• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
HMC221A / 221AE - Datasheet.Live
HMC221A / 221AE - Datasheet.Live

Distributed Generation in Power System Network to Alleviate
Distributed Generation in Power System Network to Alleviate

... of a phase locked loop (PLL) and a PI controller. In this process phase angle of voltage V2 is locked. PLL techniques causes one signal to track another one. It keeps an output signal synchronized with a reference input signal in frequency and phase. In three phase grid connected system PLL can be i ...
Rubidium Frequency Standards
Rubidium Frequency Standards

Power Factor Correction and Harmonics
Power Factor Correction and Harmonics

... this is that a large current flows in the supply transformer, resulting in a large harmonic voltage distortion possibly causing equipment malfunction, loss of transformer output due to increased heating, interference with communication systems, premature failure of motors and power factor capacitors ...
How to measure output voltage from a VFD to a motor
How to measure output voltage from a VFD to a motor

Circuit Note CN-0150
Circuit Note CN-0150

... The RF signal being measured is applied to the AD8318. The device is configured in its so-called measurement mode, with the VSET and VOUT pins connected together. In this mode, the output voltage vs. the input signal level is linear-in-dB (nominally −24 mV/dB) and has a typical output voltage range ...
Solid-state NMR training course - New York Structural Biology Center
Solid-state NMR training course - New York Structural Biology Center

CHAPTER 17
CHAPTER 17

... • The full-wave rectifier is the most commonly used type in dc power supplies • allowing unidirectional current to the load during the entire input cycle differ from the half-wave rectifier that allows only during one-half of the cycle Figure 17-9 Average Value of the Full-wave rectified output volt ...
4100 Series - Magnetic Sciences
4100 Series - Magnetic Sciences

... restricted to the 50/60 Hz magnetic field emanating from power lines. ELF is an acronym similar to VHF or UHF as used for television band frequencies. ELF stands for Extremely Low Frequency and is defined as the band of frequencies from 30 to 300Hz. Although this meter will measure fields considerab ...
Document
Document

... The gear ratio (Rg) is the gear-train ratio between the rotor shaft and the fastest pointer shaft. It is the register-ratio (Rr) multiplied by the gear reduction (Rs) between the rotor shaft and the shaft of the worm gear or the gear meshing with it. The gear reduction at the shaft (Rs) is 100 for a ...
Unit 02 Ohm Laws
Unit 02 Ohm Laws

... 4. Voltage is referred to as electric pressure, potential difference, or electromotive force. An E or a V can be used to represent voltage in Ohm’s law formulas. 5. An ohm (Ω) is a measurement of resistance (R) in an electric circuit. ...
LM3886 Overture™ Audio Power Amplifier Series
LM3886 Overture™ Audio Power Amplifier Series

... Note 2: Operation is guaranteed up to 84V, however, distortion may be introduced from SPIKe Protection Circuitry if proper thermal considerations are not taken into account. Refer to the Thermal Considerations section for more information. (See SPIKe Protection Response) Note 3: DC Electrical Test; ...
P84824
P84824

... WARNING: The RSSWP strobe appliance is a FIRE ALARM DEVICE - DO NOT PAINT. WARNING: When installing strobes in an open office or other areas containing partitions or other viewing obstructions, special attention should be given to the location of the strobes so their operating effect can be seen by ...
Trajectory Sensitivities to Assess Influence of Components and
Trajectory Sensitivities to Assess Influence of Components and

Technical Requirements for Connecting Wind
Technical Requirements for Connecting Wind

... HV power systems – Basic EMC publication Directives Concerning the Protection of Telecommunication Lines Against Harmful Effects from Electric Lines, 1978 ...
Elsevier Editorial System(tm) for Integration, the VLSI Journal
Elsevier Editorial System(tm) for Integration, the VLSI Journal

Calibrating Power Meters with the Fluke 5500A Multi
Calibrating Power Meters with the Fluke 5500A Multi

