expCpid_EDIT
... The DC Power Supply is used to create step input response to the controller. The input values are changed to create different DC levels that simulate a step change. Set the Current knob to minimum and the current selector to ‘LO’ Adjust the voltage knob ‘FINE’ centre position. Change the voltage out ...
... The DC Power Supply is used to create step input response to the controller. The input values are changed to create different DC levels that simulate a step change. Set the Current knob to minimum and the current selector to ‘LO’ Adjust the voltage knob ‘FINE’ centre position. Change the voltage out ...
GCK-01 Geiger Counter Kit Manual and Assembly Guide
... How Much Radiation is Safe? In the United States the U.S. Nuclear Regulatory Commission (NRC) determines what radiation exposure level is considered safe. Occupational exposure for worker is limited to 5000 mrem per year. For the general population, the exposure is 500 mrem above background radiatio ...
... How Much Radiation is Safe? In the United States the U.S. Nuclear Regulatory Commission (NRC) determines what radiation exposure level is considered safe. Occupational exposure for worker is limited to 5000 mrem per year. For the general population, the exposure is 500 mrem above background radiatio ...
full text)
... quantum bits and eventually as quantum computers. A quantum bit can be any two-state quantum system that maintains quantum coherence for long enough to perform practical quantum operations. To make a quantum computer, these quantum bits must be controllable and measurable. In superconducting systems ...
... quantum bits and eventually as quantum computers. A quantum bit can be any two-state quantum system that maintains quantum coherence for long enough to perform practical quantum operations. To make a quantum computer, these quantum bits must be controllable and measurable. In superconducting systems ...
PDF
... form of the voltage supply. It is permissible to represent the distorting equipment as a source of harmonic current that are independent of the impedance of the supplying of the system. The effect of superposing a number of sources on a system can then be found by representing each of them by an equ ...
... form of the voltage supply. It is permissible to represent the distorting equipment as a source of harmonic current that are independent of the impedance of the supplying of the system. The effect of superposing a number of sources on a system can then be found by representing each of them by an equ ...
G201 INSTALLATION NOTES:
... The internal fuse is the G213V‟s final line of protection. It blows only under the most extreme circumstances. Those are reversed power supply polarity; AC voltage instead of DC voltage on terminals 1 and 2 and power supply voltages in excess of 114VDC. Correct the problem and replace the fuse with ...
... The internal fuse is the G213V‟s final line of protection. It blows only under the most extreme circumstances. Those are reversed power supply polarity; AC voltage instead of DC voltage on terminals 1 and 2 and power supply voltages in excess of 114VDC. Correct the problem and replace the fuse with ...
AD8342 数据手册DataSheet 下载
... Differential IF Outputs (Open Collectors). Each requires dc bias of 5.00 V (nominal). Mixer Bias Voltage. Connect resistor from EXRB to ground. Typical value of 1.82 kΩ sets mixer current to nominal value. Minimum resistor value from EXRB to ground = 1.8 kΩ. Internally biased to 1.17 V. Connect to G ...
... Differential IF Outputs (Open Collectors). Each requires dc bias of 5.00 V (nominal). Mixer Bias Voltage. Connect resistor from EXRB to ground. Typical value of 1.82 kΩ sets mixer current to nominal value. Minimum resistor value from EXRB to ground = 1.8 kΩ. Internally biased to 1.17 V. Connect to G ...
EE2251-Electrical Machines I
... When emf induced in a conductor is stationary in a magnetic field then we call it statically induced emf. If emf is induced in a conductor due to relative motion between conductor and the field then it call it as dynamically induced emf. 3. What does speed voltage mean? It is that voltage generated ...
... When emf induced in a conductor is stationary in a magnetic field then we call it statically induced emf. If emf is induced in a conductor due to relative motion between conductor and the field then it call it as dynamically induced emf. 3. What does speed voltage mean? It is that voltage generated ...
$doc.title
... Electrical circuits connect power supplies to loads such as resistors, capacitors, motors, heaters, or lamps. The connection between the supply and the load is made by soldering with wires that are often called leads, or with many kinds of connectors and terminals. Energy is delivered from the sourc ...
... Electrical circuits connect power supplies to loads such as resistors, capacitors, motors, heaters, or lamps. The connection between the supply and the load is made by soldering with wires that are often called leads, or with many kinds of connectors and terminals. Energy is delivered from the sourc ...
General Description Features
... Note that adding this pull-up resistor to the MAX6330 will render RESET invalid with VSHUNT < 1V, since this output loses sinking capability at this point, and the pull-up resistor would invalidate the signal. This does not present a problem in most applications, since most µPs and other circuitry a ...
... Note that adding this pull-up resistor to the MAX6330 will render RESET invalid with VSHUNT < 1V, since this output loses sinking capability at this point, and the pull-up resistor would invalidate the signal. This does not present a problem in most applications, since most µPs and other circuitry a ...
fulltext
... joining metals. It has extensive applications in household appliances and in automotive industries. The traditional approach in relation to spot welding machines is to use 50 Hz welding transformers. The drawback associated with these transformers is that they are both heavy and bulky. Moreover, the ...
