• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
U-120 A Simplified Approach to DC Motor
U-120 A Simplified Approach to DC Motor

is the DC-grid voltage.
is the DC-grid voltage.

The Metaphysics of Quantities and Their Dimensions˚
The Metaphysics of Quantities and Their Dimensions˚

AD6630 数据手册DataSheet 下载
AD6630 数据手册DataSheet 下载

... less than 8.5 dBm will result in damage to the clamp circuitry unless the absolute maximum input power is derated. Similarly, the output clamp level cannot be set higher than 12 dBm. ...
power and voltage rating
power and voltage rating

... Voltage, and DWV, etc. What does it all mean? Well, it is confusing since we use some of the same terms for Power calculations as for voltage calculations, but they can actually be the exact opposite of what you think they are. The main source of this problem is the RMS voltage “thing”. The followin ...
SINGLE PHASE PWM RECTIFIER IN TRACTION APPLICATION
SINGLE PHASE PWM RECTIFIER IN TRACTION APPLICATION

... reference. There have been several control schemes for an AC tracking controller such as the hysteresis control methods, the predictive control methods, and so on [2], [14]. In this work is used the resonant control approach [4], [7–10] for an AC tracking controller. The proposed control scheme usin ...
Ambiguity of the Peak Power Rating of TVS Devices
Ambiguity of the Peak Power Rating of TVS Devices

RA18H1213G <Silicon RF Power Modules > RoHS Compliance , DESCRIPTION
RA18H1213G <Silicon RF Power Modules > RoHS Compliance , DESCRIPTION

... Heat sink flatness must be less than 50 µm (a heat sink that is not flat or particles between module and heat sink may cause the ceramic substrate in the module to crack by bending forces, either immediately when driving screws or later when thermal expansion forces are added). A thermal compound be ...
EE2003 Circuit Theory
EE2003 Circuit Theory

... Note: If you express amplitude of a phasor source(s) in rms, then all the answer as a result of this phasor source(s) must also be in rms value. ...
COZIR™ Application Note: Power Consumption
COZIR™ Application Note: Power Consumption

ESS-ONE ESS-ONE Engine Sound Simulation System
ESS-ONE ESS-ONE Engine Sound Simulation System

performance in absolute perfection
performance in absolute perfection

DS507 Manual - Dyne Systems
DS507 Manual - Dyne Systems

... Dyne Systems assumes the following regarding the users of this product. • Personnel responsible for equipment use have knowledge of dynamometers, engines/ motors, instrumentation related to the testing required, and test procedures required. • Personnel responsible for electrical connections are reg ...
Auxiliary Relay
Auxiliary Relay

Zero-flux Definitions
Zero-flux Definitions

... Related to output of Zero-flux with voltage output. Overload current The maximum primary current at which the output voltage or current is still proportional with the primary current at the minimum supply voltage. At higher currents the compensating amplifier saturates, and the relation between prim ...
ISSCC 2011 slides - Massachusetts Institute of Technology
ISSCC 2011 slides - Massachusetts Institute of Technology

Active Filters
Active Filters

... increased sensitivity to variations in circuit parameters caused by environmental changes compared to passive filters ...
EVALUATING POWER FACTOR AND THD OF POWER SUPPLY
EVALUATING POWER FACTOR AND THD OF POWER SUPPLY

... sustains the electromagnetic field used to make e.g. a motor operate is an energy exchange (per unit of time) between reactive components ...
An Improved Backward/Forward Sweep Load Flow
An Improved Backward/Forward Sweep Load Flow

HIGH STEP–UP DC––DC CONVERTER FOR AC PHOTOVOLTAIC
HIGH STEP–UP DC––DC CONVERTER FOR AC PHOTOVOLTAIC

RF5385 2.4GHz TO 2.5GHz, 802.11b/g/n WiFi FRONT END MODULE Features
RF5385 2.4GHz TO 2.5GHz, 802.11b/g/n WiFi FRONT END MODULE Features

... Single Supply Voltage 3.0V to ...
HSF-1UR - Kepco power supplies
HSF-1UR - Kepco power supplies

... to be shared equally. (See Rack Adapter Manual for additional information on parallel configurations.). For current sharing to work properly the outputs of all paralleled units must be within 250 mV (max) of each other and each unit must be operating at between 10% to 100% of rated output. If curren ...
Transmission lines () - Lyle School of Engineering
Transmission lines () - Lyle School of Engineering

... • A transmission line having the following ratio of parameters: R/L=G/C, has the same loss and wave speed (phase shift or time delay) at all frequencies. It is therefore distortionless (no change in waveform shape), since all frequency components are reduced proportionately in amplitude and have the ...
MDC Foil Heater Solutions Data Sheet
MDC Foil Heater Solutions Data Sheet

... Rated  voltage  below  250V,  frequency  from  50Hz  to  60Hz,  AC  and  DC  or  dual  voltage  sources.    For  example:  with  dual   voltage,  you  get  the  same  heater  for  110  and  220  Volt  equipment.  It  incorporates ...
P85325 E560 HIFI SPEAKER SPEAKERSTROBE ROUND
P85325 E560 HIFI SPEAKER SPEAKERSTROBE ROUND

... CAUTION: Prying, turning or pivoting with screwdriver in order to remove the grille may result in damage to ceiling. ...
< 1 ... 136 137 138 139 140 141 142 143 144 ... 316 >

Decibel

The decibel (dB) is a logarithmic unit that expresses the ratio of two values of a physical quantity, often power or intensity. One of these quantities is often a reference value and in this case the decibel expresses the absolute level of the physical quantity. The number of decibels is ten times the logarithm to base 10 of the ratio of two power quantities, or of the ratio of the squares of two field amplitude quantities. One decibel is one tenth of one bel, named in honor of Alexander Graham Bell; however, the bel is seldom used.The definition of the decibel is based on the measurement of power in telephony of the early 20th century in the Bell System in the United States. Today, the unit is used for a wide variety of measurements in science and engineering, most prominently in acoustics, electronics, and control theory. In electronics, the gains of amplifiers, attenuation of signals, and signal-to-noise ratios are often expressed in decibels. The decibel confers a number of advantages, such as the ability to conveniently represent very large or small numbers, and the ability to carry out multiplication of ratios by simple addition and subtraction. By contrast, use of the decibel complicates operations of addition and subtraction.A change in power by a factor of 10 is a 10 dB change. At the half power point an audio circuit or an antenna exhibits an attenuation of 3dB. A change in voltage by a factor of 10 results in a change in power by a factor of 100, which is a 20 dB change. A change in voltage ratio by a factor of two approximately corresponds to a 6 dB change.The decibel symbol is often qualified with a suffix that indicates the reference quantity that has been used or some other property of the quantity being measured. For example, dBm indicates a reference power of one milliwatt, while dBu is referenced to approximately 0.775 volts RMS.In the International System of Quantities, the decibel is defined as a unit of measurement for quantities of type level or level difference, which are defined as the logarithm of the ratio of power- or field-type quantities.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report