BDX53/A/B/C NPN Epitaxial Silicon Transistor BDX53/A/B/C — NP N Epit
... cause the failure of the life support device or system, or to affect its accordance with instructions for use provided in the labeling, can be safety or effectiveness. reasonably expected to result in a significant injury of the user. ANTI-COUNTERFEITING POLICY Fairchild Semiconductor Corporation's ...
... cause the failure of the life support device or system, or to affect its accordance with instructions for use provided in the labeling, can be safety or effectiveness. reasonably expected to result in a significant injury of the user. ANTI-COUNTERFEITING POLICY Fairchild Semiconductor Corporation's ...
PQI Guide Spec 26 2200
... Product Data: Submit the following information for review and approval by the engineer of record prior to delivery and installation of each transformer that is to be supplied for this ...
... Product Data: Submit the following information for review and approval by the engineer of record prior to delivery and installation of each transformer that is to be supplied for this ...
affolder-serialpower
... Shunt-LDO regulators can be placed in parallel without problems regarding mismatch & shunt current distribution Shunt-LDO having different output voltages can be placed in parallel Shunt-LDO can cope with an increased supply current if one FE-I4 does not contribute to the regulation Failed regulator ...
... Shunt-LDO regulators can be placed in parallel without problems regarding mismatch & shunt current distribution Shunt-LDO having different output voltages can be placed in parallel Shunt-LDO can cope with an increased supply current if one FE-I4 does not contribute to the regulation Failed regulator ...
ISL90460 - Intersil
... There are two sections of the ISL90460: the input control, counter and decode section; and the resistor array. The input control section operates just like an up/down counter. The output of this counter is decoded to turn on a single electronic switch connecting a point on the resistor array to the ...
... There are two sections of the ISL90460: the input control, counter and decode section; and the resistor array. The input control section operates just like an up/down counter. The output of this counter is decoded to turn on a single electronic switch connecting a point on the resistor array to the ...
download
... distances between locations of less than 13,000 feet) B = Multi-mode 8 port switch (Reccommended for distances between locations of less than 13,000 feet and more than one Touchscreen/Monitor is in the vault)) C = Single-mode 5 port switch (Reccommended for distances between locations of greater tha ...
... distances between locations of less than 13,000 feet) B = Multi-mode 8 port switch (Reccommended for distances between locations of less than 13,000 feet and more than one Touchscreen/Monitor is in the vault)) C = Single-mode 5 port switch (Reccommended for distances between locations of greater tha ...
PHET circuit simulation
... Introduction: Wouldn’t it be great to see inside wires and electrical devices, to actually watch the electrons flow? This simulation allows us to do this. In this sim, you will build simple and compound circuits and measure their potential (voltage), current, and resistance. Additionally, you will v ...
... Introduction: Wouldn’t it be great to see inside wires and electrical devices, to actually watch the electrons flow? This simulation allows us to do this. In this sim, you will build simple and compound circuits and measure their potential (voltage), current, and resistance. Additionally, you will v ...
Applications of Variable Speed Drives
... with different components. For the same output flow, the inefficient system absorbs more than twice the power absorbed by the optimized system, showing the importance of integrated motor systems design. B. Staged Pumping Plants In many pumping applications several pumps are used in parallel to produ ...
... with different components. For the same output flow, the inefficient system absorbs more than twice the power absorbed by the optimized system, showing the importance of integrated motor systems design. B. Staged Pumping Plants In many pumping applications several pumps are used in parallel to produ ...
Low ESR capacitors - NIC Components Corp.
... tantalum becomes less available and human rights issues are raised about some of its African sources. Estimates, niobium is over 100 times more plentiful than tantalum (less than 1/10th the cost). NIC’s NBP series has same construction as conductive polymer cathode tantalum (NIC NTP Series). It is a ...
... tantalum becomes less available and human rights issues are raised about some of its African sources. Estimates, niobium is over 100 times more plentiful than tantalum (less than 1/10th the cost). NIC’s NBP series has same construction as conductive polymer cathode tantalum (NIC NTP Series). It is a ...
Varistors MLA Datasheet
... (EMC). The MLA Series is typically applied to protect integrated circuits and other components at the circuit board level. The wide operating voltage and energy range make the MLA Series suitable for numerous applications on power supply, control and signal lines. ...
... (EMC). The MLA Series is typically applied to protect integrated circuits and other components at the circuit board level. The wide operating voltage and energy range make the MLA Series suitable for numerous applications on power supply, control and signal lines. ...
Analysis of the Occurrence of a Three-Phase Short-Circuit
... electrical power utility of the State of Minas Gerais, with an installed capacity of 5514MW and an extra-high voltage transmission system comprising 30 substations and 4817 km of transmission lines at voltages ranging from 230kV to 500 kV. CEMIG supplies electricity to 96% of the State of Minas Gera ...
