Ingot MkII
... better than if a single capacitor was installed in their place: ESR, ripple current handling, Impedance, etc., all are improved. The reason most manufacturers do not use multiple electrolytic caps in their power supplies is plain and simple, it costs more money and takes up more space. The capacito ...
... better than if a single capacitor was installed in their place: ESR, ripple current handling, Impedance, etc., all are improved. The reason most manufacturers do not use multiple electrolytic caps in their power supplies is plain and simple, it costs more money and takes up more space. The capacito ...
infratek 108a single- to six phase power analyzer
... Standard Measure Mode In the Standard Measure Mode 280 quantities per phase are measured without gap and are continuously updated. Values can be displayed on four display pages, can be saved in internal memory, or can be transferred via Interface to a computer. The display shows voltage, current, an ...
... Standard Measure Mode In the Standard Measure Mode 280 quantities per phase are measured without gap and are continuously updated. Values can be displayed on four display pages, can be saved in internal memory, or can be transferred via Interface to a computer. The display shows voltage, current, an ...
Improvement Tolerant Control of Shunt Active Power Filter Under
... OWADAYS the increasing usage of the power electronic converters creates many problems in the electricity grid. In fact, these pollution sources absorb nonsinusoidal, and consume reactive power with generation of the harmonic currents in electric system [1]–[4]. This harmonics generation represents t ...
... OWADAYS the increasing usage of the power electronic converters creates many problems in the electricity grid. In fact, these pollution sources absorb nonsinusoidal, and consume reactive power with generation of the harmonic currents in electric system [1]–[4]. This harmonics generation represents t ...
mR1000/mR1800 Industrial Recorders
... Results of expressions using following operations can be assigned to measurement channels: Arithmetic operations, SQR (square root), ABS (absolute value), LOG (logarithm), EXP (exponent), relational operations, logical operations, totalization. (Statistical computation) Uses separate statistical com ...
... Results of expressions using following operations can be assigned to measurement channels: Arithmetic operations, SQR (square root), ABS (absolute value), LOG (logarithm), EXP (exponent), relational operations, logical operations, totalization. (Statistical computation) Uses separate statistical com ...
specification sheet for Problem 1B
... Miniature Linear Motion Series ∙ PQ12 Firgelli Technologies’ unique line of Miniature Linear Actuators enables a new generation of motion‐enabled product designs, with capabilities that have never before been combined in a device of this size. These tiny linear ac ...
... Miniature Linear Motion Series ∙ PQ12 Firgelli Technologies’ unique line of Miniature Linear Actuators enables a new generation of motion‐enabled product designs, with capabilities that have never before been combined in a device of this size. These tiny linear ac ...
Vac = 120 V rms
... As the name implies, an alternating current continually and periodically changes direction, going first one way and then reversing. One may consider an alternating current to be a DC current, which is constantly, and periodically changing amplitude and direction. The time necessary for the current t ...
... As the name implies, an alternating current continually and periodically changes direction, going first one way and then reversing. One may consider an alternating current to be a DC current, which is constantly, and periodically changing amplitude and direction. The time necessary for the current t ...
STEVAL-PSQ001V1
... The industrial standard bus is 24 V, but this voltage fluctuates and the maximum required input voltage level can be up to 36 V. Additional surge protection is also mandatory for power supply input in industrial applications. The purpose of this evaluation board is to address all of required paramet ...
... The industrial standard bus is 24 V, but this voltage fluctuates and the maximum required input voltage level can be up to 36 V. Additional surge protection is also mandatory for power supply input in industrial applications. The purpose of this evaluation board is to address all of required paramet ...
Link Budget and Fade Margin
... that this is the loss of the coaxial cable only and does not include the additional loss of any connectors used to construct a finished cable assembly. For the purposes of a link budget, the insertion loss for connectors can generally be ignored, but for the sake of completeness, an acceptable appro ...
... that this is the loss of the coaxial cable only and does not include the additional loss of any connectors used to construct a finished cable assembly. For the purposes of a link budget, the insertion loss for connectors can generally be ignored, but for the sake of completeness, an acceptable appro ...
Pedal Power MONDO
... referred to as “galvanic isolation” and means that there is no direct electrical connection between each output. Similarly, when you power your effects with batteries, they are also isolated because there is no electrical connection between the batteries. Most power supplies are not isolated. Their ...
... referred to as “galvanic isolation” and means that there is no direct electrical connection between each output. Similarly, when you power your effects with batteries, they are also isolated because there is no electrical connection between the batteries. Most power supplies are not isolated. Their ...
Direct Measurement
... catheter with pressure transducer or can be obtained using Korotkoff Sounds • Neural activity of brain, direct measurement would be implanting of electrodes or use of indirect measurement of MRI ...
... catheter with pressure transducer or can be obtained using Korotkoff Sounds • Neural activity of brain, direct measurement would be implanting of electrodes or use of indirect measurement of MRI ...
MAX2016 LF-to-2.5GHz Dual Logarithmic Detector/ Controller for Power, Gain, and VSWR Measurements
... input ports allows for the simultaneous monitoring of signals ranging from low frequency to 2.5GHz. The MAX2016 uses a pair of logarithmic amplifiers to detect and compare the power levels of two RF input signals. The device internally subtracts one power level from the other to provide a DC output ...
... input ports allows for the simultaneous monitoring of signals ranging from low frequency to 2.5GHz. The MAX2016 uses a pair of logarithmic amplifiers to detect and compare the power levels of two RF input signals. The device internally subtracts one power level from the other to provide a DC output ...
RFHA1020 数据资料DataSheet下载
... the device is saturated and uncontrolled drain current will destroy the transistor. The gate voltage must be taken to a potential lower than the source voltage to pinch off the device prior to applying the drain voltage, taking care not to exceed the gate voltage maximum limits. RFMD recommends appl ...
... the device is saturated and uncontrolled drain current will destroy the transistor. The gate voltage must be taken to a potential lower than the source voltage to pinch off the device prior to applying the drain voltage, taking care not to exceed the gate voltage maximum limits. RFMD recommends appl ...
97 E RPI MASTER
... The unit can be powered either directly from a Micro System Headset or can be connected to an external 12 Volt power supply such as the aircraft battery or a separate battery. Some specialist Lynx headsets do not contain an internal battery and must always be used with an external power supply when ...
... The unit can be powered either directly from a Micro System Headset or can be connected to an external 12 Volt power supply such as the aircraft battery or a separate battery. Some specialist Lynx headsets do not contain an internal battery and must always be used with an external power supply when ...