UBA Ultrasonic Fork Sensors - WayCon Positionsmesstechnik
... In addition, the output signal can also be inverted via teach-in, i.e. either rising or falling signal with increasing coverage of the sensor. • Status A (material is fully introduced): push key A for min. 2 s until yellow LED near A blinks 3x (acknowledgment by lighting of all 3 LEDs) • Status B (n ...
... In addition, the output signal can also be inverted via teach-in, i.e. either rising or falling signal with increasing coverage of the sensor. • Status A (material is fully introduced): push key A for min. 2 s until yellow LED near A blinks 3x (acknowledgment by lighting of all 3 LEDs) • Status B (n ...
Diagnostic Testing for Oxygen Sensors
... 1. Ignition off, disconnect sensor connector 2. Attach multimeter to sensor signal connector (+ black cable) and earth connector (-battery) 3. Reconnect sensor 4. Run engine continuously for 2 mins at 2000 rpm 5. Carry out test with engine warm ...
... 1. Ignition off, disconnect sensor connector 2. Attach multimeter to sensor signal connector (+ black cable) and earth connector (-battery) 3. Reconnect sensor 4. Run engine continuously for 2 mins at 2000 rpm 5. Carry out test with engine warm ...
wvme-dm_install
... one pin on the VME bus backplane carries +12 volts. This provides insufficient current capacity to meet the startup current requirements for many disk drives. The P2 paddle board has a power connector which supplies additional power through the user defined pins. Four additional pins are used for +1 ...
... one pin on the VME bus backplane carries +12 volts. This provides insufficient current capacity to meet the startup current requirements for many disk drives. The P2 paddle board has a power connector which supplies additional power through the user defined pins. Four additional pins are used for +1 ...
Technical Data: BUC Power Supplies
... DuraComm™ RMSL-1248C 600 W IDU BUC Power Supply The DuraComm™ RMSL-1248C is a 300 W/600 W heavy-duty indoor switch mode power supply (SMPS). It is rack-mounted and suitable for IF-powered BUCs up to 300 W and externally powered BUCs up to 600 W. The Bias-T blocks incoming DC and multiplexes 48 V DC ...
... DuraComm™ RMSL-1248C 600 W IDU BUC Power Supply The DuraComm™ RMSL-1248C is a 300 W/600 W heavy-duty indoor switch mode power supply (SMPS). It is rack-mounted and suitable for IF-powered BUCs up to 300 W and externally powered BUCs up to 600 W. The Bias-T blocks incoming DC and multiplexes 48 V DC ...
Building a BASIC Stamp I Flight Computer (Powerpoint)
... Repeat, making a white, red, and black cable connector as well. These fit together both ways so the shrink wrap will indicate polarity. ...
... Repeat, making a white, red, and black cable connector as well. These fit together both ways so the shrink wrap will indicate polarity. ...
THE POWERPAL USER MANUAL Instructions
... contains numerous safety features that guard against damaging low-voltage electronics. It is also designed to provide long lasting power and includes anti-shock features. It has wide compatibility with USB and DC ports. For home users, the PowerPal makes an excellent substitute or backup power suppl ...
... contains numerous safety features that guard against damaging low-voltage electronics. It is also designed to provide long lasting power and includes anti-shock features. It has wide compatibility with USB and DC ports. For home users, the PowerPal makes an excellent substitute or backup power suppl ...
i-class Induction Heating
... 25-pin. Sub-D-connector with main analog and digital signals And a 9-pin.-Sub-D-Interface to load up new Firmware. Optional an additional Interface (also after installation) can be installed. These interface-cards are available as Profibus, Interbus-S, DeviceNet, RS 232/485 and others. ...
... 25-pin. Sub-D-connector with main analog and digital signals And a 9-pin.-Sub-D-Interface to load up new Firmware. Optional an additional Interface (also after installation) can be installed. These interface-cards are available as Profibus, Interbus-S, DeviceNet, RS 232/485 and others. ...
Hardwire Kit Installation Instructions - TSS
... uses a 5 volt or 12 volt power source. This is important, as you need to use the three pin plug for the power adapter for 12 volt units and the two pin plug for 5 volt units. The plugs are not interchangeable, which makes it difficult to use the wrong power harness and plug. After determining the co ...
... uses a 5 volt or 12 volt power source. This is important, as you need to use the three pin plug for the power adapter for 12 volt units and the two pin plug for 5 volt units. The plugs are not interchangeable, which makes it difficult to use the wrong power harness and plug. After determining the co ...
Guide to preventing shocks from entertai nment systems
... protected. The csa of the cable is dependent on the length of run to the connection to the main earthing system for the premises and therefore may require a conductor of a larger csa than stated. The connection must only be removable with a tool and should be made in such a way that It remains intac ...