... joining metals. It has extensive applications in household appliances and in automotive industries. The traditional approach in relation to spot welding machines is to use 50 Hz welding transformers. The drawback associated with these transformers is that they are both heavy and bulky. Moreover, the ...
ESD Pitfalls of Third Party IP
... Independent Lab reports for HBM, MM, CDM results. Transmission line pulse I/V for ESD clamps ESD parameters extracted from TLP measurements for wafer foundry processes Latchup current values for different I/O types over temperature ...
... Independent Lab reports for HBM, MM, CDM results. Transmission line pulse I/V for ESD clamps ESD parameters extracted from TLP measurements for wafer foundry processes Latchup current values for different I/O types over temperature ...
PLUS+1® SC0XX-1XX Controller Family Safety Manual
... dangerous, both detected and undetected. In IEC 61508, the No Effect failures cannot contribute to the failure rate of the safety function. Therefore, they are not used for the Safe Failure Fraction calculation. (2) Depending on the application, a Fail High or a Fail Low failure can either be safe o ...
... dangerous, both detected and undetected. In IEC 61508, the No Effect failures cannot contribute to the failure rate of the safety function. Therefore, they are not used for the Safe Failure Fraction calculation. (2) Depending on the application, a Fail High or a Fail Low failure can either be safe o ...
Arduino Lesson 13. DC Motors
... You could type any number here, so the 'if' statement on the next line only does an analog write with this number if the number is between 0 and 255. ...
... You could type any number here, so the 'if' statement on the next line only does an analog write with this number if the number is between 0 and 255. ...
Quadrature Demodulator with IF PLL/VCO
... large capacitor is an alternative but may require more board space and so may not be preferred. The supply decoupling shown is intended for RF noise suppression. It is necessary to have a small series impedance prior to the decoupling capacitor for the decoupling to work well. This may be achieved c ...
... large capacitor is an alternative but may require more board space and so may not be preferred. The supply decoupling shown is intended for RF noise suppression. It is necessary to have a small series impedance prior to the decoupling capacitor for the decoupling to work well. This may be achieved c ...
600 Volt Automatic Transfer Switches
... outages so that contact pressure is maintained at a constant value and temperature rise at the contacts is minimized for maximum reliability and operating life. D. The switch shall be mechanically interlocked to ensure only one of two possible positions normal or emergency for single solenoid design ...
... outages so that contact pressure is maintained at a constant value and temperature rise at the contacts is minimized for maximum reliability and operating life. D. The switch shall be mechanically interlocked to ensure only one of two possible positions normal or emergency for single solenoid design ...
A DC Motor Controller Using The ZILOG Z86E06 MCU Application
... respectively, to the LMD18200. The current sensing is done with a resistor to ground from pin 8 of the LMD18200. The current output from this pin is typically 377 µA/per A. If the motor is rated at 1A, a resistor value is chosen so that the voltage developed across the resistor does not exceed 4V, w ...
... respectively, to the LMD18200. The current sensing is done with a resistor to ground from pin 8 of the LMD18200. The current output from this pin is typically 377 µA/per A. If the motor is rated at 1A, a resistor value is chosen so that the voltage developed across the resistor does not exceed 4V, w ...
Technical Description PCM Modules ZM modular
... The pulse code module can convert these signals directly into 230 V quasi sine half-wave combinations, since these signals run synchronized to the mains voltage, and feed them to the trolley controllers over the control rails (S1). Every pulse code command is detected depending to the software by th ...
... The pulse code module can convert these signals directly into 230 V quasi sine half-wave combinations, since these signals run synchronized to the mains voltage, and feed them to the trolley controllers over the control rails (S1). Every pulse code command is detected depending to the software by th ...
Error Probability for M Signals
... In this chapter we discuss the error probability in deciding which of M signals was transmitted over an arbitrary channel. We assume the signals are represented by a set of N orthonormal functions. Writing down an expression for the error probability in terms of an N-dimensional integral is straight ...
... In this chapter we discuss the error probability in deciding which of M signals was transmitted over an arbitrary channel. We assume the signals are represented by a set of N orthonormal functions. Writing down an expression for the error probability in terms of an N-dimensional integral is straight ...
Opto-isolator
In electronics, an opto-isolator, also called an optocoupler, photocoupler, or optical isolator, is a component that transfers electrical signals between two isolated circuits by using light. Opto-isolators prevent high voltages from affecting the system receiving the signal. Commercially available opto-isolators withstand input-to-output voltages up to 10 kV and voltage transients with speeds up to 10 kV/μs.A common type of opto-isolator consists of an LED and a phototransistor in the same opaque package. Other types of source-sensor combinations include LED-photodiode, LED-LASCR, and lamp-photoresistor pairs. Usually opto-isolators transfer digital (on-off) signals, but some techniques allow them to be used with analog signals.