Buck Converter: Negative Spike at Phase Node
... Lstray is the total value of the critical loop inductance consisting of L1 and L2. L2 is the part of Lstray that is located in the synchronous rectification path, i.e. between GND and phase node. L1 is the part of the L stray that is not part of L2. Another assumption is that the HS-MOSFET is switch ...
... Lstray is the total value of the critical loop inductance consisting of L1 and L2. L2 is the part of Lstray that is located in the synchronous rectification path, i.e. between GND and phase node. L1 is the part of the L stray that is not part of L2. Another assumption is that the HS-MOSFET is switch ...
Sedona Series D (2010)
... Connect this cable directly to the frame of the vehicle. Make sure the metal frame has been stripped of all paint down to the bare metal. Use the shortest distance possible. It is always a good idea to replace the factory ground at this time with a larger cable equal to the new amplifier power cable ...
... Connect this cable directly to the frame of the vehicle. Make sure the metal frame has been stripped of all paint down to the bare metal. Use the shortest distance possible. It is always a good idea to replace the factory ground at this time with a larger cable equal to the new amplifier power cable ...
RF2173 - RFMD.com
... +3dBm. Based upon HBT (Heterojunction Bipolar Transistor) technology, the part requires only a single positive 3V supply to operate to full specification. Power control is provided through a single pin interface, with a separate Power Down control pin. The final stage ground is achieved through the ...
... +3dBm. Based upon HBT (Heterojunction Bipolar Transistor) technology, the part requires only a single positive 3V supply to operate to full specification. Power control is provided through a single pin interface, with a separate Power Down control pin. The final stage ground is achieved through the ...
CMS2005 - Sensitec GmbH
... This sensor shall be used in electric and electronic devices according to applicable standards and safety requirements. Sensitec’s datasheet and handling instructions must be complied with. Handling instructions for current sensors are available at www.sensitec.com. Caution! Risk of electric shock! ...
... This sensor shall be used in electric and electronic devices according to applicable standards and safety requirements. Sensitec’s datasheet and handling instructions must be complied with. Handling instructions for current sensors are available at www.sensitec.com. Caution! Risk of electric shock! ...
Electrocardiogram Analysis
... 1. Mail carrier puts mail in the box, then lifts up the flag. The flag is attached to a lever that sets a lock as it is raised. 2. Later in the day, the resident comes to pick up mail. He / she enters a code on a keypad which disengages the lock. He / she opens the door, gets the mail, pulls down th ...
... 1. Mail carrier puts mail in the box, then lifts up the flag. The flag is attached to a lever that sets a lock as it is raised. 2. Later in the day, the resident comes to pick up mail. He / she enters a code on a keypad which disengages the lock. He / she opens the door, gets the mail, pulls down th ...
HMC594LC3B
... *Adjust Vgg between -1.5V to -0.5V to achieve Idd = 100mA typical for 6V or Idd = 95mA typical for 5V. ...
... *Adjust Vgg between -1.5V to -0.5V to achieve Idd = 100mA typical for 6V or Idd = 95mA typical for 5V. ...
MMPQ6700 Quad NPN & PNP General Purpose Amplifier
... support device or system whose failure to perform can systems which, (a) are intended for surgical implant into be reasonably expected to cause the failure of the life the body, or (b) support or sustain life, or (c) whose support device or system, or to affect its safety or failure to perform when ...
... support device or system whose failure to perform can systems which, (a) are intended for surgical implant into be reasonably expected to cause the failure of the life the body, or (b) support or sustain life, or (c) whose support device or system, or to affect its safety or failure to perform when ...
Electrostatics, Electric Fields, and Electric Potential
... P = IV = I2R. Electric power is transported at high V and low I to minimize “I2R loss” (high I causes too much friction and heat). ...
... P = IV = I2R. Electric power is transported at high V and low I to minimize “I2R loss” (high I causes too much friction and heat). ...
2016 China International Conference on Electricity Distribution
... environmental conditions, the VM of PV array is approximately proportional to change when the Voc of PV array change. Approximate linear relationship exists between Vm and Voc, namely VM≈k1×Voc, in this paper k1=0.78*Voc is affected by illumination change slightly and is influenced by the temperatur ...
... environmental conditions, the VM of PV array is approximately proportional to change when the Voc of PV array change. Approximate linear relationship exists between Vm and Voc, namely VM≈k1×Voc, in this paper k1=0.78*Voc is affected by illumination change slightly and is influenced by the temperatur ...
LV UltraMOV™ Low Voltage, High Surge Current Varistor
... 12VDC–48VDC circuits are used in a variety of applications, including telecom power, sensing, automation, control, and security systems. Transients on these lines can be caused by lightning interference, inductive spikes from power switching, and fast transients from induced power line fluctuations. ...
... 12VDC–48VDC circuits are used in a variety of applications, including telecom power, sensing, automation, control, and security systems. Transients on these lines can be caused by lightning interference, inductive spikes from power switching, and fast transients from induced power line fluctuations. ...