... protected. The csa of the cable is dependent on the length of run to the connection to the main earthing system for the premises and therefore may require a conductor of a larger csa than stated. The connection must only be removable with a tool and should be made in such a way that It remains intac ...
We`re more than just cables and cord sets. Terminology Term and
... National Electrical Manufacturers Association, an organization based in the U.S. that sets many common standards used in electrical products. OD Outer Diameter, the outer diameter of a cord. OEM Original Equipment Manufacturer. Pigtail A very short patch cable or wiring adapter. Primarily used in th ...
... National Electrical Manufacturers Association, an organization based in the U.S. that sets many common standards used in electrical products. OD Outer Diameter, the outer diameter of a cord. OEM Original Equipment Manufacturer. Pigtail A very short patch cable or wiring adapter. Primarily used in th ...
(K153) TIP Signal Circuit Open Or High Resistance GC0071236 C
... NOTE: The voltage should be approximately 0.0 volts (plus or minus.1 volt) with the jumper wire in place. ...
... NOTE: The voltage should be approximately 0.0 volts (plus or minus.1 volt) with the jumper wire in place. ...
SMT Ultra-Miniature Coaxial Connectors
... 1) To disconnect connectors, hook the end portion of E.FL-LP-N and U.FL-LP-N-2 onto the connector cover and pull off vertically in the direction of the connector coupling axis. 1) To remove the connector directly, hold the connector cover and pull off U.FL-LP-N-2 vertically in the direction of the c ...
... 1) To disconnect connectors, hook the end portion of E.FL-LP-N and U.FL-LP-N-2 onto the connector cover and pull off vertically in the direction of the connector coupling axis. 1) To remove the connector directly, hold the connector cover and pull off U.FL-LP-N-2 vertically in the direction of the c ...
Your doors and windows are your home`s weakest
... Your doors and windows are your home's weakest points—and to a burglar, an unsecured door or window is like a big "WELCOME" sign. That's why contact sensors are some of the most popular home security devices. Your Forest Security System will be designed to include a contact on every entry/exit door ...
... Your doors and windows are your home's weakest points—and to a burglar, an unsecured door or window is like a big "WELCOME" sign. That's why contact sensors are some of the most popular home security devices. Your Forest Security System will be designed to include a contact on every entry/exit door ...
Cabling - Pacific Audio Visual Institute
... 2 conductor connector positive and negative Fit into binding terminals on amplifiers Tab is usually wired to the negative terminal Can be piggy backed, connected to each other Recently outlawed in Europe ...
... 2 conductor connector positive and negative Fit into binding terminals on amplifiers Tab is usually wired to the negative terminal Can be piggy backed, connected to each other Recently outlawed in Europe ...
6. Run the low voltage cable which will supply
... bedding sand under the border course of pavers to keep it from being damaged when digging in the yard and so it can be easily located. Form a loop in the cable where the lights will be located (with a rubber band if desired) to leave enough slack for connection of the light to the power cable. 7. Wh ...
... bedding sand under the border course of pavers to keep it from being damaged when digging in the yard and so it can be easily located. Form a loop in the cable where the lights will be located (with a rubber band if desired) to leave enough slack for connection of the light to the power cable. 7. Wh ...
TIA-4000 Optical/Electrical Converter
... damaged condition, apparent or concealed, it must be noted on the freight bill or express receipt and signed by the carrier’s agent. Failure to do so could result in the carrier refusing to honor the claim. Upon filing a claim TTI should be notified. ...
... damaged condition, apparent or concealed, it must be noted on the freight bill or express receipt and signed by the carrier’s agent. Failure to do so could result in the carrier refusing to honor the claim. Upon filing a claim TTI should be notified. ...
AUAV3 basic connections
... PORT2_TxD – optoisolated PORT2 transmit data ( UART2 TxD ) / OUTPUT / PORT2_RxD – optoisolated PORT2 received data ( UART2 TxD ) / INPUT / PORT2_Vss – optoisolated PORT2 ...
... PORT2_TxD – optoisolated PORT2 transmit data ( UART2 TxD ) / OUTPUT / PORT2_RxD – optoisolated PORT2 received data ( UART2 TxD ) / INPUT / PORT2_Vss – optoisolated PORT2 ...
What is a schematic?
... Meter or Motor (not used) Plug. For power connectors, the male half of a connector set as defined by the shell. For RF connectors, the male half of a connector set as defined by the center pin. Transistor, including field effect, thyristors, triac, and SCR Resistor, including variable resistor Switc ...
... Meter or Motor (not used) Plug. For power connectors, the male half of a connector set as defined by the shell. For RF connectors, the male half of a connector set as defined by the center pin. Transistor, including field effect, thyristors, triac, and SCR Resistor, including variable resistor Switc ...
