• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
ne series two-channel, network-enabled
ne series two-channel, network-enabled

... ne1600 The two-channel power amplifier shall deliver a minimum power of 450 Watts RMS per channel into 8 Ohms loads and 800 Watts RMS per channel into 4 Ohms loads with both channels operating. When switched into bridged-mono mode, the amplifier shall deliver at least 1600 Watts RMS into an 8 Ohms l ...
Wiring Main Circuit and Peripheral Devices
Wiring Main Circuit and Peripheral Devices

... ground fault detector against overloads and short-circuiting, or install a ground fault detector combined with a molded-case circuit breaker. ...
BESA_Source localization of seizure onset by phase maps
BESA_Source localization of seizure onset by phase maps

... higher frequencies or increased for lower frequencies. The interpretation of these phase maps is the same as for the voltage maps in the time domain, e.g. when clicking on spikes in an EEG. However, onset may be difficult to estimate from a cycling seizure pattern. ...
Model 330 - Lake Shore Cryotronics, Inc.
Model 330 - Lake Shore Cryotronics, Inc.

Rotor side Control of High Power Slip Ring Induction Motor using a
Rotor side Control of High Power Slip Ring Induction Motor using a

... starting is done by a shaded pole, with a turn of copper wire around part of the pole. The current induced in this turn lags behind the supply current, creating a delayed magnetic field around the shaded part of the pole face. This imparts sufficient rotational character to start the motor. These mo ...
The mercury cell problem and its solutions. (V8.5)
The mercury cell problem and its solutions. (V8.5)

... For cameras like the Rollei 35’s these solutions are not a good option because the (half full?) film must be taken out of the camera to change the batteries. There are ‘replacements’ for the PX625, the ‘Wein’ MRB625 and ‘Rittz’ MX625. Regrettably these cells are expensive compared to 675-hearing aid ...
RX610, RX62N, RX621 Group
RX610, RX62N, RX621 Group

... Once the MCU has switched from the main clock oscillator (MCO) to the on-chip oscillator (OCOCLK), it continues to run on OCOCLK even if MCO is re-established; a reset of the MCU is required to switch back to the main clock oscillator. The Oscillation Stop Detection circuit is enabled by default aft ...
TPS22918-Q1 5.5-V, 2-A, 52-mΩ On-Resistance
TPS22918-Q1 5.5-V, 2-A, 52-mΩ On-Resistance

... Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absol ...
Comprehensive Modulation and Classification of Faults and
Comprehensive Modulation and Classification of Faults and

... connected to grid. Internal maximums point power tracker algorithm with some method must be applied for rising efficiency of the system. In AC side of PV system, typically two types of faults could be happened: total black out which considered as exterior fault for system, lighting and unbalanced vo ...
376B Series
376B Series

... be set from 0.00001 to 9.99999. The 376B also allows setting of the decimal point position in any of 6 positions. RESETTING THE COUNTER: The Counter can be reset using the Reset key on the panel or by using the external Reset Inputs. There are three current sinking external inputs. Each one is dedic ...
Locating RF Interference at HF
Locating RF Interference at HF

... received frequency. Since the NE602 has a conversion gain of about 20 dB the total gain is about 100 dB. The input impedance of the NE602 is 1500 Ω so I used a broadband transformer with a 5:1 turns ratio to match a 50 Ω input. An emitter follower drives a pair of low-impedance headphones. Also, the ...
Exam 1
Exam 1

... ____ 21. Which has a bigger resistance, a hair dryer (1000 W) or a light bulb (100 W)? a. both the same c. hair dryer b. light bulb d. not enough info to tell ____ 22. Consider this circuit. What is the current through the resistor? ...
PCA9703 1. General description 18 V tolerant SPI 16-bit GPI with maskable INT
PCA9703 1. General description 18 V tolerant SPI 16-bit GPI with maskable INT

... HIGH. This also enables the interrupt output, which will only indicate an interrupt if the GPI data does not match the input status register on a bit that is enabled by the interrupt mask register value. If an interrupt is generated, the pull-up or pull-down source should remain active and the INT_E ...
DELTA reflex Motion Detectors, IP55
DELTA reflex Motion Detectors, IP55

