
SN65MLVD048 数据资料 dataSheet 下载
... channel is controlled by a receive enable (RE). When RE = low, the corresponding channel is enabled; when RE = high, the corresponding channel is disabled. The M-LVDS standard defines two types of receivers, designated as Type-1 and Type-2. Type-1 receivers have thresholds centered about zero with 2 ...
... channel is controlled by a receive enable (RE). When RE = low, the corresponding channel is enabled; when RE = high, the corresponding channel is disabled. The M-LVDS standard defines two types of receivers, designated as Type-1 and Type-2. Type-1 receivers have thresholds centered about zero with 2 ...
Pulse generator for sweep calibration - K-REx
... various wave forms from a television synchronous generator, the pulses would have to be initiated at a desired point on the signal wave in order that close comparisons could be made. ...
... various wave forms from a television synchronous generator, the pulses would have to be initiated at a desired point on the signal wave in order that close comparisons could be made. ...
2EM Ohm`s Law and Simple DC Circuits
... Vary the potential difference applied to the circuit by turning the knob of the potential divider. Record the current I for at least eight different values of the potential difference V between 0 and 4 volts. Repeat this process for the orange resistor, the blue and orange resistors in series, and ...
... Vary the potential difference applied to the circuit by turning the knob of the potential divider. Record the current I for at least eight different values of the potential difference V between 0 and 4 volts. Repeat this process for the orange resistor, the blue and orange resistors in series, and ...
1. Define binary logic? Binary logic consists of binary variables and
... Binary logic consists of binary variables and logical operations. The variables are designated by the alphabets such as A, B, C, x, y, z, etc., with each variable having only two distinct values: 1 and 0. There are three basic logic operations: AND, OR, and NOT. 2. What are the basic digital logic g ...
... Binary logic consists of binary variables and logical operations. The variables are designated by the alphabets such as A, B, C, x, y, z, etc., with each variable having only two distinct values: 1 and 0. There are three basic logic operations: AND, OR, and NOT. 2. What are the basic digital logic g ...
CD74HC4051-EP Analog Multiplexer
... In certain applications, the external load resistor current may include both VCC and signal-line components. To avoid drawing VCC current when switch current flows into the transmission gate inputs, the voltage drop across the bidirectional switch must not exceed 0.6 V (calculated from ron values sh ...
... In certain applications, the external load resistor current may include both VCC and signal-line components. To avoid drawing VCC current when switch current flows into the transmission gate inputs, the voltage drop across the bidirectional switch must not exceed 0.6 V (calculated from ron values sh ...
BDTIC CoolSET™ F3R80 ICE3AR4780VJZ
... All values which are used in the functional description are typical values. For calculating the worst cases the min/max values which can be found in section 4 Electrical Characteristics have to be considered. ...
... All values which are used in the functional description are typical values. For calculating the worst cases the min/max values which can be found in section 4 Electrical Characteristics have to be considered. ...
LTC3559
... can toggle between low power and high power modes per USB specification. A weak pull-down current is internally applied to this pin to ensure it is low at power up when the input is not being driven externally. NTC (Pin 13): Input to the NTC Thermistor Monitoring Circuit. The NTC pin connects to a ne ...
... can toggle between low power and high power modes per USB specification. A weak pull-down current is internally applied to this pin to ensure it is low at power up when the input is not being driven externally. NTC (Pin 13): Input to the NTC Thermistor Monitoring Circuit. The NTC pin connects to a ne ...
P82478
... The AMT Multitone Strobe Appliance are UL Listed under Standard 1971 for Emergency Appliances for the Hearing Impaired and UL Standard 464 for Audible Appliances. They are listed for indoor use only with the backboxes specified in these instructions (See Mounting Options). Models with LS and IS stro ...
... The AMT Multitone Strobe Appliance are UL Listed under Standard 1971 for Emergency Appliances for the Hearing Impaired and UL Standard 464 for Audible Appliances. They are listed for indoor use only with the backboxes specified in these instructions (See Mounting Options). Models with LS and IS stro ...
