Digital and Analog I/O
... Expansion Boards for the ION7700 The ION7700 expansion boards provide multiple analog and digital inputs, analog outputs, digital inputs, and/or digital outputs. Up to two expansion boards can be connected to the ION7700 meter, though the second board requires its own power supply. (The first exp ...
... Expansion Boards for the ION7700 The ION7700 expansion boards provide multiple analog and digital inputs, analog outputs, digital inputs, and/or digital outputs. Up to two expansion boards can be connected to the ION7700 meter, though the second board requires its own power supply. (The first exp ...
HiAll APPLICATION NOTE
... The aim of this document is to provide technical guidelines to help the customer to design solutions based on NC HiAll module. ...
... The aim of this document is to provide technical guidelines to help the customer to design solutions based on NC HiAll module. ...
Mixed Swing Techniques for Low Energy/Operation Datapath Circuits
... position my research better against competing work in the industry. Interactions with the industry have played a vital role in this research. I would like to express my gratitude to Dr. Shekhar Borkar, Dr. Vivek De, and Dr. Soumya Krishnamurthy of Microprocessor Research Labs, Intel Corporation, for ...
... position my research better against competing work in the industry. Interactions with the industry have played a vital role in this research. I would like to express my gratitude to Dr. Shekhar Borkar, Dr. Vivek De, and Dr. Soumya Krishnamurthy of Microprocessor Research Labs, Intel Corporation, for ...
Electronic Components
... Wire gauge and physical size of the coil determine the current handling capacity. Core material will have a temperature dependence. Air is best, followed by iron powder, then ferrites. LSU 08/11/2004 ...
... Wire gauge and physical size of the coil determine the current handling capacity. Core material will have a temperature dependence. Air is best, followed by iron powder, then ferrites. LSU 08/11/2004 ...
OPERATIONAL TRANSCONDUCTANCE AMPLIFIERS FOR GIGAHERTZ APPLICATIONS You Zheng
... intermodulation distortion, which is of particular interest in microwave circuits. The OTA’s noise behavior and the effects of process variations, device mismatch, and power supply noise on the transconductance are also studied. To the best of our knowledge, the noise analysis here is the first of i ...
... intermodulation distortion, which is of particular interest in microwave circuits. The OTA’s noise behavior and the effects of process variations, device mismatch, and power supply noise on the transconductance are also studied. To the best of our knowledge, the noise analysis here is the first of i ...
a CMOS, +1.8 V to +5.5 V/ Low-Voltage, 8-/16-Channel Multiplexers ADG706/ADG707
... Low-power consumption and operating supply range of 1.8 V to 5.5 V make the ADG706 and ADG707 ideal for battery-powered, portable instruments. All channels exhibit break-before-make switching action preventing momentary shorting when switching channels. These devices are also designed to operate fro ...
... Low-power consumption and operating supply range of 1.8 V to 5.5 V make the ADG706 and ADG707 ideal for battery-powered, portable instruments. All channels exhibit break-before-make switching action preventing momentary shorting when switching channels. These devices are also designed to operate fro ...
ignition systems - Das Offroad Forum
... HYFIRE® 6 EZL Digital CD Ignition Features At A Glance: • Power up and go • High output multi-spark ignition system provides quicker acceleration and throttle response • Digital microprocessor controlled circuitry provides more performance and lower power draw • Built-in easy-to-adjust digital rev l ...
... HYFIRE® 6 EZL Digital CD Ignition Features At A Glance: • Power up and go • High output multi-spark ignition system provides quicker acceleration and throttle response • Digital microprocessor controlled circuitry provides more performance and lower power draw • Built-in easy-to-adjust digital rev l ...
sevcon sc2000 manual
... * Hours Counter displaying Key Switch, Pump and Traction pulsing hours on calibrator. * BDI. Battery discharge indicator with adjustable warning and cut out levels. * Dual motor non proportional and proportional variants with steer switch or steer pot inputs. * Dual Motor steer angles can be adjuste ...
... * Hours Counter displaying Key Switch, Pump and Traction pulsing hours on calibrator. * BDI. Battery discharge indicator with adjustable warning and cut out levels. * Dual motor non proportional and proportional variants with steer switch or steer pot inputs. * Dual Motor steer angles can be adjuste ...
Back-UPS™ 350/500
... on the rear panel of the Back-UPS) by pushing the circuit breaker button fully inward until it catches. If the circuit breaker resets, switch the Back-UPS on and reconnect the equipment one-at-a-time. If the circuit breaker trips again, it is likely that one of the connected devices is causing the o ...
... on the rear panel of the Back-UPS) by pushing the circuit breaker button fully inward until it catches. If the circuit breaker resets, switch the Back-UPS on and reconnect the equipment one-at-a-time. If the circuit breaker trips again, it is likely that one of the connected devices is causing the o ...
TSHG6210
... Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use ...
... Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use ...
DC system specification
... Cubicle sizes and overall views shall be co-ordinated with. d.c. distribution panels as they shall be erected in the same room. ...
