Uninterruptible Power Supply - Mitsubishi Electric Power Products, Inc.
... Transistors (IGBT) in both the converter and inverter. This unique combination simply means our 9800A UPS offers superior reliability and ...
... Transistors (IGBT) in both the converter and inverter. This unique combination simply means our 9800A UPS offers superior reliability and ...
LT3091 - –36V, 1.5A Negative Linear Regulator with Programmable
... differential needed to maintain regulation at a specified output current. In dropout, the output voltage is: VIN + VDROPOUT. Note 8. GND pin current is tested with VIN = VOUT(NOMINAL) and a current source load. Therefore, the device is tested while operating in dropout. This is the worst-case GND pi ...
... differential needed to maintain regulation at a specified output current. In dropout, the output voltage is: VIN + VDROPOUT. Note 8. GND pin current is tested with VIN = VOUT(NOMINAL) and a current source load. Therefore, the device is tested while operating in dropout. This is the worst-case GND pi ...
Design Principles of Superconducting Magnets
... conduction equation inside the coil. This is a quite complicated computational task. However, the critical current of HTS magnet can be estimated by monitoring the average electric field, Eave, between the coil terminals: Eave = V/l, where V is the voltage between the coil terminals, and l is the le ...
... conduction equation inside the coil. This is a quite complicated computational task. However, the critical current of HTS magnet can be estimated by monitoring the average electric field, Eave, between the coil terminals: Eave = V/l, where V is the voltage between the coil terminals, and l is the le ...
P83160
... 3. Select largest backbox shown in Mounting Options where possible, to provide additional wiring room for easy installation. 4. Conduit entrance to backboxes should be selected to insure sufficient wiring clearance for installed equipment. When extension rings are required, conduit should enter thro ...
... 3. Select largest backbox shown in Mounting Options where possible, to provide additional wiring room for easy installation. 4. Conduit entrance to backboxes should be selected to insure sufficient wiring clearance for installed equipment. When extension rings are required, conduit should enter thro ...
Product Summary Features and Benefits COMPLEMENTARY PAIR ENHANCEMENT MODE MOSFET
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
SP3249E 数据资料DataSheet下载
... arc. The discharge current rise time is constant since the energy is directly transferred without the air-gap arc. In situations such as hand held systems, the ESD charge can be directly discharged to the equipment from a person already holding the equipment. The current is transferred on to the key ...
... arc. The discharge current rise time is constant since the energy is directly transferred without the air-gap arc. In situations such as hand held systems, the ESD charge can be directly discharged to the equipment from a person already holding the equipment. The current is transferred on to the key ...
Comanche Peak Nuclear Power Plant, Units 3 & 4 COL Application
... plant switching station is connected to the transmission grid by four outgoing transmission lines. The one line diagram of the offsite power system is shown in Figure 8.2-202. The plant switching station has two independent control houses (#1 and #2) that contain the control and protection equipment ...
... plant switching station is connected to the transmission grid by four outgoing transmission lines. The one line diagram of the offsite power system is shown in Figure 8.2-202. The plant switching station has two independent control houses (#1 and #2) that contain the control and protection equipment ...
MAX13448E ±80V Fault-Protected Full-Duplex RS-485 Transceiver General Description
... Lead Temperature (soldering, 10s) .................................+300°C ...
... Lead Temperature (soldering, 10s) .................................+300°C ...
Synchronous speed
... minimum when the poles are aligned with the (rotating) magnetic field of the stator, and increases with the angle between them. This creates a torque pulling the rotor into alignment with the nearest pole of the stator field. Thus at synchronous speed the rotor is "locked" to the rotating stator fie ...
... minimum when the poles are aligned with the (rotating) magnetic field of the stator, and increases with the angle between them. This creates a torque pulling the rotor into alignment with the nearest pole of the stator field. Thus at synchronous speed the rotor is "locked" to the rotating stator fie ...
SN74SSTV32867 数据资料 dataSheet 下载
... Package thermal impedance, θJA (see Note 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40°C/W Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C † Stresses ...
... Package thermal impedance, θJA (see Note 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40°C/W Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C † Stresses ...
Click here
... FIGURE 20-5 A cutaway of a General Motors CS-130D generator showing the rotor and cooling fans that are used to force air through the unit to remove the heat created when it is charging the battery and supplying electrical power for the vehicle. ...
... FIGURE 20-5 A cutaway of a General Motors CS-130D generator showing the rotor and cooling fans that are used to force air through the unit to remove the heat created when it is charging the battery and supplying electrical power for the vehicle. ...
IEMD Programming Manual - TDK
... eight control wires and eight ground wires. If the system runs from a personal computer, there are numerous vendors of IEEE controller cards and software. The IEEE-488 standard has gone through several upgrades. The IEEE-488.1 focused on the handshaking of the eight control lines. The IEEE-488.2 add ...
... eight control wires and eight ground wires. If the system runs from a personal computer, there are numerous vendors of IEEE controller cards and software. The IEEE-488 standard has gone through several upgrades. The IEEE-488.1 focused on the handshaking of the eight control lines. The IEEE-488.2 add ...
Comanche Peak Nuclear Power Plant, Units 3 & 4 COL Application
... plant switching station is connected to the transmission grid by four outgoing transmission lines. The one line diagram of the offsite power system is shown in Figure 8.2-202. The plant switching station has two independent control houses (#1 and #2) that contain the control and protection equipment ...
