• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
EE32828833
EE32828833

... reactive power to mitigate the voltage sag occurred due to different causes. Utility distribution network, sensitive industrial load and critical commercial operation suffer from various type of outage and service interruption, which can cost significant financial losses. Here, in this paper the wor ...
ECEN5817L38
ECEN5817L38

Terminator I/O Discrete Input Modules
Terminator I/O Discrete Input Modules

Unbalanced Model and Power-Flow Analysis of Microgrids and Active Distribution Systems
Unbalanced Model and Power-Flow Analysis of Microgrids and Active Distribution Systems

... • presence of non-dispatchable DG units, for example, wind and photovoltaic units [14]. Moreover, the production-grade power-flow software tools, which originally have been developed for large-system, are not and ADS analysis. The reason is that they tailored for the lack the flexibility to accommod ...
Mackie Fussion 3000 Owner`s Manual
Mackie Fussion 3000 Owner`s Manual

... There is a limit to how many you can daisy-chain together. A general rule is to maintain a load impedance 10 times or more than the source impedance to prevent excessive loading on the source. For example, if your mixer has an output impedance of 120 ohms, then you can daisy chain up to sixteen FUSS ...
Stresa, Italy, 25-27 April 2007 STEP-UP CONVERTER FOR ELECTROMAGNETIC VIBRATIONAL ENERGY SCAVENGER.
Stresa, Italy, 25-27 April 2007 STEP-UP CONVERTER FOR ELECTROMAGNETIC VIBRATIONAL ENERGY SCAVENGER.

... load resistance where the VM circuit is supplied by the vibration generators. The vibration generators are excited at their resonance frequency with the acceleration levels given in table I. The coil resistance and the resistance of the VM circuit according to equation (8) for macro generator are 46 ...
Feature Selection/Extraction for Classification Problems
Feature Selection/Extraction for Classification Problems

...  Ri  should be large Ro  should be small March, 2008 ...
- IJSRSET
- IJSRSET

... disturbances. In order to solve these problems the idea of custom power devices is introduced lately. One of those devices is the Dynamic Voltage Restorer (DVR), which is the most competent and efficient modern custom power device used in power distribution networks. Dynamic voltage restorer is also ...
AN-830 Quartz Crystal Drive Level
AN-830 Quartz Crystal Drive Level

... a resistor. Using a FET probe is also common but has disadvantages on an inverter type oscillator, like a Pierce. On an inverter type oscillator, there is phase difference between the signal at the crystal input and output which make it difficult to accurately measure the voltage across the crystal. ...
PT 12/24-60 - AltE Store
PT 12/24-60 - AltE Store

... The unit setup is easily accomplished by connecting the jumpers into the appropriate spots. Look for a label on the unit that says PXX and MXX, where XX is a number. This may mean the unit is a custom input or output and the XX represents what the unit is factory setup to run. For example, P36 M36 w ...
shielding and grounding in large detectors
shielding and grounding in large detectors

WT Series & PZ Power Analyzer WT series & PZ WT3000 WT500
WT Series & PZ Power Analyzer WT series & PZ WT3000 WT500

II3514551462
II3514551462

... The harmonic distortions in the output voltage cause the unbalanced voltage problems and decrease the efficiency of multilevel inverters. Power electronic devices contribute with important part of harmonics in all kind of applications such as power rectifiers, converters and static VAR compensators. ...
CO34543549
CO34543549

... voltage dependent load models on voltage profile and location of the SVC in power systems [7]. In case our study, each load is modeled as a stair-case dynamic load (SCDLM), in which active and reactive powers are varied at a chosen time around the base value with desired step size and realized by si ...
APPLICATION OF ARTIFICIAL NEURAL NETWORKS (ANNs)
APPLICATION OF ARTIFICIAL NEURAL NETWORKS (ANNs)

United States Court of Appeals for the Federal Circuit
United States Court of Appeals for the Federal Circuit