12A High Efficiency Synchronous Point of Load Buck Regulator with
... Feedback pin is connected to the inverting input of the voltage loop error amplifier. Quiet analog ground for the internal reference and bias circuitry. Exposed metal pad on the underside of the package with an electrical and thermal connection to PGND. It is recommended to connect this pad to the P ...
... Feedback pin is connected to the inverting input of the voltage loop error amplifier. Quiet analog ground for the internal reference and bias circuitry. Exposed metal pad on the underside of the package with an electrical and thermal connection to PGND. It is recommended to connect this pad to the P ...
PICAXE DATALOGGER (AXE110P)
... CT7. The negative (black) wire should be connected to GND. When connecting the wires it is recommended that the bare wire is bent back over the insulation, and then the screw tightened on both. This gives a much stronger joint. If a wall-plug adapter is used it must be a very high quality regulated ...
... CT7. The negative (black) wire should be connected to GND. When connecting the wires it is recommended that the bare wire is bent back over the insulation, and then the screw tightened on both. This gives a much stronger joint. If a wall-plug adapter is used it must be a very high quality regulated ...
AD7414
... Initialization with Operating Temperature Threshold Value Eliminates the Need for Extensive System Thermal Evaluation to Determine Tmin Value Optimizes the Control Loop to Keep Fans Running at the Lowest Possible Speed Irrespective of Thermal Changes Due to System Configuration or Operating Co ...
... Initialization with Operating Temperature Threshold Value Eliminates the Need for Extensive System Thermal Evaluation to Determine Tmin Value Optimizes the Control Loop to Keep Fans Running at the Lowest Possible Speed Irrespective of Thermal Changes Due to System Configuration or Operating Co ...
Power Flow Control by Use of Phase
... Usually transformers are used to transport electric power between different voltage levels of the electric grid. Transformers may also be used to phase angle control between the primary (source) and the secondary (load) side. Such special transformers are termed phaseshifting transformers (phase ang ...
... Usually transformers are used to transport electric power between different voltage levels of the electric grid. Transformers may also be used to phase angle control between the primary (source) and the secondary (load) side. Such special transformers are termed phaseshifting transformers (phase ang ...
Current Sensing in Pass Transistor
... In all cases the resistive network at the input of the proposed sense amplifiers correspond to the resistances of the pass transistor stack. The root node of the tree is grounded and the two outputs, S+ and S- are connected to the two inputs of the sense amplifier. Each branch of the sense amplifier ...
... In all cases the resistive network at the input of the proposed sense amplifiers correspond to the resistances of the pass transistor stack. The root node of the tree is grounded and the two outputs, S+ and S- are connected to the two inputs of the sense amplifier. Each branch of the sense amplifier ...
MAX9618 Evaluation Kit Evaluates: General Description Features
... The MAX9618 EV kit provides a proven layout for the MAX9618 low-power, zero-drift dual operational amplifier (op amp). The MAX9618 is a single-supply dual op amp (op-amp A and op-amp B) that is ideal for buffering low-frequency sensor signals. The Sallen-Key topology is easily accomplished by changi ...
... The MAX9618 EV kit provides a proven layout for the MAX9618 low-power, zero-drift dual operational amplifier (op amp). The MAX9618 is a single-supply dual op amp (op-amp A and op-amp B) that is ideal for buffering low-frequency sensor signals. The Sallen-Key topology is easily accomplished by changi ...
MAX3803 Evaluation Kit ________________ General Description Features _________________________
... VTI and VTO, respectively. Care must be taken to ensure that no direct short exists between the supply voltage and supply ground. Normal dccoupled operation with all positive supplies causes permanent damage to laboratory test equipment because a dc path exists from the power supply to the ports of ...
... VTI and VTO, respectively. Care must be taken to ensure that no direct short exists between the supply voltage and supply ground. Normal dccoupled operation with all positive supplies causes permanent damage to laboratory test equipment because a dc path exists from the power supply to the ports of ...
74LCX16373 Low Voltage 16-Bit Transparent Latch with 5V
... its I input changes. When LEn is LOW, the latches store information that was present on the I inputs a setup time preceding the HIGH-to-LOW transition of LEn. The 3-STATE standard outputs are controlled by the Output Enable (OEn) input. When OEn is LOW, the standard outputs are in the 2-state mode. ...
... its I input changes. When LEn is LOW, the latches store information that was present on the I inputs a setup time preceding the HIGH-to-LOW transition of LEn. The 3-STATE standard outputs are controlled by the Output Enable (OEn) input. When OEn is LOW, the standard outputs are in the 2-state mode. ...
Opto-isolator
In electronics, an opto-isolator, also called an optocoupler, photocoupler, or optical isolator, is a component that transfers electrical signals between two isolated circuits by using light. Opto-isolators prevent high voltages from affecting the system receiving the signal. Commercially available opto-isolators withstand input-to-output voltages up to 10 kV and voltage transients with speeds up to 10 kV/μs.A common type of opto-isolator consists of an LED and a phototransistor in the same opaque package. Other types of source-sensor combinations include LED-photodiode, LED-LASCR, and lamp-photoresistor pairs. Usually opto-isolators transfer digital (on-off) signals, but some techniques allow them to be used with analog signals.