• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
8. operation instructions
8. operation instructions

... INPUT – No AC Voltage is detected on the input of the UPS. CHARGER - The LED will illuminate continuously when the charger fails to deliver the necessary voltage to charge the batteries. The LED will flash if the Battery Breaker is open. FAULT - tells the operator that one or both DC rectifiers have ...
Miller Compensation in Two
Miller Compensation in Two

... Simulate the common mode result ...
2. electric motors - Bureau of Energy Efficiency
2. electric motors - Bureau of Energy Efficiency

... Induction motors are the most commonly used prime mover for various equipments in industrial applications. In induction motors, the induced magnetic field of the stator winding induces a current in the rotor. This induced rotor current produces a second magnetic field, which tries to oppose the stat ...
Version 2.0
Version 2.0

... correct. It does not necessarily have accurate per-pin or coupled package modeling, may not have information needed to check timing, and may not have information to help measure power currents. IQ2 includes all items in IQ1, plus all items designated “{LEVEL 2}”. 1.1.4. IQ3 – Suitable for Timing Ana ...
Analysis of fully differential amplifiers
Analysis of fully differential amplifiers

... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
Document
Document

... ECE 3301 General Electrical Engineering Section 18 Thevenin Equivalent Circuit Theorem ...
2 The Junction Diode 3
2 The Junction Diode 3

Device Noise
Device Noise

... low pass anti-aliasing filter is not used in this circuit, the noise contribution due to the resistors in Figure 1 is significant. Capacitors: In noise discussions, capacitors are generally identified as devices that reduce or filter system noise. Capacitors are most frequently categorized by the d ...
Device Noise
Device Noise

... low pass anti-aliasing filter is not used in this circuit, the noise contribution due to the resistors in Figure 1 is significant. Capacitors: In noise discussions, capacitors are generally identified as devices that reduce or filter system noise. Capacitors are most frequently categorized by the d ...
Superconducting Fault Current Limiters
Superconducting Fault Current Limiters

... To help establish a fundamental understanding of SFCL technologies, this section provides a simplified and hopefully effective overview by condensing various design concepts into three SFCL types. The first two types depend on the quenching action of superconductors and the third type uses DC HTS m ...
explanatory memo issued by the info-communications
explanatory memo issued by the info-communications

... requirements of the EMC Directive (2014/30/EU) for adequate level of EMC to avoid interference; and Low Voltage Directive (“LVD”, 2014/35/EU) for safety of use. These two Directives are essential parts of the Radio Equipment Directive5 (“RED”, 2014/53/EU) enforced in the European Union (“EU”) for m ...
Protected against direct spray of water from all - Consultations
Protected against direct spray of water from all - Consultations

... so as to prevent danger, and (b) all electrical equipment and electrical installations, including distribution boards, sockets, transformers and connections, are suitably protected from ingress of moisture or of particles and foreseeable impacts, as appropriate to the location. 3.2 Design and constr ...
Reference Voltage (VREF )
Reference Voltage (VREF )

Document
Document

... 2. Typically conductors are laid in parallel lines. Where it is practical, the conductors are laid along the structures or rows of equipment to provide short ground connections. 3. Typical substation grid systems may include 4/0 bare copper conductor buried 0.3-0.5 m (12-18 in) below grade and space ...
AN11075 Driving I2C-bus signals over twisted pair cables with
AN11075 Driving I2C-bus signals over twisted pair cables with

... Using multiple PCA9605 buffers, or PCA9646 fully buffered bus switches, to ‘regenerate’ clean drive signals allows building large area distributed control systems suitable for controlling I2C-bus LED drivers for signs or architectural lighting. Simpler systems, with just a few buffers, still allow q ...
1. INTRODUCTION The history of semiconductor devices starts in
1. INTRODUCTION The history of semiconductor devices starts in

... digital chip, the analog circuit blocks must have available critical passive components, such as resistors and capacitors. Digital blocks, in contrast, require only n-channelmetal-oxide semiconductor (NMOS) and p-channel ...
BDTIC www.BDTIC.com/infineon  RF & Protection Devices
BDTIC www.BDTIC.com/infineon RF & Protection Devices

... The BGS12AL7-6 General Purpose RF MOS switch is designed to cover a broad range of applications from 30 MHz to 3 GHz. The symmetric design of its single pole double throw configuration, as shown in Figure 1 offers high design flexibility. This single supply chip integrates on-chip CMOS logic driven ...
CPLD I/O User Guide www.BDTIC.com/XILINX UG445 (v1.0) June 26, 2007
CPLD I/O User Guide www.BDTIC.com/XILINX UG445 (v1.0) June 26, 2007

... The CoolRunner XPLA3 has a half latch feature on the I/Os. The half latch is essentially a pull-up that turns on only when the I/O pin voltage is in the linear region (not a 0, not a 1). So, when the voltage at the pin is in the trip-point region or higher, the half latch will be enabled. The idea i ...
STUDY OF VARIOUS ELECTRICAL SYMBOLS AND TOOLS
STUDY OF VARIOUS ELECTRICAL SYMBOLS AND TOOLS

... the line current and in phase with it. The potential coil has, as a general rule, a high-value resistor connected in series with it to reduce the current that flows through it. The result of this arrangement is that on a dc circuit, the deflection of the needle is proportional to both the current an ...
AD1955 数据手册DataSheet下载
AD1955 数据手册DataSheet下载

... can be used with any word length up to 24 bits. In this mode, it is the responsibility of the DSP to ensure that the left data is transmitted with the first LRCLK pulse after RESET, and that synchronism is maintained from that point forward. In Right-Justified Mode (16 bits shown), LRCLK is high for ...
Rebuilding a Potassium Quantum Gas Apparatus
Rebuilding a Potassium Quantum Gas Apparatus

... can deliver around 1 W of power, this is sufficient for driving the AOMs. The ZOS-300 VCO has a pre-amplifier attached to its output (mini-circuits ZFL-500LN) in order to provide enough power to drive the main amplifier (ZHL-3A), which in turn provides the required power for the AOM. One of our AOMs ...
ADTS - MS Word Document
ADTS - MS Word Document

... monitor shall be equal to ASCO Feature 27. I. The controller shall be capable of accepting a normally open contact that will allow the transfer switch to function in a non-automatic mode when a non-automatic version of the user interface membrane is furnished. J. Engine Exerciser – The controller sh ...
Datasheet - Texas Instruments
Datasheet - Texas Instruments

... The individual PWM controller allows each LED to be set to a specific brightness value. An additional 8-bit resolution (256 steps) group PWM controller has both a fixed frequency of 190-Hz and an adjustable frequency between 24-Hz to once every 10.73 seconds, with a duty cycle that is adjustable fro ...
SureFire IITM Electrical High Tension Igniter type HTSS Instruction
SureFire IITM Electrical High Tension Igniter type HTSS Instruction

... VDC control signal from the Burner Management System operates an internal relay which powers the HV ignition transformer, which in turn creates an 8000 VAC spark at the igniter tip. After the trial for ignition, the 24 VDC control signal is switched off, the relay changes state to allow ionization d ...
Grid Tied Inverter 1,5 / 3 / 5 kW User Manual
Grid Tied Inverter 1,5 / 3 / 5 kW User Manual

< 1 ... 223 224 225 226 227 228 229 230 231 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.