• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Electronics in Motion and Conversion May 2015
Electronics in Motion and Conversion May 2015

PEQWS_Mod01_Prob04_v03 - Courses
PEQWS_Mod01_Prob04_v03 - Courses

... Note: Some students would contend that we have defined the reference polarity of the current in this problem incorrectly. This is not the way we want to think about these problems. By our definitions, one cannot define reference polarities incorrectly. What we have done is define the reference polar ...
TB2014-002 e3 Transorb Installation Instructions.indd
TB2014-002 e3 Transorb Installation Instructions.indd

... parallel with the lock wiring. This applies to both AC and DC locks. Four (4) transorbs are included with each e3 system. DO NOT discard these important devices. Install a transorb to the door lock relay connector in the same terminal positions as the lock wiring. The Type SA48C transorbs supplied a ...
Commande Vectorielle Non Linéaire de L`onduleur MLI à
Commande Vectorielle Non Linéaire de L`onduleur MLI à

... current which the active filter must supply [10]. This reference current is fed through a controller and then the switching signal is generated to switch the power switching devices of the active filter such that the active filter will indeed produce the harmonics required by the load. Finally, the ...
Design Project - Purdue Engineering
Design Project - Purdue Engineering

Engineering Solutions for the Electro-polishing of Multi
Engineering Solutions for the Electro-polishing of Multi

... of 150dm². The available power supply delivers a ripple filtered DC voltage of 40V and a current of 1500A at maximum. The voltage can be regulated and for the current it is possible to set an upper limit. The remaining 50Hz ripple from the grid is kept below 1%. Since the system will be run first wi ...
Voltage Rectification by a SQUID Ratchet - Physik Uni
Voltage Rectification by a SQUID Ratchet - Physik Uni

Chapter 14 Inductive Transients
Chapter 14 Inductive Transients

... Given E=50V, R=10, and L=2H, determine i(t). ...
S1-P210
S1-P210

FP5000 Feeder Protection
FP5000 Feeder Protection

Demagnetisation of CT cores under exposure of operating currents
Demagnetisation of CT cores under exposure of operating currents

... scaling, the approximate course of the residual magnetism over the applied current can be constructed. The current value on the horizontal axis is referred to I max, which is the peak value of the sinusoidal current applied. During the positive half wave of the current, the magnetisation curve descr ...
Comparison of Electric Springs with STATCOM for
Comparison of Electric Springs with STATCOM for

Op-amp Voltage Comparator
Op-amp Voltage Comparator

...  With the help of the calibrated oscilloscope, Y-X mode, you will see VTC vO(vI), applying to the two inputs X and Y of the oscilloscope the two voltages vI(t) and respectively vO(t).  You will visualize VTC for VREF = 4V  You will visualize VTC for VREF = - 4V C. The effects of modifying the sup ...
GR 804-B UHF Signal Generator, Manual
GR 804-B UHF Signal Generator, Manual

... This meter ·iS a co·-er-oxide-rectifier type meter of 7 . 5 volts full scale , which is connected to about one-tenth of the turns of the modulation choke ~ · In the EXT. position of the modulation switch the modulator tube acts as an amplifier with the modulation potentiometer as the plate load. Cha ...
Technical Basics - 2
Technical Basics - 2

... Diodes Give DC Conversion ...
Ratioed Circuits
Ratioed Circuits

NCP1532GEVB NCP1532 Dual Output Step-down Converter Evaluation Board User's
NCP1532GEVB NCP1532 Dual Output Step-down Converter Evaluation Board User's

... efficiency. The device can also operate into fixed frequency PWM mode for low noise applications where low ripple and good load transients are required. Additional features include integrated soft−start, cycle−by−cycle current limit and thermal shutdown protection. The device can also be synchronize ...
LM392 - Texas Instruments
LM392 - Texas Instruments

High-efficiency power conversion with silicon
High-efficiency power conversion with silicon

... silicon IGBTs and fast recovery diodes, or emerging devices, typically the silicon carbide (SiC) MOSFET. ...
Single Diode, 600 V, 10 A
Single Diode, 600 V, 10 A

... grant any guarantee thereof. If you should intend to use our products for new introduction or other application different from current conditions on the usage of automotive device, communication device, office equipment, industrial equipment etc. , please consult with us about usage condition (tempe ...
W. Li, N. Salazar and D.J. Perreault, “Integrated Low
W. Li, N. Salazar and D.J. Perreault, “Integrated Low

... Westinghouse and Thomas Edison became adversaries due to Edison’s promotion of low-voltage direct current (dc) for the electric power distribution over alternating current (ac) supported by Westinghouse [7]. However, Edison’s dc system suffered two major disadvantages: 1. The distribution range was ...
Abstract - The University of Texas at El Paso
Abstract - The University of Texas at El Paso

... A mixer converts a signal from one frequency ωRF to another frequency ωIF with a certain gain. It receives the RF signal directly from the LNA, or from a filter –depending on the receiver architecture, and performs frequency translation by multiplying it with that of a local oscillator (LO) and thei ...
Evaluates: MAX1982/MAX1983 MAX1982 Evaluation Kit General Description Features
Evaluates: MAX1982/MAX1983 MAX1982 Evaluation Kit General Description Features

... The MAX1982 evaluation kit (EV kit) provides a regulated 1.2V output voltage while operating on input voltages from 1.25V to 5.5V. It delivers a 0.3A output current from a 1.25V to 2.5V input, with less than 300mV dropout. Operation with higher input voltages (up to 5.5V) is possible as long as the ...
Inductive Load Arc Suppression
Inductive Load Arc Suppression

OPA341 OPA2341 SINGLE-SUPPLY, RAIL-TO-RAIL OPERATIONAL AMPLIFIER WITH SHUTDOWN
OPA341 OPA2341 SINGLE-SUPPLY, RAIL-TO-RAIL OPERATIONAL AMPLIFIER WITH SHUTDOWN

... The OPA341 implements a power-saving shutdown feature particularly useful for low-power sampling applications. Figure 5 shows the OPA341 driving the ADS7816, a 12-bit micro-power sampling converter available in the tiny MSOP-8 package. With the OPA341 in non-inverting configuration, an RC network at ...
< 1 ... 1335 1336 1337 1338 1339 1340 1341 1342 1343 ... 2014 >

Alternating current



Alternating current (AC), is an electric current in which the flow of electric charge periodically reverses direction, whereas in direct current (DC, also dc), the flow of electric charge is only in one direction. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.AC is the form in which electric power is delivered to businesses and residences. The usual waveform of alternating current in most electric power circuits is a sine wave. In certain applications, different waveforms are used, such as triangular or square waves. Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information encoded (or modulated) onto the AC signal, such as sound (audio) or images (video).
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report