WECC-0100 TPL-001-WECC-CRT-3 Response to Comment
... study parameter coupled with a unique nominal value, established by the Transmission Planner and the Planning Coordinator, to be used in the absence of either a more stringent or less stringent study parameter. In the context of this document the word “nominal” carries its common definition and is t ...
... study parameter coupled with a unique nominal value, established by the Transmission Planner and the Planning Coordinator, to be used in the absence of either a more stringent or less stringent study parameter. In the context of this document the word “nominal” carries its common definition and is t ...
High Voltage Power Supply Technology for Use in Power Feed
... than the output voltage rating of the PFE (typically 2x, to ensure high reliability) Output rectifier: Since the application requires a DC source, yes, we need to invert that AC back into DC again. This is accomplished by high speed, high voltage rectifier diodes. (These multiple stages of inversion ...
... than the output voltage rating of the PFE (typically 2x, to ensure high reliability) Output rectifier: Since the application requires a DC source, yes, we need to invert that AC back into DC again. This is accomplished by high speed, high voltage rectifier diodes. (These multiple stages of inversion ...
RF3159 QUAD-BAND GSM/EDGE/GSM850/EGSM900 /DCS/PCS/POWER AMPLIFIER MODULE Features
... Digital Band Select Enables GSM850, EGSM900 or DCS, ...
... Digital Band Select Enables GSM850, EGSM900 or DCS, ...
Harmonic mitigation Solution Handbook
... They are commonly used up to about 500kW unit power or 1,000kW total drives power. In this power range the transformer should be at least 2.5 times the drives load. Depending on the transformer size and cabling, the resulting THDu will be up to ~6%. This could give possible nuisance, but is usually ...
... They are commonly used up to about 500kW unit power or 1,000kW total drives power. In this power range the transformer should be at least 2.5 times the drives load. Depending on the transformer size and cabling, the resulting THDu will be up to ~6%. This could give possible nuisance, but is usually ...
Modeling of Eddy-Current Loss of Electrical Machines and Transformers
... PWM supply is widely used in the speed control of dc motors. The pulsation components in the PWM supply will also induce additional losses. The losses induced by PWM supply include copper loss, hysteresis loss, and eddy-current loss. Among them, eddy-current loss is the dominating loss mechanism acc ...
... PWM supply is widely used in the speed control of dc motors. The pulsation components in the PWM supply will also induce additional losses. The losses induced by PWM supply include copper loss, hysteresis loss, and eddy-current loss. Among them, eddy-current loss is the dominating loss mechanism acc ...
12.1 A Hybrid Multilevel Inverter Topology for Drive
... advantage in the number of levels it can generate with a same number of dc sources and power devices when compared to the conventional configuration. However, it may be noted that the stress on the power device in this configuration is proportional to the voltage level it is used. Hence the devices ...
... advantage in the number of levels it can generate with a same number of dc sources and power devices when compared to the conventional configuration. However, it may be noted that the stress on the power device in this configuration is proportional to the voltage level it is used. Hence the devices ...
SE2521A80 数据资料DataSheet下载
... Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. ...
... Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. ...
Magnetism: quantities, units and relationships
... In the example the field strength is then H = 0.5 / 27.6×10-3 = 18.1 A m-1 The analogy with electric field strength is mathematical and not physical. An electric field has a clearly defined physical meaning: simply the force exerted on a 'test charge' divided by the amount of charge. Magnetic field ...
... In the example the field strength is then H = 0.5 / 27.6×10-3 = 18.1 A m-1 The analogy with electric field strength is mathematical and not physical. An electric field has a clearly defined physical meaning: simply the force exerted on a 'test charge' divided by the amount of charge. Magnetic field ...
selecting and using transducers for the measurement of electric
... TRANSDUCERS AND TRANSFORMERS FOR ELECTRICAL MEASUREMENTS Transducers for electrical measurement are an essential part of any monitoring, measuring, or controlling system where electrical quantities are involved. In order to use these transducers it is important to know what they do, what kind of sig ...
... TRANSDUCERS AND TRANSFORMERS FOR ELECTRICAL MEASUREMENTS Transducers for electrical measurement are an essential part of any monitoring, measuring, or controlling system where electrical quantities are involved. In order to use these transducers it is important to know what they do, what kind of sig ...
SKY77328 数据资料DataSheet下载
... ICC = 0A to xA, where x = current at POUT = 34.5 dBm, 50 Ω load, and VCC = 3.5 V. ...
... ICC = 0A to xA, where x = current at POUT = 34.5 dBm, 50 Ω load, and VCC = 3.5 V. ...
LT5514
... bandwidth extending from low frequency (LF) to 850MHz. It consists of a digitally controlled variable attenuator, followed by a high linearity amplifier. The amplifier is configured with two identical transconductance amplifiers, hard wired in parallel with individual dedicated enable pins. When bot ...
... bandwidth extending from low frequency (LF) to 850MHz. It consists of a digitally controlled variable attenuator, followed by a high linearity amplifier. The amplifier is configured with two identical transconductance amplifiers, hard wired in parallel with individual dedicated enable pins. When bot ...
Dielectric Properties at High Frequencies of Douglas Fir 20
... for both grain directions, and two curves (one for each grain (lirection) are plotted in each set on the graphs. Both dielectric constant and power factor are somewhat larger for vertical grain wood in the range of variables investigated. 6. Other variations. There are probably other differences in ...
... for both grain directions, and two curves (one for each grain (lirection) are plotted in each set on the graphs. Both dielectric constant and power factor are somewhat larger for vertical grain wood in the range of variables investigated. 6. Other variations. There are probably other differences in ...
Comanche Peak Nuclear Power Plant, Units 3 & 4 COL Application
... transmission lines. The TSPs in the ERCOT region are subject to regulations of the Public Utility Commission of Texas (PUCT) that controls new transmission facilities and needed interconnections to transmit power to and from the transmission grid. Any existing rights-of-way are utilized without comp ...
... transmission lines. The TSPs in the ERCOT region are subject to regulations of the Public Utility Commission of Texas (PUCT) that controls new transmission facilities and needed interconnections to transmit power to and from the transmission grid. Any existing rights-of-way are utilized without comp ...
Study of Transformer Resonant Overvoltages Caused by
... 3) The input impedance seen into the high-voltage winding (with open low-voltage side) is sufficiently high so that the transformer loading effect does not appreciably reduce the voltage on the high-voltage side. Note that these conditions resemble the resonant overvoltage condition described in Sec ...
... 3) The input impedance seen into the high-voltage winding (with open low-voltage side) is sufficiently high so that the transformer loading effect does not appreciably reduce the voltage on the high-voltage side. Note that these conditions resemble the resonant overvoltage condition described in Sec ...
HMC684LP4 数据资料DataSheet下载
... input IP3 performance of +32 dBm for down conversion is provided for 3G & 4G GSM/CDMA applications at an LO drive of 0 dBm. With an input 1 dB compression of +25 dBm, the RF port will accept a wide range of input signal levels. Conversion loss is 7 dB typical. The DC to 450 MHz IF frequency response ...
... input IP3 performance of +32 dBm for down conversion is provided for 3G & 4G GSM/CDMA applications at an LO drive of 0 dBm. With an input 1 dB compression of +25 dBm, the RF port will accept a wide range of input signal levels. Conversion loss is 7 dB typical. The DC to 450 MHz IF frequency response ...