... electrical power utility of the State of Minas Gerais, with an installed capacity of 5514MW and an extra-high voltage transmission system comprising 30 substations and 4817 km of transmission lines at voltages ranging from 230kV to 500 kV. CEMIG supplies electricity to 96% of the State of Minas Gera ...
Products for marine applications Performance and reliability in
... The PCS 6000 OPS frequency converters are an economic and efficient solution for converting grid electricity to the appropriate frequency needed onboard, thereby allowing ships to be connected to the public grid. The majority of ships operate with a 60 Hz supply while the local grid in many parts of ...
... The PCS 6000 OPS frequency converters are an economic and efficient solution for converting grid electricity to the appropriate frequency needed onboard, thereby allowing ships to be connected to the public grid. The majority of ships operate with a 60 Hz supply while the local grid in many parts of ...
ADC, FFT and Noise. p. 1 ADC, FFT, and Noise
... (1) Show that noise cannot be absolutely white by showing that if the spectral density is constant over an infinite frequency range then the total power is infinite. (2) Examine your noise power spectrum using the LabView program supplied. Extend your measurements to the highest frequencies permitte ...
... (1) Show that noise cannot be absolutely white by showing that if the spectral density is constant over an infinite frequency range then the total power is infinite. (2) Examine your noise power spectrum using the LabView program supplied. Extend your measurements to the highest frequencies permitte ...
Solid-state Timer - OMRON Industrial Automation
... Minimum applied load: 10mA at 5 VDC (failure level: P reference value) Contact materials: Ag-alloy H3CR-A8E 5A at 250 VAC/30 VDC, 0.15A at 125 VDC, resistive load (cosφ = 1) Minimum applied load: 10mA at 5 VDC (failure level: P reference value) Contact materials: AgSnIn • Transistor output: Open col ...
... Minimum applied load: 10mA at 5 VDC (failure level: P reference value) Contact materials: Ag-alloy H3CR-A8E 5A at 250 VAC/30 VDC, 0.15A at 125 VDC, resistive load (cosφ = 1) Minimum applied load: 10mA at 5 VDC (failure level: P reference value) Contact materials: AgSnIn • Transistor output: Open col ...
measurements of electrical quantities
... are steady in time. A label dc (Direct Current) is usually used for such quantities, and capital letters are used for symbols, e.g., Vdc . If the quantities vary in time, the label ac (Alternating Current) is usually used, e.g., Vac . Shape and repetition frequency of variations can be almost any. A ...
... are steady in time. A label dc (Direct Current) is usually used for such quantities, and capital letters are used for symbols, e.g., Vdc . If the quantities vary in time, the label ac (Alternating Current) is usually used, e.g., Vac . Shape and repetition frequency of variations can be almost any. A ...
Z-PACK HS3 6 Row ELECTRICAL PERFORMANCE REPORT Literature Number 1308505
... decision, these electrical performance criteria are becoming very important. Why use this EPR? The EPR provides system designers with fundamental data relating to the electrical performance of a connector. This data, in turn, allows the system designer to decide if the connector under analysis is th ...
... decision, these electrical performance criteria are becoming very important. Why use this EPR? The EPR provides system designers with fundamental data relating to the electrical performance of a connector. This data, in turn, allows the system designer to decide if the connector under analysis is th ...
Electricity Gone Wild
... you replaced all of the resistors in the circuit with one that was equal to the resistance of all of them, its resistance would be the equivalent resistance of the circuit. You can derive the equations for finding the equivalent resistance of parallel and series circuits from Kirchoff’s and Ohms law ...
... you replaced all of the resistors in the circuit with one that was equal to the resistance of all of them, its resistance would be the equivalent resistance of the circuit. You can derive the equations for finding the equivalent resistance of parallel and series circuits from Kirchoff’s and Ohms law ...
SN65EL11 数据资料 dataSheet 下载
... The device meets these specifications after thermal equilibrium has been established when mounted in a test socket or printed-circuit board with maintained transverse airflow greater than 500 lfpm (2.54 m/s). Electrical parameters are assured only over the declared operating temperature range. Funct ...
... The device meets these specifications after thermal equilibrium has been established when mounted in a test socket or printed-circuit board with maintained transverse airflow greater than 500 lfpm (2.54 m/s). Electrical parameters are assured only over the declared operating temperature range. Funct ...
Driven-right-leg circuit design (PDF Available)
... eI meet. the NFPA. safety standards by having an isolation capaci- filter with the series combination of Cb and Cs The circuit tance low enough to guarantee low current flow when line indicates a worst case phase shift because we have neglected voltage appears anywhere on the isolated amplifier: the ...
... eI meet. the NFPA. safety standards by having an isolation capaci- filter with the series combination of Cb and Cs The circuit tance low enough to guarantee low current flow when line indicates a worst case phase shift because we have neglected voltage appears anywhere on the isolated amplifier: the ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.