A RESONANT INVERTER AS A CONTROLLED REACTANCE
... loaded by a resonant tank can be used to emulate a capacitive or inductive reactance. The magnitude of the reactance can be controlled by changing the switching frequency or by applying PWM. An apparent resonant phenomenon, "commutator resonance", is discovered and its dependence on the topology ele ...
... loaded by a resonant tank can be used to emulate a capacitive or inductive reactance. The magnitude of the reactance can be controlled by changing the switching frequency or by applying PWM. An apparent resonant phenomenon, "commutator resonance", is discovered and its dependence on the topology ele ...
Short-circuit - analysis and calculation
... circuit power, positive sequence short-circuit impedance matrix, negative sequence short-circuit impedance matrix, zero sequence short-circuit impedance matrix incurred a damage or deformation of electrical, mechanical or thermal character. It is therefore necessary, due to the dangerous effects of ...
... circuit power, positive sequence short-circuit impedance matrix, negative sequence short-circuit impedance matrix, zero sequence short-circuit impedance matrix incurred a damage or deformation of electrical, mechanical or thermal character. It is therefore necessary, due to the dangerous effects of ...
TDA8950 2 x 150 W class-D power amplifier - Rcl
... n Stereo full differential inputs, usable as stereo Single-Ended (SE) or mono Bridge-Tied Load (BTL) amplifier n High output power at typical applications: u SE 2 × 150 W, RL = 4 Ω (VP = ±37 V) u SE 2 × 170 W, RL = 4 Ω (VP = ±39 V) u SE 2 × 100 W, RL = 6 Ω (VP = ±37 V) ...
... n Stereo full differential inputs, usable as stereo Single-Ended (SE) or mono Bridge-Tied Load (BTL) amplifier n High output power at typical applications: u SE 2 × 150 W, RL = 4 Ω (VP = ±37 V) u SE 2 × 170 W, RL = 4 Ω (VP = ±39 V) u SE 2 × 100 W, RL = 6 Ω (VP = ±37 V) ...
Ch21CT
... Answer: No net torque and no net force. Using the right hand rule for each side of the square loop, the force on each side is away from the center of the loop. The net force and net torque are both zero. ...
... Answer: No net torque and no net force. Using the right hand rule for each side of the square loop, the force on each side is away from the center of the loop. The net force and net torque are both zero. ...
Principles of Technology
... chapter. In addition, they may include additional power sources, current loops, and junctions. These complex circuits will not be analyzed in this book. You should be aware, however, that Kirchhoff’s rules and some fancy algebra can be used for these analyses. Ask your physics teacher to show you ho ...
... chapter. In addition, they may include additional power sources, current loops, and junctions. These complex circuits will not be analyzed in this book. You should be aware, however, that Kirchhoff’s rules and some fancy algebra can be used for these analyses. Ask your physics teacher to show you ho ...
LN Series Input/Output (I/O) Extension Modules Installation Instructions
... you connect the controllers and devices to the transformer. IMPORTANT: One terminal on the secondary side of the transformer must be connected to the building’s ground. All 24 V COM terminals of all controllers and peripherals throughout the LAN or the subnetwork must be connected to the grounded tr ...
... you connect the controllers and devices to the transformer. IMPORTANT: One terminal on the secondary side of the transformer must be connected to the building’s ground. All 24 V COM terminals of all controllers and peripherals throughout the LAN or the subnetwork must be connected to the grounded tr ...
HMC724LC3
... inputs and outputs are DC coupled and terminated on chip with 50 Ohm resistors to ground. The outputs may be used in either single ended or differential modes, and should be AC or DC coupled into 50 Ohm resistors connected to ground. All differential inputs to the HMC724LC3 are CML and terminated on ...
... inputs and outputs are DC coupled and terminated on chip with 50 Ohm resistors to ground. The outputs may be used in either single ended or differential modes, and should be AC or DC coupled into 50 Ohm resistors connected to ground. All differential inputs to the HMC724LC3 are CML and terminated on ...
$doc.title
... † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to ...
... † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to ...