• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
2N3773
2N3773

... hFE (1) ...
TAP 126- 2: Measuring the charge on a capacitor
TAP 126- 2: Measuring the charge on a capacitor

... spdt switch ...
AD633 Data Sheet
AD633 Data Sheet

... Figure 13 shows two multipliers being used to form integrators with controllable time constants in a 2nd order differential equation feedback loop. R2 and R5 provide controlled current output operation. The currents are integrated in capacitors C1 and C2, and the resulting voltages at high impedance ...
EMX2
EMX2

... Fig.7 Collector-emitter saturation voltage vs. collector current ( Ι ) ...
PANIMALAR ENGINEERING COLLEGE
PANIMALAR ENGINEERING COLLEGE

... THE 555 TIMER AS AN ASTABLE MULTIVIBRATOR An Astable multivibrator, often called a free running multivibrator, is a rectangular wave generating circuit. Unlike the monostable multivibrator, this circuit does not require an external trigger to change the state of the output, hence the name free runni ...
Ohms_law
Ohms_law

Electricity
Electricity

... Calculate the maximum charge stored by the capacitor Calculate the maximum energy stored by the capacitor How would you know when the capacitor is fully charged Draw a graph to show how the current varies with time from the moment the circuit is switched on (values on current axis only) (f) On the s ...
Power Consumption
Power Consumption

... Most installations do not know the input watts without finding out from the pump manufacturer. Another method is given if the known is duty cycle, voltage, amperage, and power factor. First, we must convert the electrical readings to an input power (kilowatt): input power = (voltage) * (amperage) * ...
MAX44299 Current and Voltage Sense with Power Measurement
MAX44299 Current and Voltage Sense with Power Measurement

... • Power, Current, and Voltage Monitoring Plus Reference • 5mV, 10mV, and 20mV Programmable CurrentSensing Full-Scale Voltage • Calibration Point at 10µA upon Command ...
GNS ESI RF2173
GNS ESI RF2173

... The part will operate over a 3.0V to 5.0V range. Under nominal conditions, the power at 3.5V will be greater than +34.5dBm at +90°C. As the voltage is increased, however, the output power will increase. Thus, in a system design, the ALC (Automatic Level Control) Loop will back down the power to the ...
x8407_projects
x8407_projects

... Rated Inverter Output Voltage: 6.6KV (rms fundamental line-to-line voltage) Rated Inverter Output Power: 5MVA (three-phase) Rated Inverter Output Frequency: 60Hz dc link voltage: Constant, ripple free. Total dc link voltage: To be determined. Use two identical dc voltage sources for the three-level ...
VFD Fundamentals
VFD Fundamentals

SN_presentation_General_Nov_10_2009 - Indico
SN_presentation_General_Nov_10_2009 - Indico

... inductance. This is not neccesary when running pulses >>10 us NEXT ...
SL MA-110 Optical Transmittance Analyzer  SPECIFICATIONS
SL MA-110 Optical Transmittance Analyzer SPECIFICATIONS

Chapter 15 Power Supplies (Voltage Regulators)
Chapter 15 Power Supplies (Voltage Regulators)

... Copyright ©2009 by Pearson Education, Inc. Upper Saddle River, New Jersey 07458 • All rights reserved. ...
NLHVQ011 - 1-Bit Gate Pulse Modulator
NLHVQ011 - 1-Bit Gate Pulse Modulator

Time Delay Relays – Application Data
Time Delay Relays – Application Data

... As noted above, this trigger signal can either be a control switch (dry contact switch) or a power trigger (voltage). Output (Load): Every time delay relay has an internal relay (usually mechanical) with contacts that open & close to control the load. They are represented by the dotted lines in the ...
A Novel Approach in Design of a Fuzzy Based Shunt Active Power
A Novel Approach in Design of a Fuzzy Based Shunt Active Power

... voltage are fed to add block with negative sign. These two blocks are available in Simulink library Browser. The output of product block is fed to load active power calculation block. The output of add block is fed to fuzzy voltage controller. Finally providing gain as circuit design parameter, hyst ...
model ps250 installation and service
model ps250 installation and service

... For access control applications, batteries are optional. When batteries are not used, the loss of AC will result in the loss of output voltage. C. Instructions. 1. Set the desired voltage. See table 1. 2. If backup battery is desired, connect battery to battery terminals (“BAT”). Carefully observe p ...
U5220-XL-75 125A UNMET DBL DB PED 784572266407
U5220-XL-75 125A UNMET DBL DB PED 784572266407

... Cable Size: ...
Ex. For the circuit shown find the a) current in each
Ex. For the circuit shown find the a) current in each

Lab 5: Frequency Response of an Op Amp Circuit
Lab 5: Frequency Response of an Op Amp Circuit

... Exercise 2: Measuring Gain and Phase Suggested values are: R1 = in the range of 2 k to 5 k R2 = in the range of 5 k to 10 k C in the range of 0.07 μF to 0.5 μF. Collect the required components; measure and record their values. Build the circuit and connect it to a sinusoidal source (FG). Test th ...
ECE - 703 - NIT Arunachal Pradesh
ECE - 703 - NIT Arunachal Pradesh

... D-latch and edge-triggered circuits, Schmitt trigger circuit, Comparator, Dynamic Logic Circuit: Pass transistor logic, synchronous dynamic circuit techniques, Semiconductor Memories: ROM circuit, SRAM circuits, DRAM circuits, drivers and buffers, Buffer scaling and design issues Review of MOSFET ch ...
Grounding and Shielding Existing Equipment
Grounding and Shielding Existing Equipment

... single ended and a high gain. There’s the key, ground differentials and low frequency. In today’s circuitry differential inputs are used to resolve the 60 Hz noise caused from ground differentials. Thus, the rules have not changed; but the technology has. In those sporadic cases where one has a sing ...
a AN-584 APPLICATION NOTE
a AN-584 APPLICATION NOTE

... approximately equal to the mid-supply point (average value of the voltages on V+ and V–). Relying on this internal bias will result in an output common-mode voltage that is within about 100 mV of the expected value. In cases where more accurate control of the output commonmode level is required, it ...
< 1 ... 1932 1933 1934 1935 1936 1937 1938 1939 1940 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report