... A key feature of the DELTA reflex motion detector IP55 is the precision with which its values can be preset compared to standard motion detectors, which are set over potentiometers. So there is no need to go back and adjust the devices. Convenient mounting: quick and easy wiring in the terminal box. ...
Task A. Transmission Line and Discontinuities
Task A. Transmission Line and Discontinuities

... with the strip electrode having zero thickness and the dielectric being free space everywhere. This problem can be solved exactly by the method of conformal mapping, but the expressions are very complex and more useful results are the various approximations to the exact expressions. A particularly u ...
Generator Stator Protection, under/over voltage, under /over
Generator Stator Protection, under/over voltage, under /over

Kosky, Wise, Balmer, Keat: Exploring Engineering, Second Edition
Kosky, Wise, Balmer, Keat: Exploring Engineering, Second Edition

... Then across either of the 1,000 Ω resistors, (V – 0) = ½ I × 1.0 × 103. These are two equations in two unknowns and solving by eliminating V gives 12 = I × (1.0 × 102 + ½ × 1.0 × 103) ∴ I = 12/(1.0 × 102 + ½ × 1.0 × 103) [V][A/V] = 0.020 A (Incidentally if you also needed V it is 10. volts. This is ...
Chapter 11 Shielded Metal Arc Welding Principles
Chapter 11 Shielded Metal Arc Welding Principles

... • Percentage of any given 10-minute period that machine can operate at rated current without overheating or breaking down – Rating of 100% means machine can be used at rated amperage on continuous basis • Required by continuous, automatic machine welding ...
Frequency combs and frequency dissemination for scientific and
Frequency combs and frequency dissemination for scientific and

... experiments on laser cooling. For both experiments only one laser and one stabilisation unit are necessary owing to the highly precise dissemination method. The required frequency stability is realised by the control of a frequency comb. This stabilisation method can be adapted to any arbitrary appl ...
Passive cable properties of hippocampal CA3 pyramidal neurons
Passive cable properties of hippocampal CA3 pyramidal neurons

2005 Code Changes
2005 Code Changes

... current rating. This facilitates the inspection and approval process. Inspectors need this information to ensure that 110.10 is met. The potential hazard exists where higher fault currents are available. It is now required that industrial control panels, industrial machinery electrical panels, certa ...
Analysis and Design of Quasi- Square Wave Resonant Converters
Analysis and Design of Quasi- Square Wave Resonant Converters

Section B - theonlineteachers
Section B - theonlineteachers

... This paper consists of 12 printed pages. Candidates should check the question paper to ensure that all pages are printed as indicated and no questions are missing. © 2016 Rarieda Sub-county mock ...
Post NAND Flash Approaches - How does Schiltron Compare?
Post NAND Flash Approaches - How does Schiltron Compare?

... No difference between best case and worst case string currents with both being larger than other TFT SONOS NAND approaches; ...
Chapter 2 Circuit Elements
Chapter 2 Circuit Elements

... ammeter and the reference direction of the measured current. In (b) the current ia is directed to the right, while in (c) the current ib is directed to the left. The colored probe is shown here in blue. In the laboratory this probe will be red. We will refer to the colored probe as the “red probe”. ...
< 1 ... 400 401 402 403 404 405 406 407 408 ... 2982 >

Opto-isolator



In electronics, an opto-isolator, also called an optocoupler, photocoupler, or optical isolator, is a component that transfers electrical signals between two isolated circuits by using light. Opto-isolators prevent high voltages from affecting the system receiving the signal. Commercially available opto-isolators withstand input-to-output voltages up to 10 kV and voltage transients with speeds up to 10 kV/μs.A common type of opto-isolator consists of an LED and a phototransistor in the same opaque package. Other types of source-sensor combinations include LED-photodiode, LED-LASCR, and lamp-photoresistor pairs. Usually opto-isolators transfer digital (on-off) signals, but some techniques allow them to be used with analog signals.