... Cubicle sizes and overall views shall be co-ordinated with. d.c. distribution panels as they shall be erected in the same room. ...
Owner`s Manual
... when AC power from an external source is connected to the output of the inverter. Inspect wiring for a possible input/output wiring error. This condition must be corrected before further operation. A backfeed will damage the unit and void the warranty. Battery Type Selection • Battery type setup. To ...
... when AC power from an external source is connected to the output of the inverter. Inspect wiring for a possible input/output wiring error. This condition must be corrected before further operation. A backfeed will damage the unit and void the warranty. Battery Type Selection • Battery type setup. To ...
Back-UPS™ 350/500 CS
... on the rear panel of the Back-UPS) by pushing the circuit breaker button fully inward until it catches. If the circuit breaker resets, switch the Back-UPS on and reconnect the equipment one-at-a-time. If the circuit breaker trips again, it is likely that one of the connected devices is causing the o ...
... on the rear panel of the Back-UPS) by pushing the circuit breaker button fully inward until it catches. If the circuit breaker resets, switch the Back-UPS on and reconnect the equipment one-at-a-time. If the circuit breaker trips again, it is likely that one of the connected devices is causing the o ...
SKY73090-21 数据资料DataSheet下载
... The SKY73090-21 is a fully integrated diversity mixer that includes Local Oscillator (LO) drivers, an LO switch, high linearity mixers, and large dynamic range Intermediate Frequency (IF) amplifiers. Low loss RF baluns have also been included to reduce design complications and lower system cost. The ...
... The SKY73090-21 is a fully integrated diversity mixer that includes Local Oscillator (LO) drivers, an LO switch, high linearity mixers, and large dynamic range Intermediate Frequency (IF) amplifiers. Low loss RF baluns have also been included to reduce design complications and lower system cost. The ...
A 1 GS/s 6 bits Time-Based Analog-to
... List of Figures Figure 1 : Analog-to-Digital Conversion ....................................................................... 1 Figure 2 : Generic digital signal processing system ...................................................... 2 Figure 3 : Future digital signal processing system.......... ...
... List of Figures Figure 1 : Analog-to-Digital Conversion ....................................................................... 1 Figure 2 : Generic digital signal processing system ...................................................... 2 Figure 3 : Future digital signal processing system.......... ...
AD7685 数据手册DataSheet下载
... Chain mode is selected if SDI is low during the CNV rising edge. In this mode, SDI is used as a data input to daisy chain the conversion results of two or more ADCs onto a single SDO line. The digital data level on SDI is output on SDO with a delay of 16 SCK cycles. CS mode is selected if SDI is hig ...
... Chain mode is selected if SDI is low during the CNV rising edge. In this mode, SDI is used as a data input to daisy chain the conversion results of two or more ADCs onto a single SDO line. The digital data level on SDI is output on SDO with a delay of 16 SCK cycles. CS mode is selected if SDI is hig ...
W15PTOS/E - Winco Inc.
... isolation transfer switch must be used with a standby generator. The transfer switch isolates the load from the power line and allows you to safely operate your loads without endangering the power line repair crew. See page 4. The load, connected to the normal terminals of the transfer switch, is en ...
... isolation transfer switch must be used with a standby generator. The transfer switch isolates the load from the power line and allows you to safely operate your loads without endangering the power line repair crew. See page 4. The load, connected to the normal terminals of the transfer switch, is en ...
Peak Power Tracking and Multi-Thruster Control in Direct Drive
... cathodes connected electrically to ground. Under the nominal test conditions one of the two cathodes drew approximately 90% of the total discharge current.25 Finally, and most relevant for the work described here, Beal et al.20 operated two BHT-200 thrusters in parallel from a single discharge power ...
... cathodes connected electrically to ground. Under the nominal test conditions one of the two cathodes drew approximately 90% of the total discharge current.25 Finally, and most relevant for the work described here, Beal et al.20 operated two BHT-200 thrusters in parallel from a single discharge power ...
BQ2063 数据资料 dataSheet 下载
... record of available charge in Li-Ion batteries. The bq2063 monitors capacity and other critical parameters in Li-Ion battery packs. It also directly interfaces the Seiko S-8243 protection IC to minimize component count in smart-battery circuits. The bq2063 uses a V-to-F converter with automatic offs ...
... record of available charge in Li-Ion batteries. The bq2063 monitors capacity and other critical parameters in Li-Ion battery packs. It also directly interfaces the Seiko S-8243 protection IC to minimize component count in smart-battery circuits. The bq2063 uses a V-to-F converter with automatic offs ...
S280-70-10
... ensure that the TIE recloser will not close automatically upon restoration of voltage from one source. • In the SECTIONALIZING mode, once voltage is restored, the LS is disabled until locally or remotely enabled. The recloser remains in the same state prior to the loss of voltage. The SECTIONALIZIN ...
... ensure that the TIE recloser will not close automatically upon restoration of voltage from one source. • In the SECTIONALIZING mode, once voltage is restored, the LS is disabled until locally or remotely enabled. The recloser remains in the same state prior to the loss of voltage. The SECTIONALIZIN ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.