• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
9115 Multi Range DC Power Supply
9115 Multi Range DC Power Supply

How to use Noise Figure Contours T N TN 1004
How to use Noise Figure Contours T N TN 1004

... bandwidth) is set for zero output and the source resistance Rs is inserted into the circuit. The tuned amplifier is adjusted to the desired center frequency. Under these conditions the reading on the rms meter is read and recorded. The noise generator output is then increased until the rms meter rea ...
LTC2313-12 - Linear Technology
LTC2313-12 - Linear Technology

Unit 5* Resistors
Unit 5* Resistors

Unit 5 Resistors - okanagancollegefoundationrefrigeration
Unit 5 Resistors - okanagancollegefoundationrefrigeration

... • Resistors are commonly used to perform two functions in a circuit. • The second use is to produce a voltage divider. A to B = 1.5 V A to C = 7.5 V A to D = 17.5 V B to C = 6 V B to D = 16 V C to D = 10 V ...
LINECODE Object
LINECODE Object

... can easily be parsed without paying any attention to field widths. I don't believe that field widths are much of an issue with XML. The length of TEXT quantities is also not much of an issue with any modern programming languages. All three of the languages I use have a String type of indefinite leng ...
8-Bit, 250 MSPS 3.3 V A/D Converter AD9480
8-Bit, 250 MSPS 3.3 V A/D Converter AD9480

Crown MA-1200 MA-2400 Rental Manual
Crown MA-1200 MA-2400 Rental Manual

... No person has the authority to enlarge, amend, or modify this Crown Warranty. This Crown Warranty is not extended by the length of time which you are deprived of the use of the new Crown product. Repairs and replacement parts provided under the terms of this Crown Warranty shall carry only the unexp ...
2 Principles of Electrical Power Control
2 Principles of Electrical Power Control

... As long as the supply voltage is sinusoidal and symmetrical, and the load is balanced, these relations give the same correct result. If one of the abovementioned conditions is not met the obtained results will differ. The consequence of this will be that we get different values of power factors for ...
Principles of Electrical Power Control
Principles of Electrical Power Control

... As long as the supply voltage is sinusoidal and symmetrical, and the load is balanced, these relations give the same correct result. If one of the abovementioned conditions is not met the obtained results will differ. The consequence of this will be that we get different values of power factors for ...
SKY77318 数据资料DataSheet下载
SKY77318 数据资料DataSheet下载



... desired output voltage waveform from several steps of voltage, which is typically obtained from DC voltage sources. There are dierent power circuit topologies for ...
As sine wave generation by using
As sine wave generation by using

... the output waveform. To filter the waveform (Square wave, quasi sine wave or Sine wave) capacitors and inductors are used. Low pass filters, are used to reduce the harmonic components. In pulse width modulated (PWM) inverters, the input DC voltage is essentially constant in Magnitude and the AC outp ...
EEE 118-2531
EEE 118-2531

... components as separate signals Vd, Vq and V0.The active and reactive components of the system are represented by the direct and quadrature component, respectively, the decrease of the voltage flicker of the network and the compensating control to decrease the voltage flicker can be limited only base ...
lecture-7.antenna
lecture-7.antenna

STP 3 & 4 8.2  Offsite Power Systems
STP 3 & 4 8.2 Offsite Power Systems

... rights-of way for interconnects to the existing transmission grid. The description of the transmission system components for both existing and new structures as listed below fully describes and qualifies the use of this system within the present boundaries of the existing corridors. Transmission ser ...
HMMC-3104 DC-16 GHz Packaged Divide-by-4 Prescaler
HMMC-3104 DC-16 GHz Packaged Divide-by-4 Prescaler

ELECTRICAL IMPEDANCE MEASUREMENTS WITH CLIO 11
ELECTRICAL IMPEDANCE MEASUREMENTS WITH CLIO 11

BDTIC www.BDTIC.com/infineon T D A 4 8 6 3   -
BDTIC www.BDTIC.com/infineon T D A 4 8 6 3 -

Switching frequency Harmonic selection for Single Phase Multilevel
Switching frequency Harmonic selection for Single Phase Multilevel



XARTU/1™ Manual - Eagle Research Corporation
XARTU/1™ Manual - Eagle Research Corporation

... can execute multiple processes including tasks such as complex math functions, control algorithms, etc., without host intervention. Flexibility, expandability, and reliability are the major factors in the XARTU/1 design philosophy. It is a balanced system, featuring flexible memory, I/O, power, and ...
Universal Operational Amplifier Single,Dual
Universal Operational Amplifier Single,Dual

Mitigation of Unbalanced Voltage Sags and Voltage  *
Mitigation of Unbalanced Voltage Sags and Voltage *

... Sags (VS) defined by IEEE standards 1159-1995 as the reduction in the value of RMS voltage between 0.1 to 0.9 p.u at the power frequency with the duration from 0.5 cycles to 1 min represent one of the most important causes of poor power quality [1]. The main causes of voltage sags are short circuit ...
PSCAD/EMTDC Simulation of Powe
PSCAD/EMTDC Simulation of Powe

< 1 ... 32 33 34 35 36 37 38 39 40 ... 316 >

Decibel

The decibel (dB) is a logarithmic unit that expresses the ratio of two values of a physical quantity, often power or intensity. One of these quantities is often a reference value and in this case the decibel expresses the absolute level of the physical quantity. The number of decibels is ten times the logarithm to base 10 of the ratio of two power quantities, or of the ratio of the squares of two field amplitude quantities. One decibel is one tenth of one bel, named in honor of Alexander Graham Bell; however, the bel is seldom used.The definition of the decibel is based on the measurement of power in telephony of the early 20th century in the Bell System in the United States. Today, the unit is used for a wide variety of measurements in science and engineering, most prominently in acoustics, electronics, and control theory. In electronics, the gains of amplifiers, attenuation of signals, and signal-to-noise ratios are often expressed in decibels. The decibel confers a number of advantages, such as the ability to conveniently represent very large or small numbers, and the ability to carry out multiplication of ratios by simple addition and subtraction. By contrast, use of the decibel complicates operations of addition and subtraction.A change in power by a factor of 10 is a 10 dB change. At the half power point an audio circuit or an antenna exhibits an attenuation of 3dB. A change in voltage by a factor of 10 results in a change in power by a factor of 100, which is a 20 dB change. A change in voltage ratio by a factor of two approximately corresponds to a 6 dB change.The decibel symbol is often qualified with a suffix that indicates the reference quantity that has been used or some other property of the quantity being measured. For example, dBm indicates a reference power of one milliwatt, while dBu is referenced to approximately 0.775 volts RMS.In the International System of Quantities, the decibel is defined as a unit of measurement for quantities of type level or level difference, which are defined as the logarithm of the ratio of power- or field-type quantities.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report