IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) ISSN: 2278-1676
... Table 1. Rule Table of the Fuzzy Logic Controller ...
... Table 1. Rule Table of the Fuzzy Logic Controller ...
Power factor correction and harmonic filtering in electrical plants
... However, improving the power factor is a solution which allows technical and economic advantages; in fact, managing an installation with a low cosϕ implies an increase of costs for the power supply authority, who consequently applies a tariff structure which penalizes the withdrawal of energy with l ...
... However, improving the power factor is a solution which allows technical and economic advantages; in fact, managing an installation with a low cosϕ implies an increase of costs for the power supply authority, who consequently applies a tariff structure which penalizes the withdrawal of energy with l ...
AD8304 160 dB Range (100 pA –10 mA) Logarithmic Converter
... swing to within about 100 mV of ground (or VN) and the positive supply, VP, and provides a peak current drive capacity of ± 20 mA. The slope can be increased using the buffer and a pair of external feedback resistors. An accurate voltage reference of 2 V is also provided to facilitate the reposition ...
... swing to within about 100 mV of ground (or VN) and the positive supply, VP, and provides a peak current drive capacity of ± 20 mA. The slope can be increased using the buffer and a pair of external feedback resistors. An accurate voltage reference of 2 V is also provided to facilitate the reposition ...
OA-14 Improving Amplifier Noise for High 3rd
... 40dBm (for frequencies < 10MHz). Although not commonly considered for IF amplifiers, wideband, DC coupled operational amplifiers can offer considerable performance advantages at the lower IF (or HF) over standard AC coupled amplifiers. Particularly suitable from a distortion standpoint are a family ...
... 40dBm (for frequencies < 10MHz). Although not commonly considered for IF amplifiers, wideband, DC coupled operational amplifiers can offer considerable performance advantages at the lower IF (or HF) over standard AC coupled amplifiers. Particularly suitable from a distortion standpoint are a family ...
TrueWave AC Power Source - AMETEK Programmable Power
... The Elgar TW Series conforms to all specifications for devices as defined in IEEE 488.2, and complies with SCPI command syntax version 1995.0. ...
... The Elgar TW Series conforms to all specifications for devices as defined in IEEE 488.2, and complies with SCPI command syntax version 1995.0. ...
inverter 002 guide
... 3. Grounding the neutral will cause the inverter to shut down. Do not operate this inverter if it is wet. Do not install in the engine compartment –please install in a well-ventilated area. 4. This inverter is not tested for use with medical devices. ...
... 3. Grounding the neutral will cause the inverter to shut down. Do not operate this inverter if it is wet. Do not install in the engine compartment –please install in a well-ventilated area. 4. This inverter is not tested for use with medical devices. ...
LIEBERT CHALLENGER 3000 AIR
... The Liebert iCOM® Small Graphic Display shall be microprocessor based with a 128x64 dot matrix graphic monitor with control keys for user inputs mounted in an ergonomic, aesthetically pleasing housing. The display and housing shall be viewable while the unit panels are open or closed. All parameter ...
... The Liebert iCOM® Small Graphic Display shall be microprocessor based with a 128x64 dot matrix graphic monitor with control keys for user inputs mounted in an ergonomic, aesthetically pleasing housing. The display and housing shall be viewable while the unit panels are open or closed. All parameter ...
Catalogue 2014 1
... Traditionally incandescent lamps were only specified in terms of their power rating in Watt [W]. This was appropriate as a glowing filament always produces the same luminous flux per unit of power. This is however not the case for LED technology due to the presence of a driver circuit and the actual ...
... Traditionally incandescent lamps were only specified in terms of their power rating in Watt [W]. This was appropriate as a glowing filament always produces the same luminous flux per unit of power. This is however not the case for LED technology due to the presence of a driver circuit and the actual ...
Aalborg Universitet synchronization method
... The cut-off frequency (ωf2) of [F(s)] in (13) should be set to 2π·50/√2 rad/s in order to achieve a fast and an optimally damped decoupling of the voltage component as it has been proved in [33]-[36] for similar decoupling cells in threephase systems. The MHDC presents very fast dynamics compared to ...
... The cut-off frequency (ωf2) of [F(s)] in (13) should be set to 2π·50/√2 rad/s in order to achieve a fast and an optimally damped decoupling of the voltage component as it has been proved in [33]-[36] for similar decoupling cells in threephase systems. The MHDC presents very fast dynamics compared to ...
Comanche Peak Nuclear Power Plant, Units 3 & 4 COL Application
... transmission lines. The TSPs in the ERCOT region are subject to regulations of the Public Utility Commission of Texas (PUCT) that controls new transmission facilities and needed interconnections to transmit power to and from the transmission grid. Any existing rights-of-way are utilized without comp ...
... transmission lines. The TSPs in the ERCOT region are subject to regulations of the Public Utility Commission of Texas (PUCT) that controls new transmission facilities and needed interconnections to transmit power to and from the transmission grid. Any existing rights-of-way are utilized without comp ...
Fast digital calibration procedure for STPM01 based energy meters
... According to what pointed out above, it is possible to calibrate STPM01 based energy meters by calibration of voltage and current channels rather than of output pulse signal frequency. Since any energy measure performed by the device (active wide band and active fundamental, reactive or apparent) is ...
... According to what pointed out above, it is possible to calibrate STPM01 based energy meters by calibration of voltage and current channels rather than of output pulse signal frequency. Since any energy measure performed by the device (active wide band and active fundamental, reactive or apparent) is ...
User Manual
... The microK 100 and microK 200 thermometry bridges use a completely new ADC (analogue-to-digital converter) and low noise amplifier technology (see section 7: “The microK Technology”) to provide levels of performance previously only available using AC resistance bridges. Uniquely, the microK bridges ...
... The microK 100 and microK 200 thermometry bridges use a completely new ADC (analogue-to-digital converter) and low noise amplifier technology (see section 7: “The microK Technology”) to provide levels of performance previously only available using AC resistance bridges. Uniquely, the microK bridges ...
Towards Securing Low-Power Digital Circuits with Ultra
... show the effectiveness of the hiding performed by the system, which makes it difficult to assess in front of advanced side-channel attacks. Also, the authors do not use a real circuit load in their power/energy and area efficiency evaluations, which prevents quantifying the cost of the system relati ...
... show the effectiveness of the hiding performed by the system, which makes it difficult to assess in front of advanced side-channel attacks. Also, the authors do not use a real circuit load in their power/energy and area efficiency evaluations, which prevents quantifying the cost of the system relati ...
VOLTAGE CONTROL IN DISTRIBUTED ELECTRICITY GENERATION BY USING SYNCHRONOUS CONDENSER Mikko Mäkelä
... Offshore Generation Facilities. It also defines a common framework of obligations for Network Operators to appropriately make use of the capabilities of Power Generating Facilities’ in a transparent and non-discriminatory manner ensuring a level-playing field throughout the European Union. In this t ...
... Offshore Generation Facilities. It also defines a common framework of obligations for Network Operators to appropriately make use of the capabilities of Power Generating Facilities’ in a transparent and non-discriminatory manner ensuring a level-playing field throughout the European Union. In this t ...
M43067982
... These type of converter are controlled by the different control method as DSP, Microcontroller, and improved high efficiency buck, boost, buckboost topologies with high frequency transformer isolation. Depending upon the voltage level require at the consumer side, the ac main voltage is connected in ...
... These type of converter are controlled by the different control method as DSP, Microcontroller, and improved high efficiency buck, boost, buckboost topologies with high frequency transformer isolation. Depending upon the voltage level require at the consumer side, the ac main voltage is connected in ...