• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Document
Document

...  Penetration of a Wave into and through Shielding Barriers. ...
Changing Units
Changing Units

... Exercise 3. Put the quantities below into SI units to perform the requested calculation (click on the green letters for the solutions). (a) Ohm’s law V = IR links the voltage V across a resistance R to the current I flowing through it. Calculate the voltage across a 4.3 Ω (Ohm) resistor if a 4 mA (m ...
Converting units
Converting units

HMC952ALP5GE
HMC952ALP5GE

Evaluation of Magnetic Materials for Very High Frequency Power
Evaluation of Magnetic Materials for Very High Frequency Power

... inductor is equal to the capacitor current and can be calculated from the output voltage and the known capacitor impedance. (These considerations motivate the use of high-precision lowloss capacitors such as mica or porcelain capacitors. In our experiments, we have employed microwave porcelain multi ...
CMOS Micromechanical Resonator Oscillator
CMOS Micromechanical Resonator Oscillator

... Crystal oscillators are widely used to generate precision frequency standards for complex integrated circuits. With the current trend to include increasing amounts of a total system on a single silicon chip, designers have begun to include the oscillator function, sans the crystal, on the silicon di ...
Wilkinson power divider is a lossless, 100% efficient, three port
Wilkinson power divider is a lossless, 100% efficient, three port

... The quarter-wave transformers are used in the circuit since they lead to the matched ports. Matching of the output ports is necessary for better power transfer from input to output, because if the output ports are matched, the reflected power from the network when we input some amount of power is ze ...
A Novel Approach in Design of a Fuzzy Based Shunt Active Power
A Novel Approach in Design of a Fuzzy Based Shunt Active Power

Study of Quasi-Z-Source Cascaded H-Bridge Multilevel Inverter with
Study of Quasi-Z-Source Cascaded H-Bridge Multilevel Inverter with

this PDF file - Transaction Series on Engineering
this PDF file - Transaction Series on Engineering

Maurizio Delfanti - CIRED • International Conference on Electricity
Maurizio Delfanti - CIRED • International Conference on Electricity

... electricity networks and does not describe the average situation usually experienced by an individual network user. ...
[0711-000047][2016 C..
[0711-000047][2016 C..

AT-RPS3204 Redundant Power Supply Installation Guide
AT-RPS3204 Redundant Power Supply Installation Guide

Understanding Loudspeaker Power Handling Selecting the Proper
Understanding Loudspeaker Power Handling Selecting the Proper

... between increments for cooling. Power is increased in approximately 20 watt increments. The loudspeaker driver(s) along with all passive components (such as crossovers, etc.) are tested for signs of fatigue or failure between each power increment. This “power cycling” is intended to simulate real wo ...
Norstar SMDR6 Guide - NEV-comm
Norstar SMDR6 Guide - NEV-comm

Chapter 3 VOLTAGE CONTROL
Chapter 3 VOLTAGE CONTROL

5. Power supplies requirements
5. Power supplies requirements

Johnson Noise and Shot Noise Dennis V. Perepelitsa
Johnson Noise and Shot Noise Dennis V. Perepelitsa

... .74 to 1.8, so we can be reasonably sure of the three linear relations we have been attempting to demonstrate. Our error bars are noticeably high - 8% in the case of the electron charge. There are several contributors to this fact. Chief among them was the high variance present in any measurements o ...
water bath model tbs451pa operation manual
water bath model tbs451pa operation manual

... To avoid burns, DO NOT touch the bath nor water in it when the unit is operated at more than 40℃ or just after operation. Attention is also necessary when handling samples in the bath or when making up water in the bath. ...
Part B: Input and Output Impedance and Impedance Matching
Part B: Input and Output Impedance and Impedance Matching

HMC952ALP5GE
HMC952ALP5GE

On Three Phase Reactive Power
On Three Phase Reactive Power

... is generated by over-excited synchronous machines, capacitors, cables, lightly loaded overhead lines; and absorbed by under-excited synchronous machines, induction motors, inductors, transformers, heavily loaded overhead lines.”30 “There are more induction motors in regular use than any other type o ...
Design of a Three-Phase Unity Power Factor Single-Stage
Design of a Three-Phase Unity Power Factor Single-Stage

... size of the product. For this reason, major research has been carried out for the development of less complex single-stage systems which provide the same performance as their two-stage counterparts [5-9]. Most manufacturers are still looking for realization of alternative systems that improve on the ...
Aalborg Universitet Single-Phase Shunt Active Power Filters Under Adverse Grid Conditions
Aalborg Universitet Single-Phase Shunt Active Power Filters Under Adverse Grid Conditions

... by nonlinear loads. Several topologies for APFs have been proposed, with the most widely used being the shunt APFs (SAPFs) [5], [6]. As shown in Fig. 1, a SAPF is connected in parallel with the nonlinear load, and controlled to inject (draw) a compensating current, iC , to (from) the grid such that, ...
BX23450455
BX23450455

... Hence the exchange of real power and reactive power of the voltage source converter with AC system is the major required phenomenon for the regulation in the transmission as well as in the distribution system. For reactive power compensation, DSTATCOM provides reactive power as needed by the load an ...
< 1 ... 145 146 147 148 149 150 151 152 153 ... 316 >

Decibel

The decibel (dB) is a logarithmic unit that expresses the ratio of two values of a physical quantity, often power or intensity. One of these quantities is often a reference value and in this case the decibel expresses the absolute level of the physical quantity. The number of decibels is ten times the logarithm to base 10 of the ratio of two power quantities, or of the ratio of the squares of two field amplitude quantities. One decibel is one tenth of one bel, named in honor of Alexander Graham Bell; however, the bel is seldom used.The definition of the decibel is based on the measurement of power in telephony of the early 20th century in the Bell System in the United States. Today, the unit is used for a wide variety of measurements in science and engineering, most prominently in acoustics, electronics, and control theory. In electronics, the gains of amplifiers, attenuation of signals, and signal-to-noise ratios are often expressed in decibels. The decibel confers a number of advantages, such as the ability to conveniently represent very large or small numbers, and the ability to carry out multiplication of ratios by simple addition and subtraction. By contrast, use of the decibel complicates operations of addition and subtraction.A change in power by a factor of 10 is a 10 dB change. At the half power point an audio circuit or an antenna exhibits an attenuation of 3dB. A change in voltage by a factor of 10 results in a change in power by a factor of 100, which is a 20 dB change. A change in voltage ratio by a factor of two approximately corresponds to a 6 dB change.The decibel symbol is often qualified with a suffix that indicates the reference quantity that has been used or some other property of the quantity being measured. For example, dBm indicates a reference power of one milliwatt, while dBu is referenced to approximately 0.775 volts RMS.In the International System of Quantities, the decibel is defined as a unit of measurement for quantities of type level or level difference, which are defined as the logarithm of the ratio of power- or field-type quantities.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report