• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Voltage Transducer LV 25-600 V PN = 600 V
Voltage Transducer LV 25-600 V PN = 600 V

... Reinforced insulation ...
Avoiding Operational Amplifier Output Stage Saturation by Gain
Avoiding Operational Amplifier Output Stage Saturation by Gain

Getting started on the HP3577 network analyzer
Getting started on the HP3577 network analyzer

MultiPlus Inverter/Charger
MultiPlus Inverter/Charger

... The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC l ...
bravida s-node - Panasonic Business
bravida s-node - Panasonic Business

... racks. Passing through cables is either on the underside or through the back. The whole construction is designed in order to be able to effect a correct and rapid installation with a minimum of connection materials. The circuit board has removable terminal blocks for easy installation and maintenanc ...
Utilizing Reverse Short Channel Effect for Optimal
Utilizing Reverse Short Channel Effect for Optimal

... • Multi-VDD Techniques and Conventional Level converters are introduced. • Conventional Level converters will introduce DC current and feedback circuit (hence slow response) • Multi-Vth Level converters will eliminate DC current and Feedback circuit. ...
CASCADED MULTILEVEL INVERTER WITH SERIES
CASCADED MULTILEVEL INVERTER WITH SERIES

Understanding Delta Conversion On-line "Power Regulation"
Understanding Delta Conversion On-line "Power Regulation"

... The magnitude of the input current is controlled by PWM current control circuit (blue circuit). By monitoring the DC bus voltage just like a double conversion rectifier charger control system, we set the magnitude of input current to maintain the DC bus voltage. We do this by setting the delta inve ...
Ohms - HCC Learning Web
Ohms - HCC Learning Web

... 1) Convert the unit of OHM into its combination of the fundamental SI units. ...
Electric Current and Electrical Energy
Electric Current and Electrical Energy

... Generating Electrical Energy, continued ...
MAX2204EVKIT.pdf
MAX2204EVKIT.pdf

... Do not turn on the DC power or RF signal generators until all connections are made: 1) Set the jumper (JP1) on the EV kit to ON. This enables the device. 2) Connect a DC supply set to +2.85V (through a DMM, if desired) to the VCC and GND terminals on the EV kit. If available, set the current limit t ...
Radio Frequency Power Amplifier
Radio Frequency Power Amplifier

... phasing, as shown by the dots on the primary and secondary windings. When the switch is on, the input voltage is forced across the transformer primary which causes an increasing flow of current through it. The dot-negative voltage appearing across the secondary winding turns off the diode, preventin ...
Three Phase Fault Analysis with Auto Reset for Temporary
Three Phase Fault Analysis with Auto Reset for Temporary

Physics  Time: 3 Hours Max. Marks: 70
Physics Time: 3 Hours Max. Marks: 70

... 7. A lamp is connected in series with an inductor to a d.c. source. What will happen to its glow, when it is connected directly to the same source? 8. How does the energy gap in a semiconductor vary, when doped with a pentavalent impurity? 9. An electric dipole is held in a uniform electric field. ( ...
ATP-Y/Analog Input to Pulse (Relay)
ATP-Y/Analog Input to Pulse (Relay)

... isolated from earth ground, chassis ground, and neutral leg of the primary winding. If required by BAS or controller specification, the 24 VAC neutral can be earth grounded at the transformer. Analog input, digital input, and analog output circuits should not be earth grounded at two points. Any fie ...
AVOP-ELEKTRO-SMI-010
AVOP-ELEKTRO-SMI-010

... the value of the measured voltage deviation or figure. ...
Mobile Electric-Discharge Blasting Unit for Splitting off and
Mobile Electric-Discharge Blasting Unit for Splitting off and

... by a number of the connected modules. The bus bars were made from copper of 3 mm thickness and 60 mm width. An assembled capacitor bank is shown in Figure 1b. The power supply was designed to get output power up to 3kVA. It consists of industrial frequency step-up transformer with single-stage volta ...
Electrical and Electronics Engineering Department
Electrical and Electronics Engineering Department

Section 11.3: Electric Potential Difference
Section 11.3: Electric Potential Difference

Practical Activities with Photovoltaic Panels
Practical Activities with Photovoltaic Panels

...  The experiment should also be performed quickly to avoid overheating of the panel that may then change the characteristics during the data-collection  Make sure that you don’t cast any shadows or reflections over the panel during the experiment.  Set-up the circuit below (using the middle and ei ...
Syllabus (8th Semester)
Syllabus (8th Semester)

... Objective:  The course is introduced to the students to enable them to give optimal performance and  to tackle every challenge during professional experience.  ...
1.0 Scope 1.1. This specification documents the
1.0 Scope 1.1. This specification documents the

... 7.5. INPUT OVERLOAD PROTECTION The ADA4096-2S inputs are protected from input voltage excursions up to 32V outside each rail. This feature is of particular importance in applications with power supply sequencing issues that could cause the signal source to be active before these supplies to the amp ...
16.3 and 16.4
16.3 and 16.4

Why bother to study crystal radios
Why bother to study crystal radios

... adjusted to the value of Vref. Instead, use the existing ±10 V supplies to provide power to a voltage reference circuit of your own design. Keep in mind that the current flowing through R1 is not negligible. You may design the voltage reference circuit around a second op-amp. Be sure to record all ...
PPT - hss-1.us
PPT - hss-1.us

... PV modules with different current outputs connected in series PV modules with lower current output will absorb current from modules with higher current output. Will lead to loss of power and potential overheating/damage of lower current PV modules ...
< 1 ... 2435 2436 2437 2438 2439 2440 2441 2442 2443 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report