Onboard impedance diagnostics method of Li- ion traction batteries using pseudo-random
... batteries and how it affects their health. Especially when the high cost of the automotive application of Li-ion batteries is taken into account, one can understand the importance of being able to use a battery pack of the vehicle to its fullest potential, either if one sees it from the producer's o ...
... batteries and how it affects their health. Especially when the high cost of the automotive application of Li-ion batteries is taken into account, one can understand the importance of being able to use a battery pack of the vehicle to its fullest potential, either if one sees it from the producer's o ...
MAX4402AUA-T中文资料
... 5-pin SC70 and space-saving 5-pin SOT23 packages.oRail-to-Rail Output Voltage SwingThe single MAX4401 includes the shutdown feature and iso1.4mA of Sink and Source Load Currentavailable in a 6-pin SC70. The MAX4402 is a dual amplifieravailable in 8-pin SOT23 and SO packages. TheoUnity-Gain Stable up ...
... 5-pin SC70 and space-saving 5-pin SOT23 packages.oRail-to-Rail Output Voltage SwingThe single MAX4401 includes the shutdown feature and iso1.4mA of Sink and Source Load Currentavailable in a 6-pin SC70. The MAX4402 is a dual amplifieravailable in 8-pin SOT23 and SO packages. TheoUnity-Gain Stable up ...
Users Manual - Test Equipment Depot
... The meter complies with EN61010, ANSI/ISA S82.011994 and CAN/CSA C22.2 No. 1010.1-92 Overvoltage Category III. Use the meter only as specified in this manual, otherwise the protection provided by the meter may be impaired. A Warning identifies conditions and actions that pose hazard(s) to the user; ...
... The meter complies with EN61010, ANSI/ISA S82.011994 and CAN/CSA C22.2 No. 1010.1-92 Overvoltage Category III. Use the meter only as specified in this manual, otherwise the protection provided by the meter may be impaired. A Warning identifies conditions and actions that pose hazard(s) to the user; ...
User`s manual ATV18 - Variateur de vitesse
... Painted steel can be used on condition that good electrical contact is ensured between the mounting surfaces with 2 and 5. 2- Altivar 18 fixed directly to the mounting plate (equipotential grounds). 3- Non-shielded supply wires or cable for connecting the line choke, if used. 4- Non-shielded wires f ...
... Painted steel can be used on condition that good electrical contact is ensured between the mounting surfaces with 2 and 5. 2- Altivar 18 fixed directly to the mounting plate (equipotential grounds). 3- Non-shielded supply wires or cable for connecting the line choke, if used. 4- Non-shielded wires f ...
BBC Bracket Instructions2
... Tighten nut with impact wrench until lock washer is completely closed and nut is tight. ...
... Tighten nut with impact wrench until lock washer is completely closed and nut is tight. ...
Schneider Electric Altivar ATV18
... Painted steel can be used on condition that good electrical contact is ensured between the mounting surfaces with 2 and 5. 2- Altivar 18 fixed directly to the mounting plate (equipotential grounds). 3- Non-shielded supply wires or cable for connecting the line choke, if used. 4- Non-shielded wires f ...
... Painted steel can be used on condition that good electrical contact is ensured between the mounting surfaces with 2 and 5. 2- Altivar 18 fixed directly to the mounting plate (equipotential grounds). 3- Non-shielded supply wires or cable for connecting the line choke, if used. 4- Non-shielded wires f ...
An 80-Tile Sub-100-W TeraFLOPS Processor in 65
... multiprocessors include the RAW [3], TRIPS [4], and ASAP [5] projects. These tiled architectures show promise for greater integration, high performance, good scalability and potentially high energy efficiency. With the increasing demand for interconnect bandwidth, on-chip networks are taking up a su ...
... multiprocessors include the RAW [3], TRIPS [4], and ASAP [5] projects. These tiled architectures show promise for greater integration, high performance, good scalability and potentially high energy efficiency. With the increasing demand for interconnect bandwidth, on-chip networks are taking up a su ...
TQP4M9071 数据资料DataSheet下载
... The TQP4M9071 is a high linearity, low insertion loss, wideband, 6-bit, 31.5 dB digital step attenuator. The digital step attenuator uses a single 3.3V or 5V supply and has a parallel control interface for changing attenuation states. This product maintains high attenuation accuracy over frequency a ...
... The TQP4M9071 is a high linearity, low insertion loss, wideband, 6-bit, 31.5 dB digital step attenuator. The digital step attenuator uses a single 3.3V or 5V supply and has a parallel control interface for changing attenuation states. This product maintains high attenuation accuracy over frequency a ...
XC2301 Series:DATA SHEET
... before use, to confirm that the information in this datasheet is up to date. 2. We assume no responsibility for any infringement of patents, patent rights, or other rights arising from the use of any information and circuitry in this datasheet. 3. Please ensure suitable shipping controls (including ...
... before use, to confirm that the information in this datasheet is up to date. 2. We assume no responsibility for any infringement of patents, patent rights, or other rights arising from the use of any information and circuitry in this datasheet. 3. Please ensure suitable shipping controls (including ...
