• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
CP0313
CP0313

... 4.1.3. Earth Fault Switching Tests (Test Duty 6a) Requirements This switch has been designed for use on systems with isolated neutrals. IEC 60265-1 clauses 1.101 and 6.101.8.6 require the breaking current be determined when the switch is operated during a phase-to-earth fault on one phase. Isolated ...
Fuse Facts and Fuse Selection Guide
Fuse Facts and Fuse Selection Guide

CR7931-NA108 Voltage Regulator Equipment
CR7931-NA108 Voltage Regulator Equipment

... it is disconnected from the exciter-field circuit so that it cannot affect the excitation of the a-c machine. This permits all the regulator equipment to be operated for test purposes. REGULATOR SIGNAL VOLTAGE When the control switch is at ON, the regulator is connected to the secondaries of potenti ...
Compile-Time Dynamic Voltage Scaling Settings: Opportunities and
Compile-Time Dynamic Voltage Scaling Settings: Opportunities and

... server and desktop systems due to exorbitant cooling, packaging and power costs. Dynamic voltage and frequency scaling (DVS) is a technique that allows the system to explicitly trade off performance for energy savings, by providing a range of voltage and frequency operating points. DVS allows one to ...
Geotech Natural Gamma Ray Logging System
Geotech Natural Gamma Ray Logging System

... 1.5” (3.8 cm) diameter. Located with the scintillator are the high voltage power supply and the pulse preamplifier, shaper, and amplifier circuitry. The probe requires approximately 9 VDC for proper operation. Voltage below this level may result in erratic output or a no output condition. The bottom ...
Click here to Technical Guidelines
Click here to Technical Guidelines

... 1. Shall be permitted on “first come first serve” basis (Cl. 3.1) 2. Cumulative Capacity of all Roof-top Solar PV (RT-SPV) Systems under Net Metering connected to a particular DT of RInfra shall not exceed 40 % of its Capacity (Cl.4.1) 3. RInfra shall provide information on Website regarding Solar c ...
IB 12 RECTIFYING AC Rectification: the process of converting an
IB 12 RECTIFYING AC Rectification: the process of converting an

MAX78615+PPM - Maxim Part Number Search
MAX78615+PPM - Maxim Part Number Search

... except the clock management circuitry and oscillators, which continue to run. The external reset input is filtered to prevent spurious reset events in noisy environments. The reset does not occur until RESET has been held low for at least 1µs. Once initiated, the reset mode persists until the RESET ...
V - Chi K. Tse
V - Chi K. Tse

... Let’s look at the logic behind these theorems (quite simple really). If we write down KVL, KCL, and Ohm’s law equations correctly, we will have a number of equations with the same number of unknowns. Then, we can try to solve them to get what we want. Now suppose everything is linear. We are sure th ...
MAX4927 1000 Base-T, ±15kV ESD Protection LAN Switch General Description Features
MAX4927 1000 Base-T, ±15kV ESD Protection LAN Switch General Description Features

... The MAX4927 switch provides an extremely low capacitance and on-resistance to meet Ethernet insertion and return-loss specifications. The MAX4927 features three built-in LED switches. The MAX4927 incorporates a unique architecture design utilizing only n-channel switches within the main Ethernet swi ...
Adjustable Battery-Backup Supervisor for RAM
Adjustable Battery-Backup Supervisor for RAM

... is asserted, the CE transmission gate is disabled when CEIN goes high, or 15 µs after reset asserts, whichever occurs first. This allows the current write cycle to complete during power down. When the CE transmission gate is enabled, the impedance of CEIN appears as a resistor in series with the loa ...
DICKSON ES120 PRO LOGGER OPERATION
DICKSON ES120 PRO LOGGER OPERATION

... Monitor on the Samples tab of the Setup screen. If unable to communicate, the battery voltage may already be low. • Verify transmitter is functioning properly. Try another transmitter. Verify wiring polarity and wire connection is secure. Verify correct switch settings. • These loggers are designed ...
Tutorial Problems
Tutorial Problems

... 3. A separately excited DC motor rated at 10KW, 240 V, 1000 rpm is supplied from a fully controlled two pulse bridge converter. The converter is supplied at 250 V, 50 Hz supply. An extra inductance is connected in the load circuit to make the conduction continuous. Determine the speed, power factor ...
New techniques for inverter flux control
New techniques for inverter flux control

A New Look At An Old Friend
A New Look At An Old Friend

... fall as the prevailing conditions dictate: if the AC line goes up, so does the B+ and the bias. If the AC line goes down, the opposite happens. It also happens to a smaller degree as the load on the power supply itself changes due to changing needs in power output. This too tends to cause both sourc ...
256-Position, Ultralow Power 1.8 V Logic
256-Position, Ultralow Power 1.8 V Logic

PSIM User Manual
PSIM User Manual

... If the zener diode is positively biased, it behaviors as a regular diode. When it is reverse biased, it will block the conduction as long as the cathode-anode voltage VKA is less than the breakdown voltage VB. Otherwise, the voltage VKA will be clamped to VB. ...
Designing a Three Phase Inverter for a Permanent Magnet Synchronous Motor
Designing a Three Phase Inverter for a Permanent Magnet Synchronous Motor

... Synchronous machines were first development during the middle of the 19th century as single phase generators to supply lighting systems. In the early development the salient pole rotor motor and the turbo generator formed as the typical design type. Being closely connected with the development of po ...
Achieving Optimal Efficiency in Energy Transfer to a CMOS Fully
Achieving Optimal Efficiency in Energy Transfer to a CMOS Fully

Two-electrode voltage
Two-electrode voltage

... As a negative feedback amplifier this kind of op-amp forms the central part of the voltage-clamp system (see Fig. 4). The positive input is connected to the potential VVC that is to be clamped to the memberane, the negative input to the signal provided by the potential measuring electrode. These two ...
Chapter 26 Powerpoint
Chapter 26 Powerpoint

A measurement-based approach to maximum power transfer for
A measurement-based approach to maximum power transfer for

... Thévenin’s theorem provides a two-parameter characterization of the behavior of a linear electrical network containing only voltage and current sources and linear circuit elements. It is one of the most celebrated results of linear circuit theory, because it provides computational and conceptual si ...
full paper - e-JST
full paper - e-JST

... data RAM. A key feature of the P89V51RD2 is its X2 mode option. In this microcontroller we can choose to run the application with the conventional 80C51 clock rate (12 clocks per machine cycle) or select the X2 mode (6 clocks per machine cycle) to achieve twice the throughput at the same clock frequ ...
VOD223T - Vishay
VOD223T - Vishay

... Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use ...
Zenergy Power Inc.
Zenergy Power Inc.

... • Purpose of Proposed Standard: To Provide Guidelines for Testing of Fault Current Limiters Operating on Condition-Based Impedance Increases for AC Systems 1000 V and Above ...
< 1 ... 557 558 559 560 561 562 563 564 565 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report