C-Bus Network Voltage Calculations
... Where the power supplies are spread evenly around the network, the formula can still be used. In this case, the half way point between two power supplies is like the end of a run. The voltage will be given by using the formula with half of the number of units (on the run between the two power suppli ...
... Where the power supplies are spread evenly around the network, the formula can still be used. In this case, the half way point between two power supplies is like the end of a run. The voltage will be given by using the formula with half of the number of units (on the run between the two power suppli ...
. . . Level Matching for Autosound . . . ?or Why is my system so noisy?
... Figure 3. The relationship between operating level, clipping and the noise floor. As you can see, the operating level chosen for any given device has a pretty direct effect on the working signal-to-noise ratio. Pick a level that is too high and you get premature peak clipping (but spectacular noise ...
... Figure 3. The relationship between operating level, clipping and the noise floor. As you can see, the operating level chosen for any given device has a pretty direct effect on the working signal-to-noise ratio. Pick a level that is too high and you get premature peak clipping (but spectacular noise ...
SLP 05 - Cary Audio
... IMPORTANT SAFETY INSTRUCTIONS 15. REPLACEMENT PARTS: When replacement parts are required, be sure the service technician has used replacement parts specified by the manufacturer or those having the same characteristics as the original parts. Unauthorized substitutions may result in fire, electric s ...
... IMPORTANT SAFETY INSTRUCTIONS 15. REPLACEMENT PARTS: When replacement parts are required, be sure the service technician has used replacement parts specified by the manufacturer or those having the same characteristics as the original parts. Unauthorized substitutions may result in fire, electric s ...
Diagnostic News On-Line Monitoring of Partial Discharge in Voltage Source January 2015
... quency is 40 MHz, which partly suppresses the drive switching noise. However, additional filtering with a customizable, multi‐pole filter is often needed on each capacitive coupler. A change was also needed for the TGA‐B instrument. All conventional PD instruments display the PD with resp ...
... quency is 40 MHz, which partly suppresses the drive switching noise. However, additional filtering with a customizable, multi‐pole filter is often needed on each capacitive coupler. A change was also needed for the TGA‐B instrument. All conventional PD instruments display the PD with resp ...
Guidelines on the determination of the sensitivity and calibration of
... example PE7265) and check the settings of amplifier and reference signal. 15. Increase output voltage and corresponding current Imax of a signal generator up to the value, when the voltage on the detection coil can be detected and measured. Measure this voltage Vdet on the resonance circuit at each ...
... example PE7265) and check the settings of amplifier and reference signal. 15. Increase output voltage and corresponding current Imax of a signal generator up to the value, when the voltage on the detection coil can be detected and measured. Measure this voltage Vdet on the resonance circuit at each ...
New Technologies for Reactive Power Compensation in
... by frequency converters. Thus, there are two problems to solve: Reducing harmonics to limit values that can be produced by the converters with a simultaneously high power factor, and compensating the inductive reactive power of the other consumers. Modern active power filters are able to solve both ...
... by frequency converters. Thus, there are two problems to solve: Reducing harmonics to limit values that can be produced by the converters with a simultaneously high power factor, and compensating the inductive reactive power of the other consumers. Modern active power filters are able to solve both ...
Effect of Field Plate on the RF Performance of AlGaN/GaN HEMT
... microwave applications due to their high breakdown field (3MV/cm), high electron saturation velocity (2.5×107cm2/V-s), and high operating temperature. [1] The associated AlGaN/GaN HEMT structure further features relatively high electron mobility due to the existence of the two-dimensional electron g ...
... microwave applications due to their high breakdown field (3MV/cm), high electron saturation velocity (2.5×107cm2/V-s), and high operating temperature. [1] The associated AlGaN/GaN HEMT structure further features relatively high electron mobility due to the existence of the two-dimensional electron g ...
A variable step-down conversion ratio switched capacitor DC–DC
... component. Energy is lost on the capacitor and the switch onresistances during each charge transfer to or from a capacitor. Furthermore, when the ac components in capacitor voltages are large enough, the drain voltage or source voltage of the transistors used as switches would be higher than the sup ...
... component. Energy is lost on the capacitor and the switch onresistances during each charge transfer to or from a capacitor. Furthermore, when the ac components in capacitor voltages are large enough, the drain voltage or source voltage of the transistors used as switches would be higher than the sup ...
Application Note Closed Loop Control Maximizes MAPM-030400-010C00 and MAPM-030400-060C00 Module Performance
... IV. Directional Coupler and Detector: Critical for Proper Loop Operation The directional coupler and detector are the most critical parts of the control loop system – the feedback loop can generally take care of any other variations in the components. However, any variations in the coupling factor o ...
... IV. Directional Coupler and Detector: Critical for Proper Loop Operation The directional coupler and detector are the most critical parts of the control loop system – the feedback loop can generally take care of any other variations in the components. However, any variations in the coupling factor o ...
CFL Light Dimmer
... series LC circuit with a high Q factor • Control IC sweeps the half-bridge frequency from maximum down towards the resonant frequency of the LC circuit • Lamp filaments are pre-heated as the frequency decreases and the lamp voltage and load current increase ECE 442 Power Electronics ...
... series LC circuit with a high Q factor • Control IC sweeps the half-bridge frequency from maximum down towards the resonant frequency of the LC circuit • Lamp filaments are pre-heated as the frequency decreases and the lamp voltage and load current increase ECE 442 Power Electronics ...