MB88153A MB88153A
... A latch-up can occur if, on this device, (a) a voltage higher than VDD or a voltage lower than VSS is applied to an input or output pin or (b) a voltage higher than the rating is applied between VDD pin and VSS pin. The latch-up, if it occurs, significantly increases the power supply current and may ...
... A latch-up can occur if, on this device, (a) a voltage higher than VDD or a voltage lower than VSS is applied to an input or output pin or (b) a voltage higher than the rating is applied between VDD pin and VSS pin. The latch-up, if it occurs, significantly increases the power supply current and may ...
REGULATORY GUIDE
... load interruption. Large induction motors can achieve rated speed in less than 5 seconds when powered from adequately sized emergency diesel generators that are capable of restoring the bus voltage to 90 percent of nominal in about 1–2 second(s). Protection of the emergency diesel generator from exc ...
... load interruption. Large induction motors can achieve rated speed in less than 5 seconds when powered from adequately sized emergency diesel generators that are capable of restoring the bus voltage to 90 percent of nominal in about 1–2 second(s). Protection of the emergency diesel generator from exc ...
CE/SC 12
... 12-01 Switching Impulse and Lighting Impulse Strengths of Oil-Immersed Insulation Structures and the Relevance of these Comparisons to Service and Test Voltage Requirements of Transformers. 12-02 The Analysis of Gases Dissolved in the Oil as a Means of Monitoring Transformers and Detecting Incipient ...
... 12-01 Switching Impulse and Lighting Impulse Strengths of Oil-Immersed Insulation Structures and the Relevance of these Comparisons to Service and Test Voltage Requirements of Transformers. 12-02 The Analysis of Gases Dissolved in the Oil as a Means of Monitoring Transformers and Detecting Incipient ...
12 02-13
... 1. Disconnect line heater 5 harness connector. Refer to Original Equipment Manufacturer (OEM) literature for schematic information. 2. Inspect the harness connector for signs of damaged, bent, spread, corroded or unseated (pushed out) pins and signs of moisture in the connector or wire damage near t ...
... 1. Disconnect line heater 5 harness connector. Refer to Original Equipment Manufacturer (OEM) literature for schematic information. 2. Inspect the harness connector for signs of damaged, bent, spread, corroded or unseated (pushed out) pins and signs of moisture in the connector or wire damage near t ...
Medium Voltage Power System Maintenance
... DC hipot test utilizing voltage step method as specified for cables in Article 3.2 of this Section. Maximum test levels shall be withstand, held for not less than one ...
... DC hipot test utilizing voltage step method as specified for cables in Article 3.2 of this Section. Maximum test levels shall be withstand, held for not less than one ...
Wind turbine power generation emulation via doubly fed induction
... rotor speed using a Proportional Integral Controller (PI). It is important to show that we can control the DFIG rotor speed since traditional Wind Turbine Generators would use turbine blade pitch control in tandem with a synchronous generator to provide a constant speed, and hence a constant output ...
... rotor speed using a Proportional Integral Controller (PI). It is important to show that we can control the DFIG rotor speed since traditional Wind Turbine Generators would use turbine blade pitch control in tandem with a synchronous generator to provide a constant speed, and hence a constant output ...
Smart swimming pool controller with intelligent sensors
... The aim of the project was to develop a system that can monitor the swimming pool entities closely and keep the user updated all the time. The primary focus was the issue of energy saving which is one of the major concerns in South Africa and the world at large. Various sensors were implemented to d ...
... The aim of the project was to develop a system that can monitor the swimming pool entities closely and keep the user updated all the time. The primary focus was the issue of energy saving which is one of the major concerns in South Africa and the world at large. Various sensors were implemented to d ...
HMC347G8 数据资料DataSheet下载
... [1] Reference this number when ordering complete evaluation PCB [2] Circuit Board Material: Rogers 4350 ...
... [1] Reference this number when ordering complete evaluation PCB [2] Circuit Board Material: Rogers 4350 ...
Microwave Amplifiers
... For instance if the amplifier is required to drive 50Ω load the voltage across the load may be small, although the corresponding current may be large (there is current gain). For amplifiers functioning at lower frequency (such as IF frequency), it is the voltage gain that is of interest, since imped ...
... For instance if the amplifier is required to drive 50Ω load the voltage across the load may be small, although the corresponding current may be large (there is current gain). For amplifiers functioning at lower frequency (such as IF frequency), it is the voltage gain that is of interest, since imped ...
Generlink - Your Path to Power
... panel require rewiring of the household electrical system and limit the number of circuits that can be powered by the portable generator. GenerLink offers several advantages over traditional a transfer switch and sub panel: 1. GenerLink is installed outside your home at the electric meter in less th ...
... panel require rewiring of the household electrical system and limit the number of circuits that can be powered by the portable generator. GenerLink offers several advantages over traditional a transfer switch and sub panel: 1. GenerLink is installed outside your home at the electric meter in less th ...
Alternating current
Alternating current (AC), is an electric current in which the flow of electric charge periodically reverses direction, whereas in direct current (DC, also dc), the flow of electric charge is only in one direction. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.AC is the form in which electric power is delivered to businesses and residences. The usual waveform of alternating current in most electric power circuits is a sine wave. In certain applications, different waveforms are used, such as triangular or square waves. Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information encoded (or modulated) onto the AC signal, such as sound (audio) or images (video).