Designing an Optical Theremin
... function that will tune the frequency to one of the musical pitches. The conditioned signal will be transformed into a sine wave that is generated with controlled frequency and amplitude based on our input signals. We will use the MyDaq to sample the sine wave and output an audio signal. ...
... function that will tune the frequency to one of the musical pitches. The conditioned signal will be transformed into a sine wave that is generated with controlled frequency and amplitude based on our input signals. We will use the MyDaq to sample the sine wave and output an audio signal. ...
Probes-Fact
... Probes provide a physical and electrical connection between the oscilloscope and the test point on your device. With an ideal probe, the signal at the oscilloscope input would exactly match the signal at the test point. Performance terms and considerations for choosing a probe include: Attenuation ...
... Probes provide a physical and electrical connection between the oscilloscope and the test point on your device. With an ideal probe, the signal at the oscilloscope input would exactly match the signal at the test point. Performance terms and considerations for choosing a probe include: Attenuation ...
HY-DIV168N-3 - Pennybuying Offical Blog | The Offical Blog Of
... Figure 1 is a wiring schematic of the drive 1, the definition of control signals PUL +: step pulse signal is input side or the positive pulse signal input positive terminal PUL-: the negative input of the negative input pulse signal or a positive pulse signal DIR +: stepping direction signal input t ...
... Figure 1 is a wiring schematic of the drive 1, the definition of control signals PUL +: step pulse signal is input side or the positive pulse signal input positive terminal PUL-: the negative input of the negative input pulse signal or a positive pulse signal DIR +: stepping direction signal input t ...
Exp04rev
... 3. Construct the RC circuit illustrated in Figure 1. Use the BNC to “micrograbber” cables to make component connections,(remember to check that the amplification factor for CH1 and CH2 are 1x). When using the probes, use common sense precautions to avoid damaging the sensitive contacts and clips. Fi ...
... 3. Construct the RC circuit illustrated in Figure 1. Use the BNC to “micrograbber” cables to make component connections,(remember to check that the amplification factor for CH1 and CH2 are 1x). When using the probes, use common sense precautions to avoid damaging the sensitive contacts and clips. Fi ...
What shall we do with an unused op-amp?
... supply rails. With a dual-supply system, ground is ideal, but connecting to the positive or negative supply of a single supply system will cause saturation and the resulting power waste if the offset voltage has the wrong polarity. The “potential somewhere between the supply rails” may be any point ...
... supply rails. With a dual-supply system, ground is ideal, but connecting to the positive or negative supply of a single supply system will cause saturation and the resulting power waste if the offset voltage has the wrong polarity. The “potential somewhere between the supply rails” may be any point ...
Laboratory Exercise 12 – Process Control Applications
... The point here is that we can get analog voltages out of the computer pretty easily. And that allows us to exercise control over circuitry in the external world that takes a range of analog voltage values. The Variable Trigger/ Adjustable LED One use that we make of the D/A in my research lab is to ...
... The point here is that we can get analog voltages out of the computer pretty easily. And that allows us to exercise control over circuitry in the external world that takes a range of analog voltage values. The Variable Trigger/ Adjustable LED One use that we make of the D/A in my research lab is to ...
Abstract
... The HART protocol permits the process variable to continue to be transmitted by the 420mA analog signal and additional information pertaining to other variable, parameters, device configuration, calibration, and device diagnostics to be transmitted digitally at the same time. Thus, a wealth of addit ...
... The HART protocol permits the process variable to continue to be transmitted by the 420mA analog signal and additional information pertaining to other variable, parameters, device configuration, calibration, and device diagnostics to be transmitted digitally at the same time. Thus, a wealth of addit ...
OctoberBest Quick Analog Design Presentation
... Step 6: Add an External Signal Generator Add a signal Generator by clicking on the sine wave on the tool bar and then place the signal generator ...
... Step 6: Add an External Signal Generator Add a signal Generator by clicking on the sine wave on the tool bar and then place the signal generator ...
TU5PFP030
... to provide 10 kW continuous-wave (CW) to the resonance cavity in CYCHU-10, some designs and experiments about the RF amplifier have been accomplished. A method of picking up a special aliased signal of DDS output as the target RF signal is adopted in our study. The chip AD9850 is used to synthesize ...