... plant switching station is connected to the transmission grid by four outgoing transmission lines. The one line diagram of the offsite power system is shown in Figure 8.2-202. The plant switching station has two independent control houses (#1 and #2) that contain the control and protection equipment ...
LSK489 Applica on Note
... important to recognize that the channel is not ac ng like a resistor in the satura on region where JFETs are usually operated. The channel is opera ng as a doped semiconductor whose conduc on region is pinched off by surrounding depl on regions to the point where the current is self-limi ng. Conduc o ...
... important to recognize that the channel is not ac ng like a resistor in the satura on region where JFETs are usually operated. The channel is opera ng as a doped semiconductor whose conduc on region is pinched off by surrounding depl on regions to the point where the current is self-limi ng. Conduc o ...
AM26LV31 数据资料 dataSheet 下载
... The AM26LV31C and AM26LV31I are BiCMOS quadruple differential line drivers with 3-state outputs. They are designed to be similar to TIA/EIA-422-B and ITU Recommendation V.11 drivers with reduced supply-voltage range. The devices are optimized for balanced-bus transmission at switching rates up to 32 ...
... The AM26LV31C and AM26LV31I are BiCMOS quadruple differential line drivers with 3-state outputs. They are designed to be similar to TIA/EIA-422-B and ITU Recommendation V.11 drivers with reduced supply-voltage range. The devices are optimized for balanced-bus transmission at switching rates up to 32 ...
Word - Cooper Industries
... Under-oil cartridge fusing shall be utilized (available up to 208 amps of fullload transformer current, up to 34.5 kV delta). The high-voltage overcurrent protection scheme provided with the transformer shall be under-oil cartridge fusing. Cartridge fuses shall be in series with ELSP under-oil par ...
... Under-oil cartridge fusing shall be utilized (available up to 208 amps of fullload transformer current, up to 34.5 kV delta). The high-voltage overcurrent protection scheme provided with the transformer shall be under-oil cartridge fusing. Cartridge fuses shall be in series with ELSP under-oil par ...
Users Manual - Test Equipment Depot
... The meter complies with EN61010, ANSI/ISA S82.011994 and CAN/CSA C22.2 No. 1010.1-92 Overvoltage Category III. Use the meter only as specified in this manual, otherwise the protection provided by the meter may be impaired. A Warning identifies conditions and actions that pose hazard(s) to the user; ...
... The meter complies with EN61010, ANSI/ISA S82.011994 and CAN/CSA C22.2 No. 1010.1-92 Overvoltage Category III. Use the meter only as specified in this manual, otherwise the protection provided by the meter may be impaired. A Warning identifies conditions and actions that pose hazard(s) to the user; ...
Onboard impedance diagnostics method of Li- ion traction batteries using pseudo-random
... batteries and how it affects their health. Especially when the high cost of the automotive application of Li-ion batteries is taken into account, one can understand the importance of being able to use a battery pack of the vehicle to its fullest potential, either if one sees it from the producer's o ...
... batteries and how it affects their health. Especially when the high cost of the automotive application of Li-ion batteries is taken into account, one can understand the importance of being able to use a battery pack of the vehicle to its fullest potential, either if one sees it from the producer's o ...
MAX4402AUA-T中文资料
... 5-pin SC70 and space-saving 5-pin SOT23 packages.oRail-to-Rail Output Voltage SwingThe single MAX4401 includes the shutdown feature and iso1.4mA of Sink and Source Load Currentavailable in a 6-pin SC70. The MAX4402 is a dual amplifieravailable in 8-pin SOT23 and SO packages. TheoUnity-Gain Stable up ...
... 5-pin SC70 and space-saving 5-pin SOT23 packages.oRail-to-Rail Output Voltage SwingThe single MAX4401 includes the shutdown feature and iso1.4mA of Sink and Source Load Currentavailable in a 6-pin SC70. The MAX4402 is a dual amplifieravailable in 8-pin SOT23 and SO packages. TheoUnity-Gain Stable up ...
PDF
... Under-oil cartridge fusing shall be utilized (available up to 208 amps of fullload transformer current, up to 34.5 kV delta). The high-voltage overcurrent protection scheme provided with the transformer shall be under-oil cartridge fusing. Cartridge fuses shall be in series with ELSP under-oil par ...
... Under-oil cartridge fusing shall be utilized (available up to 208 amps of fullload transformer current, up to 34.5 kV delta). The high-voltage overcurrent protection scheme provided with the transformer shall be under-oil cartridge fusing. Cartridge fuses shall be in series with ELSP under-oil par ...
Electrical Safety World Teacher`s Guide
... It’s just the nature of electricity to move from an area of higher voltage to an area of lower voltage, if given a path to travel there. The ground is simply the lowest-voltage area around, so if you give electricity a path to the ground, it will take it, no questions asked! When electricity goes in ...
... It’s just the nature of electricity to move from an area of higher voltage to an area of lower voltage, if given a path to travel there. The ground is simply the lowest-voltage area around, so if you give electricity a path to the ground, it will take it, no questions asked! When electricity goes in ...
Alternating current
Alternating current (AC), is an electric current in which the flow of electric charge periodically reverses direction, whereas in direct current (DC, also dc), the flow of electric charge is only in one direction. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.AC is the form in which electric power is delivered to businesses and residences. The usual waveform of alternating current in most electric power circuits is a sine wave. In certain applications, different waveforms are used, such as triangular or square waves. Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information encoded (or modulated) onto the AC signal, such as sound (audio) or images (video).