will not be relevant for this c ...
... 1) Study the operation of the oscilloscope, multimeter, power supplies, and wave generator. For the oscilloscope you should try to understand the function of all the knobs or buttons on the front panel. Some buttons may have several functions and some of the functions will not be relevant for this c ...
1 (Vahid 4.1) Given a timer ... frequency of 10 MHz: (a)Determine ...
... frequency of 10 MHz: (a)Determine its range and resolution. (b) Calculate the terminal count value needed to measure 3 ms intervals. (c) If a prescaler is added, what is the minimum division needed to measure an interval of 100 ms? (Divisions should be in powers of 2). Determine this design’s range ...
... frequency of 10 MHz: (a)Determine its range and resolution. (b) Calculate the terminal count value needed to measure 3 ms intervals. (c) If a prescaler is added, what is the minimum division needed to measure an interval of 100 ms? (Divisions should be in powers of 2). Determine this design’s range ...
Capacitors
... The same time constant RC describes the rate of charging as well as the rate of discharging. After a time of one time constant t = RC, the voltage is V = Vo (1 – e(-RC/RC)) = Vo (1 – e(-1)) = 0.63 Vo That is, the voltage across the capacitor in 0.63 (or 63 %) of its maximum value. When a square wave ...
... The same time constant RC describes the rate of charging as well as the rate of discharging. After a time of one time constant t = RC, the voltage is V = Vo (1 – e(-RC/RC)) = Vo (1 – e(-1)) = 0.63 Vo That is, the voltage across the capacitor in 0.63 (or 63 %) of its maximum value. When a square wave ...
Circuit Note CN-0060
... video decoder are all automotive qualified which makes both products ideal for auto-vision applications. Low power, low cost, high speed, and fast settling make these amplifiers well suited for many video applications where these requirements are very important. Figure 1 shows only a single amplifie ...
... video decoder are all automotive qualified which makes both products ideal for auto-vision applications. Low power, low cost, high speed, and fast settling make these amplifiers well suited for many video applications where these requirements are very important. Figure 1 shows only a single amplifie ...
TAD-Datenblatt_RT043_12BH7A-STR_310113
... 12BH7A-STR TAD Premium Selected High Performance Medium-Mu Twin Triode The all-new TAD 12BH7A-STR combines the best sonic and mechanic performance of the NOS RCA black plate with the GE version. A maximum of reliability with outrageous tonal quality makes the new TAD 12BH7A-STR the first choice for ...
... 12BH7A-STR TAD Premium Selected High Performance Medium-Mu Twin Triode The all-new TAD 12BH7A-STR combines the best sonic and mechanic performance of the NOS RCA black plate with the GE version. A maximum of reliability with outrageous tonal quality makes the new TAD 12BH7A-STR the first choice for ...
Data Transmission and Encoding
... Nonreturn to Zero Inverted Nonreturn to zero inverted on ones Constant voltage pulse for duration of bit Data encoded as presence or absence of signal transition at beginning of bit time Transition (low to high or high to low) denotes a binary 1 No transition denotes binary 0 An example of di ...
... Nonreturn to Zero Inverted Nonreturn to zero inverted on ones Constant voltage pulse for duration of bit Data encoded as presence or absence of signal transition at beginning of bit time Transition (low to high or high to low) denotes a binary 1 No transition denotes binary 0 An example of di ...
Oscilloscopes and their Calibration
... square wave signal for vertical gain calibration. Most modern models using solid-state displays, e.g., liquid crystal displays (LCDs), are typically calibrated using a DC stimulus, with some models utilizing the consecutive application of a zero-centered, ±DC signal for gain calibration, where othe ...
... square wave signal for vertical gain calibration. Most modern models using solid-state displays, e.g., liquid crystal displays (LCDs), are typically calibrated using a DC stimulus, with some models utilizing the consecutive application of a zero-centered, ±DC signal for gain calibration, where othe ...
ECE 3235 Electronics II
... somewhat triangular). Note that in this part, the amplitude of the input must be varied to keep the peak-to-peak value of the output constant at 10 V. 7) Record the value of the frequency where distortion starts. (note: Displaying Vin and Vout simultaneously on the same axis should help you detect a ...
... somewhat triangular). Note that in this part, the amplitude of the input must be varied to keep the peak-to-peak value of the output constant at 10 V. 7) Record the value of the frequency where distortion starts. (note: Displaying Vin and Vout simultaneously on the same axis should help you detect a ...
Getting started on the HP3577 network analyzer
... The HP 3577 network analyzer can make Bode plot and other frequency-domain measurements. The source output produces a sinusoid of controllable amplitude and frequency, used to sinusoidally excite a circuit. The receiver input channels R, A, and possibly B, are used to measure the resulting sinusoids ...
... The HP 3577 network analyzer can make Bode plot and other frequency-domain measurements. The source output produces a sinusoid of controllable amplitude and frequency, used to sinusoidally excite a circuit. The receiver input channels R, A, and possibly B, are used to measure the resulting sinusoids ...
Capacitors and RC circuits
... Please place name(s) here. Open up the oscilloscope (right click) so that the display shows. Activate the simulation and flip the switch so that the capacitor is charging. Then when the capacitor is almost fully charged flip the switch so that it discharges. Let it (almost) fully discharge and stop ...
... Please place name(s) here. Open up the oscilloscope (right click) so that the display shows. Activate the simulation and flip the switch so that the capacitor is charging. Then when the capacitor is almost fully charged flip the switch so that it discharges. Let it (almost) fully discharge and stop ...
Oscilloscope types
This is a subdivision of the Oscilloscope article, discussing the various types and models of oscilloscopes in greater detail.