AXE102 PICAXE-08M2 Alarm / Steady Hand Kit
... 1) Place the 1k (brown black red gold) resistor in position. Bend the legs to hold the resistors in position and then solder. 2) The bottom resistor marked 1k may be a 1k or 10k resistor depending on the type of analogue sensor (e.g. LDR) used. Use10k (brown black orange gold) for a miniature style ...
... 1) Place the 1k (brown black red gold) resistor in position. Bend the legs to hold the resistors in position and then solder. 2) The bottom resistor marked 1k may be a 1k or 10k resistor depending on the type of analogue sensor (e.g. LDR) used. Use10k (brown black orange gold) for a miniature style ...
MC33975, MC9375A, Multiple Switch Detection Interface with
... The 33975 device has two modes of operation, Normal and Sleep. Normal mode allows programming of the device and supplies switch contacts with pull-up or pull-down current as it monitors the switch change of state. The Sleep mode provides low quiescent current, which makes the 33975 ideal for automot ...
... The 33975 device has two modes of operation, Normal and Sleep. Normal mode allows programming of the device and supplies switch contacts with pull-up or pull-down current as it monitors the switch change of state. The Sleep mode provides low quiescent current, which makes the 33975 ideal for automot ...
MAX5380/MAX5381/MAX5382 Low-Cost, Low-Power, 8-Bit DACs with 2-Wire Serial Interface in SOT23 General Description
... The MAX5380/MAX5381/MAX5382 are low-cost, 8-bit digital-to-analog converters (DACs) in miniature 5-pin SOT23 packages, with a simple 2-wire serial interface that allows communication with multiple devices. The MAX5380 has an internal +2V reference and operates from a +2.7V to +3.6V supply. The MAX53 ...
... The MAX5380/MAX5381/MAX5382 are low-cost, 8-bit digital-to-analog converters (DACs) in miniature 5-pin SOT23 packages, with a simple 2-wire serial interface that allows communication with multiple devices. The MAX5380 has an internal +2V reference and operates from a +2.7V to +3.6V supply. The MAX53 ...
NX-PD/PF/PC/TBX
... *1. You can use the unwired terminals of the Unit power supply terminals (UV/UG) for through-wiring of the Additional NX Unit Power Supply Unit or the Unit power supply terminals on the EtherCAT Coupler Unit. *2. The NC terminal is not connected to the internal circuit. ...
... *1. You can use the unwired terminals of the Unit power supply terminals (UV/UG) for through-wiring of the Additional NX Unit Power Supply Unit or the Unit power supply terminals on the EtherCAT Coupler Unit. *2. The NC terminal is not connected to the internal circuit. ...
Capacitive sensors: Ready for use at the push of a button
... the push of a button and have been optimised for the detection of conductive media through non-metal vessel walls. This small sensor has four functions: NO and NC function can be programmed by pressing two buttons. The autodetect output function allows the circuitry to detect PNP or NPN output loads ...
... the push of a button and have been optimised for the detection of conductive media through non-metal vessel walls. This small sensor has four functions: NO and NC function can be programmed by pressing two buttons. The autodetect output function allows the circuitry to detect PNP or NPN output loads ...
Efficient Excitation Signals for the Fast Impedance Spectroscopy
... A current mode excitation with pre-emphasized rising power spectrum at higher frequencies compensates a reducing response of impedance in the high frequency range beginning from 100 kHz in Fig. 1(a). The rise of impedance in lower frequency area is mostly caused by polarization of electrodes (double ...
... A current mode excitation with pre-emphasized rising power spectrum at higher frequencies compensates a reducing response of impedance in the high frequency range beginning from 100 kHz in Fig. 1(a). The rise of impedance in lower frequency area is mostly caused by polarization of electrodes (double ...
Highest accuracy & precision WT3000E Precision Power Analyzer
... The WT3000E can perform measurements on up to 4 power input elements in a single unit. This enables users to simultaneously measure single-phase input/three-phase output, or three-phase input/three-phase output. Accurate measurement of fundamental PWM voltage Motor drive technology has become more c ...
... The WT3000E can perform measurements on up to 4 power input elements in a single unit. This enables users to simultaneously measure single-phase input/three-phase output, or three-phase input/three-phase output. Accurate measurement of fundamental PWM voltage Motor drive technology has become more c ...
Integrated Circuit Design of Sigma-Delta Modulator for
... Advisor: Antonio Petraglia Department: Electrical Engineering The design of a sigma-delta modulator as part of an analog-to-digital converter for a monolithic electric energy measurement system is presented. The main requirements such applications are a resolution of 16 bits and a bandwidth ranging ...
... Advisor: Antonio Petraglia Department: Electrical Engineering The design of a sigma-delta modulator as part of an analog-to-digital converter for a monolithic electric energy measurement system is presented. The main requirements such applications are a resolution of 16 bits and a bandwidth ranging ...
Instruction manual - english - Digi-Sonic III System
... The text and graphics of this manual have been elaborated with the greatest possible care. However, we may not be held liable for possible errors and failure effects. Should you wish to make suggestions regarding the arrangement of this manual or point out possible errors, please contact your local ...
... The text and graphics of this manual have been elaborated with the greatest possible care. However, we may not be held liable for possible errors and failure effects. Should you wish to make suggestions regarding the arrangement of this manual or point out possible errors, please contact your local ...
RE1L002SN
... shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability th ...
... shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability th ...
exp04
... Since op-amps are used as amplifiers, they need an external source of (constant DC) power. Typically, this source will supply +15V at +V and -15V at -V. We will use ±9V. The op-amp will output a voltage range of of somewhat less because of internal losses. The power supplied determines the output ...
... Since op-amps are used as amplifiers, they need an external source of (constant DC) power. Typically, this source will supply +15V at +V and -15V at -V. We will use ±9V. The op-amp will output a voltage range of of somewhat less because of internal losses. The power supplied determines the output ...
Suggested Specification
... Automatic/Manual Control: The Control shall have user-selectable control on the front panel for Automatic or Manual operation. In addition, it shall have an option for SCADA command to change the Auto/Manual control state remotely. Automatic/Manual Switch Status: The control shall provide indication ...
... Automatic/Manual Control: The Control shall have user-selectable control on the front panel for Automatic or Manual operation. In addition, it shall have an option for SCADA command to change the Auto/Manual control state remotely. Automatic/Manual Switch Status: The control shall provide indication ...
Solid State Relays Common Precautions
... The supply voltage plus the charge voltage of the capacitor is applied to both ends of the SSR when it is OFF. Therefore, use an SSR model with an input voltage rating twice the size of the supply voltage. Limit the charge current of the capacitor to less than half the peak inrush current value allo ...
... The supply voltage plus the charge voltage of the capacitor is applied to both ends of the SSR when it is OFF. Therefore, use an SSR model with an input voltage rating twice the size of the supply voltage. Limit the charge current of the capacitor to less than half the peak inrush current value allo ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.