• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
5A Range AC Current Transformer Current Sensor Module
5A Range AC Current Transformer Current Sensor Module

ECE445 Projects
ECE445 Projects

... The transfer function of the controller, with the particular pole and zero values determined. A Matlab Bode plot the loop gain. (Use the Matlab MARGIN command.) A Matlab Bode plot of the open and closed loop audio-susceptibility (on the same plot). A Matlab Bode plot of the open and closed loop outp ...
TD62083AFNG,TD62084AFNG - Toshiba America Electronic
TD62083AFNG,TD62084AFNG - Toshiba America Electronic

... • This document and any information herein may not be reproduced without prior written permission from TOSHIBA. Even with TOSHIBA’s written permission, reproduction is permissible only if reproduction is without alteration/omission. • Though TOSHIBA works continually to improve Product’s quality and ...
Introduction - facstaff.bucknell.edu
Introduction - facstaff.bucknell.edu

six light troubleshooting.fm
six light troubleshooting.fm

... The Status Light Panel is normally located on the Electrical Panel. All six lights are illuminated when the system is in proper working order. The lights turn on in a sequence and will stop at the point where a fault is first detected. ...
a two stage isolated bidirectional dc/dc convertor for pv
a two stage isolated bidirectional dc/dc convertor for pv

... iLrp starts to flow through the body diode of M2, and the ON state of the body diode of M3 is maintained to provide the current path of iLrs. When M2 and M4 are turned on at t4, ZVS of M2 is accomplished, and iLrs flows through the channel ofM4 and Cr. After t5, iLrp changes its direction, flowing t ...
Warnings, information and notes regarding designation of the product
Warnings, information and notes regarding designation of the product

... Auxiliary power supply can be LOW range (19-70VDC, 48-77VAC). Connecting device with LOW power supply to higher voltage will cause device malfunction. Check devices’ specification before turn it on! ...
Electric Fitting (New)
Electric Fitting (New)

... (kilo-volt-amp) rating of three-phase transformers is about 150% greater than that for single-phase motors or transformers with a similar frame size. ...
network and theorems trainers
network and theorems trainers

... Superposition and maximum power transfer Theorem Trainer  Built in fixed power supply of +5V.  Built in variable power supply of 0-12V.  Super position and maximum power transfer circuits are in one board. ...
LTC6268 DICE - 500MHz Ultra-Low Bias Current FET Input Op Amp
LTC6268 DICE - 500MHz Ultra-Low Bias Current FET Input Op Amp

... Note 2: The inputs are protected by two series connected ESD protection diodes to each power supply. The input current should be limited to less than 1mA. The input voltage should not exceed 200mV beyond the power supply. ...
manual
manual

... Last week you looked at the behavior of a capacitor in a DC circuit. Briefly, at the end, you looked at how the voltage across the capacitor changed as a function of the frequency in an AC circuit. This week you will look at AC circuits in more detail. Consider what happens in a series circuit consi ...
How to Select the External Components for an
How to Select the External Components for an

DM7442A BCD to Decimal Decoder
DM7442A BCD to Decimal Decoder

... BCD to Decimal Decoder General Description ...
work sheet 1 unit-1 two port network theory
work sheet 1 unit-1 two port network theory

Chapter 22 Outline
Chapter 22 Outline

... The key to ESD prevention is to keep all electronic components and yourself at a common electrical potential. a. “Grounding” yourself is as easy as touching the metal computer chassis before handling components. ...
DM7400 Quad 2-Input NAND Gates
DM7400 Quad 2-Input NAND Gates

... 14-Lead Plastic Dual-In-Line Package (PDIP), JEDEC MS-001, 0.300 Wide Package Number N14A ...
LX1FG220 - Schneider Electric
LX1FG220 - Schneider Electric

... TeSys F - contactor coil - LX1FG - 220...230 V AC 50 Hz - 265...277 V AC 60 Hz ...
RB151 - Rectron Semiconductor
RB151 - Rectron Semiconductor

Section 1 Electric Charge
Section 1 Electric Charge

... b. Example: the electrical system in a _________ B. Household circuits use ____________ circuits connected in a logical network. 1. Each branch receives the standard ______________________ from the electric company. 2. Electrical energy enters your home at the ___________ breaker or ________ box and ...
2-Stage Parallel-to-Series, ENERGY STAR Low-Cost
2-Stage Parallel-to-Series, ENERGY STAR Low-Cost

Voltage Transfer Characteristic
Voltage Transfer Characteristic

... Get the values of x and y intercepts from the derived IC versus VCE. Draw the curve of IB and obtained the intercept points IC and VCE (for npn) or VEC (for pnp) which is also known as the Q points ...
CIRCUIT FUNCTION AND BENEFITS
CIRCUIT FUNCTION AND BENEFITS

... The 0.1 µF capacitor decouples the reference between its input and output pins. The 1 kΩ resistor isolates the capacitor from the inverting input of the op amp. A low inductance 0.1 µF ceramic decoupling capacitor (not shown in the figure) should ...
TL072__5V - TI E2E Community
TL072__5V - TI E2E Community

An Improved Topology for Symmetric, Asymmetric and
An Improved Topology for Symmetric, Asymmetric and

... consists of a series-connected main high-, medium- and low-voltage stages. The high-voltage stage is made of a three-phase, six-switch inverter. The medium- and lowvoltage stages are made of three-level inverters constructed by H-bridge units. The proposed control strategy assumes a reference input ...
54315 Trailer Remote Receptacle.fm
54315 Trailer Remote Receptacle.fm

... REMOTE POWER RECEPTACLE INSTALLATION GUIDELINES For SB Trailer Units with SmartPower™ Option DANGER: An improperly installed remote power receptacle could lead to serious injury or death! Only a qualified electrician should perform this installation. DANGER: The remote power cable must be physically ...
< 1 ... 2403 2404 2405 2406 2407 2408 2409 2410 2411 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report