... are three-terminal wattmeters. Figure 4 illustrates a simplified representation of three-terminal wattmeter connections. If you connect the 5500A calibrator to a three-terminal meter the same way you might calibrate a four-terminal meter, a number of errors can occur. If you connect the voltage sour ...
Document
Document

... Peak value The voltage or current value of a waveform at its maximum positive or negative points. Peak-to-peak The voltage or current value of a waveform value measured from its minimum to its maximum points. rms value The value of a sinusoidal voltage that indicates its heating effect, also known a ...
Metric System / Trig PowerPoint presentation
Metric System / Trig PowerPoint presentation

... • Trigonometric ratios – Relationship between an acute angle of a right triangle and the lengths of its sides • sin A = side opposite A ...
20 - COMSATS Institute of Information Technology, Virtual
20 - COMSATS Institute of Information Technology, Virtual

How can power factor correction and harmonic filtering be part of
How can power factor correction and harmonic filtering be part of

... electrical power utilization becomes a challenge, as well as a necessity to keep up with everincreasing energy demand without drastic increases in energy costs. Large industrial, commercial and institutional power users can benefit from centralized medium voltage reactive power compensation systems. ...
SSE Shunt/Static Exciter/Regulators
SSE Shunt/Static Exciter/Regulators

... elements required to maintain generator terminal voltage within ±½%. This is accomplished by monitoring the terminal voltage and comparing it to a voltage reference. Any difference developed from this comparison causes an immediate change in the dc output of the static exciter to the generator field ...
Analysis of Mode-Dependent Gain in Raman Amplified Few-Mode Fiber
Analysis of Mode-Dependent Gain in Raman Amplified Few-Mode Fiber

... Because of the strong intensity overlap between the modes, the pump power is effectively shared between the signal modes, and produce a significant power advantage [11]. In order to quantify this advantage we compare the total pump power required to amplify n/2 SMFs with the same effective area as t ...
pro mpa ii ™ user`s guide
pro mpa ii ™ user`s guide

Document
Document

... meter, etc to get maximum power. 3. Move the carriage probe in the slotted section in particular direction until there is a minimum deflection in the indicating meter is obtained note this distance as d1. 4. Once again move the carriage probe from its position d1 in particular direction in order to ...
< 1 ... 113 114 115 116 117 118 119 120 121 ... 316 >

Decibel

The decibel (dB) is a logarithmic unit that expresses the ratio of two values of a physical quantity, often power or intensity. One of these quantities is often a reference value and in this case the decibel expresses the absolute level of the physical quantity. The number of decibels is ten times the logarithm to base 10 of the ratio of two power quantities, or of the ratio of the squares of two field amplitude quantities. One decibel is one tenth of one bel, named in honor of Alexander Graham Bell; however, the bel is seldom used.The definition of the decibel is based on the measurement of power in telephony of the early 20th century in the Bell System in the United States. Today, the unit is used for a wide variety of measurements in science and engineering, most prominently in acoustics, electronics, and control theory. In electronics, the gains of amplifiers, attenuation of signals, and signal-to-noise ratios are often expressed in decibels. The decibel confers a number of advantages, such as the ability to conveniently represent very large or small numbers, and the ability to carry out multiplication of ratios by simple addition and subtraction. By contrast, use of the decibel complicates operations of addition and subtraction.A change in power by a factor of 10 is a 10 dB change. At the half power point an audio circuit or an antenna exhibits an attenuation of 3dB. A change in voltage by a factor of 10 results in a change in power by a factor of 100, which is a 20 dB change. A change in voltage ratio by a factor of two approximately corresponds to a 6 dB change.The decibel symbol is often qualified with a suffix that indicates the reference quantity that has been used or some other property of the quantity being measured. For example, dBm indicates a reference power of one milliwatt, while dBu is referenced to approximately 0.775 volts RMS.In the International System of Quantities, the decibel is defined as a unit of measurement for quantities of type level or level difference, which are defined as the logarithm of the ratio of power- or field-type quantities.
  • studyres.com © 2026