• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
BSN-10 is an 8–channel rf generator working at pulse width
BSN-10 is an 8–channel rf generator working at pulse width

... BSN-10 is an 8–channel rf generator working at pulse width modulated (PWM). It supports ultrasound transducer at frequency from 1MHz to 10MHz with an output power up to 120watts. Each channel has its own programmable high voltage generator and delay control and so it provides a perfect solution for ...
Laboratory 8 Lock-in amplifier1 Prior to the lab, • Understand the
Laboratory 8 Lock-in amplifier1 Prior to the lab, • Understand the

... function generator as the noise signal. This allows you to assess more easily the effect of the signal frequency and amplitude of the noise on the output of the lock-in-amplifier. The signal is a square wave with a voltage minimum at 0 V. Such a signal would be obtained after chopping of a real cont ...
Project: sun tracker
Project: sun tracker

... current flowing through RA and RB. The threshold and trigger inputs monitor the capacitor voltage and when it reaches 2/3Vcc (threshold), the output becomes low and the discharge pin is connected to 0V. The capacitor discharges with current flowing through RB into the discharge pin. When the voltage ...
Lab 1: Common-source Amplifiers Introduction Preparation
Lab 1: Common-source Amplifiers Introduction Preparation

Op Amp Amplifier
Op Amp Amplifier

AAR Analog Input to Two High and Low Trip Level Relay Outputs
AAR Analog Input to Two High and Low Trip Level Relay Outputs

... Check the wiring configuration of any other loads that may be connected to this transformer. If required by BAS or controller specification, the 24 VAC neutral can be earth grounded at the transformer. Analog input, digital input, and analog output circuits should not be earth grounded at two points ...
No Slide Title
No Slide Title

RLC Series Circuits ( )
RLC Series Circuits ( )

... Connect the AC power source, inductor, capacitor, and resistor in series as shown in Figure 3. Initially, use component values C = 10-7 farad , L = 10-2 Henry, and R = 600 Ohms. Set the signal generator at sinusoidal output, and use the oscilloscope to measure the instantaneous voltage VR across R , ...
Lab 2 Applications of the 555 Timer
Lab 2 Applications of the 555 Timer

... from when the LED initially illuminated, turned off, then turned back on and produced an average period of 24.7 ± 0.3sec which is around a 20% error in comparison to the predicted values. The Ton and TOff of the LED was then recorded in order to calculate the duty cycle of the circuit. Using the sam ...
Capacitor Self
Capacitor Self

Experiment - University of Guelph Physics
Experiment - University of Guelph Physics

... The regulator circuit is as shown below: it uses a Zener diode as a voltage reference (VZ = 5.5V), and a single transistor connected as a voltage follower (or Emitter Follower). Double check to be sure you have not accidentally interchanged any of the transistor leads, also the connections on the Ze ...
Epiphone_Valve_Junio..
Epiphone_Valve_Junio..

Experiment 1-6
Experiment 1-6

... In many experiments, one needs to either monitor a signal over a long period of time or measure a quantity, such as voltage and current, which may vary with time very fast. In these cases, one may use a computer to control the experiment and take data. Many experimental instruments are now equipped ...
Visual CW Tuning Indicator
Visual CW Tuning Indicator

... Connect the audio input to the speaker, line out, phone patch out, or similar connector on your receiver/transceiver. With its high input impedance, this tuning indicator does not noticeably load down even line-level audio outputs. Tune in a constant carrier or calibrator signal of the desired pitch ...
the Enclosed DC Drives product datasheet.
the Enclosed DC Drives product datasheet.

... CHANNEL 5. Linear ramp with variable ramp rate and ramp reset input. All channels are short circuit protected and can drive upto 10, 10K pots with + or signals. Also included is a precision power supply with +/-12v and +/-24v outputs, the unit can be powered from 110/240v AC supplies. ...
Lecture 10
Lecture 10

... Many of the devices and sensors interfaced to a MCU produce varying voltage levels (analog signals) rather than binary vectors (digital signals). For this reason most modern MCU's include built-in analog-to-digital (A/D) conversion circuits. These circuits accept a voltage level on an input line and ...
Multifrequency bio-impedance measurement: undersampling
Multifrequency bio-impedance measurement: undersampling

... measurement could be a typical DSP-based system, with classical analog front-end containing an analog-to-digital converter (ADC), including sample-and-hold circuit (S/H), a digital-to-analog converter (DAC), with a lowpass filter (LPF), and programmable gain amplifies (PGA) at the analog input of th ...
display
display

... 2. Apply the sine wave signal to the electrodes of one channel. Ensure that the right leg driver is connected to ground and the unused channel inputs are also grounded. 3. Using an oscilloscope verify that the gain is approximately 0dB as measured at the output. See figure below for expected frequen ...
continuous-time signal
continuous-time signal

... response to the sum of the inputs is the sum of the individual outputs. – A system is homogeneous if the output for input ax(t) , where a is a scalar, is a y(t). – A system is linear if it is additive and homogenous. – That is, if x1(t) y1(t), and x2(t)  y2(t), and a1 and a2 are scalars, then a sy ...
RLC Circuit SP222
RLC Circuit SP222

... Adjust either the capacitance or the time scale so that you can see several (~8) cycles of the damped oscillation. Save the data in a file and construct a plot or your screen. ...
File - Solayman EWU
File - Solayman EWU

... Maximum power transform theorem can be used to determine the Thevenin’s equivalent resistance of a circuit. According to the maximum power transform theorem,maximum power will be transformed to load resistance when the load resistance is equal to the thevenin’s equivalent resistance between the two ...
Circuit Analysis of Overdrive Tube Amplifier Circuits
Circuit Analysis of Overdrive Tube Amplifier Circuits

... This paper covers a simple and relatively non-technical analysis of the overdrive tube amplifier circuits. The specific model I analyzed was the BYOC Overdrive II circuit, which itself was a clone of the famous Ibanez TS (Tube Screamer) 808. The circuit is meant to emulate the sound effects of tube ...
LA7625 - Audio Lab of Ga
LA7625 - Audio Lab of Ga

... The LA7625 is based on the LA7620 with the video circuit DC restoration factor changed to 100%. The LA7625 is small, multifunction ICs in which video, chroma and deflection circuits for NTSC color TV system are packaged in a shrink-type DIP30S (the same type as the earlier DIP22). In addition to bei ...
spring 2016 - Ecs.csus.edu
spring 2016 - Ecs.csus.edu

... block. The first is the pulse amplitude, and the pulse period T sec. You can assume a rectangular pulse with 50 % duty cycle (i.e. half period on, and half period off). Since this pulse train samples the source signal, its frequency should be many times higher than that of the source signal. The zer ...
Input offset voltage
Input offset voltage

... Application of a trigger causes a change to the quasistable state.An external trigger signal generated due to charging and discharging of the capacitor produces the transition to the original stable state ...
< 1 ... 372 373 374 375 376 377 378 379 380 ... 395 >

Oscilloscope history



This article discusses the history and development of oscilloscope technology.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report