CY7C65100 Four-port Universal Serial Bus Fixed
... to these pins. A 6-MHz fundamental crystal can be connected to these pins to provide a reference frequency for the internal PLL. When using an external crystal, keep PCB traces between the chip leads and crystal as short as possible (less than 2 cm). A ceramic resonator is not an adequate clock sour ...
... to these pins. A 6-MHz fundamental crystal can be connected to these pins to provide a reference frequency for the internal PLL. When using an external crystal, keep PCB traces between the chip leads and crystal as short as possible (less than 2 cm). A ceramic resonator is not an adequate clock sour ...
MAX2021EVKIT.pdf
... general precaution to prevent damaging the outputs by driving high VSWR loads, do not turn on DC power or RF signal generators until all connections are made. This upconverter procedure is general to operation with an I/Q baseband input signal at 1MHz. Choose the test frequency based on the particul ...
... general precaution to prevent damaging the outputs by driving high VSWR loads, do not turn on DC power or RF signal generators until all connections are made. This upconverter procedure is general to operation with an I/Q baseband input signal at 1MHz. Choose the test frequency based on the particul ...
TSC2003-Q1 数据资料 dataSheet 下载
... DESCRIPTION The TSC2003 is a 4-wire resistive touch screen controller. It also features direct measurement of two batteries, two auxiliary analog inputs, temperature measurement, and touch-pressure measurement. The TSC2003 has an on-chip 2.5-V reference that can be utilized for the auxiliary inputs, ...
... DESCRIPTION The TSC2003 is a 4-wire resistive touch screen controller. It also features direct measurement of two batteries, two auxiliary analog inputs, temperature measurement, and touch-pressure measurement. The TSC2003 has an on-chip 2.5-V reference that can be utilized for the auxiliary inputs, ...
PIC16F87X Development unit
... The PIC16F87X development unit is ideal for the development of embedded systems based the PIC family of processors. It allows for the quick development and testing of software. The strip-board area is well suited to the development of interfacing circuitry. These features allow for quick prototyping ...
... The PIC16F87X development unit is ideal for the development of embedded systems based the PIC family of processors. It allows for the quick development and testing of software. The strip-board area is well suited to the development of interfacing circuitry. These features allow for quick prototyping ...
IEEE NSS LST OSU HV System - OSU Physics
... BaBar Limited Streamer Tubes (LSTs): – Tubes with 7 or 8 wires (cells) – Cells are (1.75x1.75)cm2 and 358cm long – Wires coupled in 4 HV channels per tube – The 4 HV channels are readout channels – Operated at 5500V, with Ar/Iso/CO2 ...
... BaBar Limited Streamer Tubes (LSTs): – Tubes with 7 or 8 wires (cells) – Cells are (1.75x1.75)cm2 and 358cm long – Wires coupled in 4 HV channels per tube – The 4 HV channels are readout channels – Operated at 5500V, with Ar/Iso/CO2 ...
Making Sense Of Oxygen Sensors
... O2 sensor performance diminishes with age as contaminants accumulate on the sensor tip and gradually reduce its ability to produce voltage. The sensor becomes sluggish and takes longer to react to oxygen changes in the exhaust causing emissions and fuel consumption to go up. The effect is most notic ...
... O2 sensor performance diminishes with age as contaminants accumulate on the sensor tip and gradually reduce its ability to produce voltage. The sensor becomes sluggish and takes longer to react to oxygen changes in the exhaust causing emissions and fuel consumption to go up. The effect is most notic ...
BD00IA5MEFJ-LB
... can break down the devices, thus making impossible to identify breaking mode, such as a short circuit or an open circuit. If any over rated values will expect to exceed the absolute maximum ratings, consider adding circuit protection devices, such as fuses. (2). Connecting the power supply connector ...
... can break down the devices, thus making impossible to identify breaking mode, such as a short circuit or an open circuit. If any over rated values will expect to exceed the absolute maximum ratings, consider adding circuit protection devices, such as fuses. (2). Connecting the power supply connector ...
Board-Level Considerations
... located on the input and output of every logic module. During power-up, this charge pump turns on the isolation transistors, allowing the logic array and I/Os to function according to the design. The exact behavior is a function of both power-up sequence and ramp rate. SoC Products Group devices hav ...