... disagree, for as noted above, the claims do not simply recite that the substrate voltage must be less positive than the well voltage; instead, they disclose the relative voltages of the substrate and the well by reference to the voltages of the power supplies to which they are connected. The “power ...
Fuzzy Based Control of PMBLDCM Drive with Power Quality
Fuzzy Based Control of PMBLDCM Drive with Power Quality

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... If a single-stage GCPVS is applied to a dc microgrid power distribution system, its operating voltage range of PV arrays is limited within 360–400 V. In general, an MPP voltage changes with irradiance and temperature. Therefore, Pm pp is expressed as Pm pp (Si ,T), and it is identical to (4). E. Ove ...
PowerDsine™ PoE Midspans & LED Lighting
PowerDsine™ PoE Midspans & LED Lighting

... Low voltage distribution is safer for the installer Centralized drivers can be more cost effective Lower efficiency compared to best in class mains drivers Single point of failure in central driver ...
Matlab simulations for power factor correction of switching power 8
Matlab simulations for power factor correction of switching power 8

Fundamentals of Floating Measurements and Isolated Input Oscilloscopes.pdf
Fundamentals of Floating Measurements and Isolated Input Oscilloscopes.pdf

... This guide will provide you with a fundamental glossary of power measurement terms, explain the different options available for making floating measurements, and highlight the advantages and trade-offs of each option. The most demanding floating measurement requirements are found in power control ci ...
Tektronix: Application Note > Fundamentals of Floating
Tektronix: Application Note > Fundamentals of Floating

Low-Power SoC Design Techniques
Low-Power SoC Design Techniques

... • Conventional power management optimizes power consumption when there is nothing to do (sleep modes). • IEM optimizes power when work is being done. – Only run fast enough to meet deadlines! – Running fast and idling wastes power. ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... Fuzzification 2) Fuzzy Rule-base 3) Fuzzy Inference Engine (Decision Making Logic) and 4) Defuzzification. A Fuzzy controller operates by repeating a cycle of following four steps. First, measurements are taken of all variables that represent relevant conditions of the controlled process (Universal ...
PDF
PDF

... is used for scaling in the multivariable case; it permits the assignment of more or less weight for the objective of reducing the predicted error for the output variable. A dynamic system model is used in order to forecast the controlled variables. The regulator variables variation to predict the re ...
< 1 ... 133 134 135 136 137 138 139 140 141 ... 316 >

Decibel

The decibel (dB) is a logarithmic unit that expresses the ratio of two values of a physical quantity, often power or intensity. One of these quantities is often a reference value and in this case the decibel expresses the absolute level of the physical quantity. The number of decibels is ten times the logarithm to base 10 of the ratio of two power quantities, or of the ratio of the squares of two field amplitude quantities. One decibel is one tenth of one bel, named in honor of Alexander Graham Bell; however, the bel is seldom used.The definition of the decibel is based on the measurement of power in telephony of the early 20th century in the Bell System in the United States. Today, the unit is used for a wide variety of measurements in science and engineering, most prominently in acoustics, electronics, and control theory. In electronics, the gains of amplifiers, attenuation of signals, and signal-to-noise ratios are often expressed in decibels. The decibel confers a number of advantages, such as the ability to conveniently represent very large or small numbers, and the ability to carry out multiplication of ratios by simple addition and subtraction. By contrast, use of the decibel complicates operations of addition and subtraction.A change in power by a factor of 10 is a 10 dB change. At the half power point an audio circuit or an antenna exhibits an attenuation of 3dB. A change in voltage by a factor of 10 results in a change in power by a factor of 100, which is a 20 dB change. A change in voltage ratio by a factor of two approximately corresponds to a 6 dB change.The decibel symbol is often qualified with a suffix that indicates the reference quantity that has been used or some other property of the quantity being measured. For example, dBm indicates a reference power of one milliwatt, while dBu is referenced to approximately 0.775 volts RMS.In the International System of Quantities, the decibel is defined as a unit of measurement for quantities of type level or level difference, which are defined as the logarithm of the ratio of power- or field-type quantities.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report