... to provide 10 kW continuous-wave (CW) to the resonance cavity in CYCHU-10, some designs and experiments about the RF amplifier have been accomplished. A method of picking up a special aliased signal of DDS output as the target RF signal is adopted in our study. The chip AD9850 is used to synthesize ...
Programmable Drum Machine Hardware Review
... piezo pulse duration must be extended to last at least as long as the sampling period. To achieve an appropriate pulse duration specification, a parallel RC circuit is used to set a slow voltage decay at the rectified sensor output. ...
... piezo pulse duration must be extended to last at least as long as the sampling period. To achieve an appropriate pulse duration specification, a parallel RC circuit is used to set a slow voltage decay at the rectified sensor output. ...
Heath SB-610 Monitor Scope Modifications
... Remove all three wires to the lugs of the old vertical gain control (AJ in the 5B-6IO man ual ) a nd remove the old control a nd knobs keepin g the wires in order so the y may be soldered to the n ew con trol. Before mou nti ng the new pot, b e sure th at th e knob shaft will extend just far e nough ...
... Remove all three wires to the lugs of the old vertical gain control (AJ in the 5B-6IO man ual ) a nd remove the old control a nd knobs keepin g the wires in order so the y may be soldered to the n ew con trol. Before mou nti ng the new pot, b e sure th at th e knob shaft will extend just far e nough ...
SOiid-State oua1-c1ock Generator
... tronics can use and easily afford. Snap on a capacitor and out comes a stable, buffered, 3-volt high symmetrical square wave of any frequency you want from once every ten seconds up to 30 MHz. If you want, you can knob tune the frequency over a 3.5 to 1 range with a single capacitor, or voltage cont ...
... tronics can use and easily afford. Snap on a capacitor and out comes a stable, buffered, 3-volt high symmetrical square wave of any frequency you want from once every ten seconds up to 30 MHz. If you want, you can knob tune the frequency over a 3.5 to 1 range with a single capacitor, or voltage cont ...
Built in test-mode in tachometer of Fords with LCD Instrument panels
... new instrument cluster. EE Displays the hexadecimal value for EE level (used when requesting assistance from hotline). If alternating flashes of FAIL and EE level are displayed replace instrument cluster. dt Displays hexadecimal coding of final manufacturing test date (used when requesting assistanc ...
... new instrument cluster. EE Displays the hexadecimal value for EE level (used when requesting assistance from hotline). If alternating flashes of FAIL and EE level are displayed replace instrument cluster. dt Displays hexadecimal coding of final manufacturing test date (used when requesting assistanc ...
Figure Q5 - University of Brighton
... The input voltage Vs to the circuit shown in Figure Q5 is a step of 350 V dc voltage having a series resistor R =5 to limit the maximum current through the capacitor to 500 A. Determine the values of snubber inductance if the maximum permitted vales of diT/dt and dVT/dt are 350A/s and 350 V/s. I ...
... The input voltage Vs to the circuit shown in Figure Q5 is a step of 350 V dc voltage having a series resistor R =5 to limit the maximum current through the capacitor to 500 A. Determine the values of snubber inductance if the maximum permitted vales of diT/dt and dVT/dt are 350A/s and 350 V/s. I ...
Homework Ch 4 - ECM
... 4. When a potentiometer is connected between the null inputs of an op amp, the input voltage can be partially eliminated by adjusting the potentiometer. a. True b. False ...
... 4. When a potentiometer is connected between the null inputs of an op amp, the input voltage can be partially eliminated by adjusting the potentiometer. a. True b. False ...
Coding digital signals Boolean algebra, Boolean functions
... • We have seen that the electrical property of capacitance has been the main physical principle behind many of the sensors that we have discussed. • This has made it a useful tool in measuring small vibrations. Capacitance can also be used to measure much greater distances than we have seen so far. ...
... • We have seen that the electrical property of capacitance has been the main physical principle behind many of the sensors that we have discussed. • This has made it a useful tool in measuring small vibrations. Capacitance can also be used to measure much greater distances than we have seen so far. ...
Oscilloscope history
This article discusses the history and development of oscilloscope technology.