... located on the input and output of every logic module. During power-up, this charge pump turns on the isolation transistors, allowing the logic array and I/Os to function according to the design. The exact behavior is a function of both power-up sequence and ramp rate. SoC Products Group devices hav ...
Grounding and Bonding - Peck Ormsby Construction
... both ends of metallic conduit runs. Bond ground bushings to the grounding system. ...
... both ends of metallic conduit runs. Bond ground bushings to the grounding system. ...
specifications for centrifugal pump and fan applications
... NOTE: These specifications apply to Enclosed Adjustable Frequency Drive Controllers, herein referred to as AC Drives. The Power Converter is a component of the AC Drive. To ensure project compatibility, these specifications follow the Construction Specifications Institute (CSI) format. Copies of thi ...
... NOTE: These specifications apply to Enclosed Adjustable Frequency Drive Controllers, herein referred to as AC Drives. The Power Converter is a component of the AC Drive. To ensure project compatibility, these specifications follow the Construction Specifications Institute (CSI) format. Copies of thi ...
MN225014EN/ Old S225-10-10PSVR
... voltage levels within programmed limits to improve power quality and are compatible with SCADA and automation distribution systems. Available in single-phase, 2-in-1 and 3-in-1 configurations, Eaton's pad-mounted voltage regulators are suitable for three- or four-wire underground systems. The 2-in-1 ...
... voltage levels within programmed limits to improve power quality and are compatible with SCADA and automation distribution systems. Available in single-phase, 2-in-1 and 3-in-1 configurations, Eaton's pad-mounted voltage regulators are suitable for three- or four-wire underground systems. The 2-in-1 ...
Fluke 120B Series Industrial ScopeMeter® Hand
... or displacement power factor (DPF) and can also calculate the power values for a 3-phase system where all phases have equal voltage and currents. This applies to both balanced system and resistive loads. ...
... or displacement power factor (DPF) and can also calculate the power values for a 3-phase system where all phases have equal voltage and currents. This applies to both balanced system and resistive loads. ...
CE/SC 12
... 12-01 Switching Impulse and Lighting Impulse Strengths of Oil-Immersed Insulation Structures and the Relevance of these Comparisons to Service and Test Voltage Requirements of Transformers. 12-02 The Analysis of Gases Dissolved in the Oil as a Means of Monitoring Transformers and Detecting Incipient ...
... 12-01 Switching Impulse and Lighting Impulse Strengths of Oil-Immersed Insulation Structures and the Relevance of these Comparisons to Service and Test Voltage Requirements of Transformers. 12-02 The Analysis of Gases Dissolved in the Oil as a Means of Monitoring Transformers and Detecting Incipient ...
Guide and Requirements for Service at 69000 to 287000
... SECTION 3.0 - CUSTOMER ELECTRICAL REQUIREMENTS SUBSECTION 3.1 - EQUIPMENT REQUIREMENTS It will be necessary for customers to coordinate their station insulation with the incoming transmission line insulation. At 230 kV and 287 kV it is BC Hydro's practice to install overhead ground wires on transmis ...
... SECTION 3.0 - CUSTOMER ELECTRICAL REQUIREMENTS SUBSECTION 3.1 - EQUIPMENT REQUIREMENTS It will be necessary for customers to coordinate their station insulation with the incoming transmission line insulation. At 230 kV and 287 kV it is BC Hydro's practice to install overhead ground wires on transmis ...
Amplificador de potência cmos em 2.4 ghz com potência de saída
... Settings of the highlighted upper transistor are shown in the object properties box. Note that the field “Width all fingers” is set with the value “WTA”, an example of parameterization for optimization simulation. ...................................................................................... ...
... Settings of the highlighted upper transistor are shown in the object properties box. Note that the field “Width all fingers” is set with the value “WTA”, an example of parameterization for optimization simulation. ...................................................................................... ...
Alternating current
Alternating current (AC), is an electric current in which the flow of electric charge periodically reverses direction, whereas in direct current (DC, also dc), the flow of electric charge is only in one direction. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.AC is the form in which electric power is delivered to businesses and residences. The usual waveform of alternating current in most electric power circuits is a sine wave. In certain applications, different waveforms are used, such as triangular or square waves. Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information encoded (or modulated) onto the AC signal, such as sound (audio) or images (video).