AUAV3 basic connections
... GPSRx – INPUT – receives data from the GPS GPSTx – OUTPUT – transmits data to the GPS +5V is a 5V power for the GPS with up to 250mA load capabilities GND PLEASE NOTE, THE GPS TxD AND RxD ARE 3.3V COMPATTIBLE. Page | 4 ...
... GPSRx – INPUT – receives data from the GPS GPSTx – OUTPUT – transmits data to the GPS +5V is a 5V power for the GPS with up to 250mA load capabilities GND PLEASE NOTE, THE GPS TxD AND RxD ARE 3.3V COMPATTIBLE. Page | 4 ...
Model STA-3108D1 Packing List
... Exercise extreme caution when a shock hazard is present. Lethal voltage may be present on cable connector jacks or test fixtures. The American National Standards Institute (ANSI) states that a shock hazard exists when voltage levels greater than 30V RMS, 42.4V peak, or 60VDC are present. A good safe ...
... Exercise extreme caution when a shock hazard is present. Lethal voltage may be present on cable connector jacks or test fixtures. The American National Standards Institute (ANSI) states that a shock hazard exists when voltage levels greater than 30V RMS, 42.4V peak, or 60VDC are present. A good safe ...
OPTICAL SYSTEM DEVICES FREQUENTLY ASKED QUESTIONS
... When I hook up GP2Y0A02YK0F I see a lot of noise on the line, how do I get rid of this? SHARP recommends using RC filters on Vcc and Vo as called out below. The R and C values are recommended starting points you can adjust as needed for your application. ...
... When I hook up GP2Y0A02YK0F I see a lot of noise on the line, how do I get rid of this? SHARP recommends using RC filters on Vcc and Vo as called out below. The R and C values are recommended starting points you can adjust as needed for your application. ...
Shuttle XPC Accessory PC45G
... 3. Now start re-connecting the components to the power supply unit. Never force a connector into a socket, as this may result in damage of the power supply unit and possible other hardware components which is not covered by the warranty. 4. Notice: This power supply has a 24-pin connector for the ma ...
... 3. Now start re-connecting the components to the power supply unit. Never force a connector into a socket, as this may result in damage of the power supply unit and possible other hardware components which is not covered by the warranty. 4. Notice: This power supply has a 24-pin connector for the ma ...
Shuttle XPC Accessory PC45G (250W Power Supply)
... 3. Now start re-connecting the components to the power supply unit. Never force a connector into a socket, as this may result in damage of the power supply unit and possible other hardware components which is not covered by the warranty. 4. Notice: This power supply has a 24-pin connector for the ma ...
... 3. Now start re-connecting the components to the power supply unit. Never force a connector into a socket, as this may result in damage of the power supply unit and possible other hardware components which is not covered by the warranty. 4. Notice: This power supply has a 24-pin connector for the ma ...
Visual Call Indicator
... The ASG Products SL-10 Visual Call Indicator is a strobe light triggered by 1) An intercom "call" signal, or 2) a contact closure. The strobe light flashes at a rate of about two flashes per second and can provide a silent , but highly visible alert signal to personnel. This visual alert signal is e ...
... The ASG Products SL-10 Visual Call Indicator is a strobe light triggered by 1) An intercom "call" signal, or 2) a contact closure. The strobe light flashes at a rate of about two flashes per second and can provide a silent , but highly visible alert signal to personnel. This visual alert signal is e ...
Gender of connectors and fasteners
In electrical and mechanical trades and manufacturing, each half of a pair of mating connectors or fasteners is conventionally assigned the designation male or female. The ""female"" connector is generally a receptacle that receives and holds the ""male"" connector.The assignment is a direct analogy with genitalia and sexual intercourse; the part bearing one or more protrusions, or which fits inside the other, being designated male in contrast to the part containing the corresponding indentations, or fitting outside the other, being designated female. Extension of the analogy results in the verb to mate being used to describe the process of connecting two corresponding parts together.In some cases (notably electrical power connectors), the gender of connectors is selected according to rigid rules, to enforce a sense of one-way directionality (e.g. a flow of power from one device to another). This gender distinction is implemented to enhance safety or ensure proper functionality by preventing unsafe or non-functional configurations from being set up.In terms of mathematical graph theory, an electrical power distribution network made up of plugs and sockets is a directed tree, with the directionality arrows corresponding to the female-to-male transfer of electrical power through each mated connection. This is an example where male and female connectors have been deliberately designed and assigned to physically enforce a safe network topology.In other contexts, such as plumbing, one-way flow is not enforced through connector gender assignment. Flows through piping networks can be bidirectional, as in underground water distribution networks which have designed-in redundancy. In plumbing situations where one-way flow is desired, it is implemented through other means (e.g. gravity flow, one-way check valves), and not through male-female gender schemes.