• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
S270-21-2 (Discontinued)
S270-21-2 (Discontinued)

... SUPPLY COUNT RESTRAINT ...
ADG3249 数据手册DataSheet 下载
ADG3249 数据手册DataSheet 下载

... Extra power supply current component for the EN control input when the input is not driven at the supplies. Data Propagation Delay through the Switch in the ON State. Propagation delay is related to the RC time constant RON × CL, where CL is the load capacitance. Bus Enable Times. These are the time ...
BDTIC www.BDTIC.com/infineon RF and Protection Devices BGB741L7ESD and BGS12AL7
BDTIC www.BDTIC.com/infineon RF and Protection Devices BGB741L7ESD and BGS12AL7

... Functional and Pinout Diagram of BGS12AL7-4 .................................................................................6 Block diagram of of TV and FM reception in mobile phone application...............................................7 Block Diagram of an application for analog and digital TV ...
Sequential Logic
Sequential Logic

... Figure 3. Voltage transfer characteristic of a latch (bistable circuit) The operating points (Q-points) for this circuit must lie on the voltage transfer curve. Furthermore the loop connection imposes that the input and output voltages must be the same. Therefore the “load line” of this circuit is a ...
User Guide
User Guide

... system cabinets Table t -, Idenll~es the racks and Ihe number ot dnves each type 01 rack IS capal)le 01 aocommo~aTlrog. ...
Intel Joule Module
Intel Joule Module

John H. Scofield, Rev. Sci. Instrum. 58
John H. Scofield, Rev. Sci. Instrum. 58

attachment=3734
attachment=3734

200307176 Isobar RM Metal Owner`s Manual 93
200307176 Isobar RM Metal Owner`s Manual 93

... No extension cords, or other electrical connections may be used. The installation must comply with all applicable electrical and safety codes set forth by the National Electrical Code (NEC). Except as provided above, this warranty does not cover any damage to properly connected electronic equipment ...
radiac set an/pdr-56f (nsn 6665-01-113-9530)
radiac set an/pdr-56f (nsn 6665-01-113-9530)

... the radiacmeter and the main, auxiliary, and x-ray probes. These items and their circuitry are laid out on the block diagram (fig. 2-1) with the direction of signal flow from left to right. The signal starts in the probe (main, auxiliary, or x-ray) and ends up as both a meter indication and a sound ...
Data Sheet
Data Sheet

... Electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
BA157, BA158, BA159D, BA159 Fast Switching Plastic Rectifier
BA157, BA158, BA159D, BA159 Fast Switching Plastic Rectifier

... Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use ...
miniature halogen lamps
miniature halogen lamps

System Manual MMS 6000 Part 7 MMS 6220 Direction for use
System Manual MMS 6000 Part 7 MMS 6220 Direction for use

Integrating Electronic Equipment and Power Into Rack Enclosures
Integrating Electronic Equipment and Power Into Rack Enclosures

... conductors or speaker wires. A hum may be induced from these wires into the signal conductors. This is especially likely in long parallel wire runs, where more separation may be required. 4) When it is necessary to install signal conductors and power conductors or speaker wires in close proximity to ...
MAX9384 ECL/PECL Dual Differential 2:1 Multiplexer General Description Features
MAX9384 ECL/PECL Dual Differential 2:1 Multiplexer General Description Features

... Bypass each VCC to VEE with high-frequency surfacemount ceramic 0.1µF and 0.01µF capacitors. Place the capacitors as close to the device as possible, with the 0.01µF capacitor closest to the device pins. Use multiple vias when connecting the bypass capacitors to ground. When using the VBB0 or VBB1 r ...
Viesturs Bražis. Asynchronous electric drive with frontal part winding
Viesturs Bražis. Asynchronous electric drive with frontal part winding

BLACK BOX ELECTRONIC FISHING TECHNOLOGY Chapter I
BLACK BOX ELECTRONIC FISHING TECHNOLOGY Chapter I

... older the downrigger wire, the more likely it is covered with scum or corrosion. It will give you a low reading even with a good zinc. For testing purposes you can scrape or clean a section of the wire with steel wool. If the wire has broken strands it's probably time to replace it. Otherwise the be ...


... In the event that the ticker mechanism P ejects the tape at a faster rate than it is drawn - vantageous. With such an arrangement, the in formation ebtained by observation of the pro by the motor M, when energized over the circuit jection screen is almost current at times because last described, the ...
Specification Guide - Rockwell Automation
Specification Guide - Rockwell Automation

... The motor protection relay shall provide current measurement-based protection functions with optional voltage measurement-based and temperature measurement-based functions. Current measurement shall be performed by a separate three-phase current converter module that provides electrical isolation be ...
NODE ANALYSIS
NODE ANALYSIS

Ten-Tec 1254 Manual
Ten-Tec 1254 Manual

... 455 kHz second IF 4 kHz filter bandwidth combines good AM audio response with excellent SSB-CW selectivity Semiconductors: 10 IC 's, 26 transistors, 16 diodes Antenna connector can supply DC voltage for active antenna 1.5W audio output, built-in speaker, headphone jack Includes a wall-ty ...
- Legrand
- Legrand

... limit is 50 V (conventional limit value) but lower supply voltage values of 25 V or 12 V are used for operating conditions in damp or submerged environments� If the extra low voltage is not provided by a safety source (auto-transformers, electronic power supply, variable control unit), the circuit c ...
Chapter 4 - Mathematics for Amateur Radio
Chapter 4 - Mathematics for Amateur Radio

... calculation as part of their hobby. This is true whether they are calculating an antenna length or designing a new piece of station equipment. When they do, they will be using mathematics. The math skills required for most electronics calculations can be developed and used by just about anyone. This ...
USB 2.0 and USB 3.0 Circuit Protection
USB 2.0 and USB 3.0 Circuit Protection

< 1 ... 187 188 189 190 191 192 193 194 195 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report