CO21579585
... Three-Phase four-wire distribution systems are facing severe power quality problems such as poor voltage regulation, high reactive power and harmonics current burden, load unbalancing, excessive neutral current, etc.This creates excessive neutral current both of fundamental and harmonic frequency an ...
... Three-Phase four-wire distribution systems are facing severe power quality problems such as poor voltage regulation, high reactive power and harmonics current burden, load unbalancing, excessive neutral current, etc.This creates excessive neutral current both of fundamental and harmonic frequency an ...
Action PAK AP7380 ® Frequency Input, Field Configurable
... mount, DIN rail mount or snap track mounting sockets. Trouble shooting is very easy since no wires need to be removed when swapping units. The wide ranging power supply can be configured for either 120 or 240VAC power. Application The AP7380 field configurable, frequency input signal conditioner is ...
... mount, DIN rail mount or snap track mounting sockets. Trouble shooting is very easy since no wires need to be removed when swapping units. The wide ranging power supply can be configured for either 120 or 240VAC power. Application The AP7380 field configurable, frequency input signal conditioner is ...
(AN-7) A Simple Current-Sense Technique Eliminating
... monitoring the output voltage are also used in OCP, those two techniques have very poor accuracy and are good only for output short-circuit protection. They can not protect the power supply when there is a weak short circuit at the output or the output is over current. This application note introduc ...
... monitoring the output voltage are also used in OCP, those two techniques have very poor accuracy and are good only for output short-circuit protection. They can not protect the power supply when there is a weak short circuit at the output or the output is over current. This application note introduc ...
download
... style lighting (L-866). A single beacon provides 360° coverage for structures up to 350 feet. Three beacons provide proper marking for structures between 350 and 500 feet high. The beacon is also available in 60Hz or 50Hz power options. Power consumption is 90% less than conventional incandescent be ...
... style lighting (L-866). A single beacon provides 360° coverage for structures up to 350 feet. Three beacons provide proper marking for structures between 350 and 500 feet high. The beacon is also available in 60Hz or 50Hz power options. Power consumption is 90% less than conventional incandescent be ...
Chapter 19 - Electricity
... resistance of 500,000 Ohms, and about 1000 Ohms when wet (water is a good conductor). Safety Paul says "Don't play with the toaster in the bath tub") Touching a 120 V outlet gives you a shock, but not enough to kill you because your resistance is high. Using Ohm's Law: Current = Volts / Resistance, ...
... resistance of 500,000 Ohms, and about 1000 Ohms when wet (water is a good conductor). Safety Paul says "Don't play with the toaster in the bath tub") Touching a 120 V outlet gives you a shock, but not enough to kill you because your resistance is high. Using Ohm's Law: Current = Volts / Resistance, ...
File
... Up to this stage in your study of physics we have assumed that power supplies are ideal. This means that their voltage remains constant and they can supply any current we wish if we connect the correct resistance. In most cases these are good assumptions, but if you take a small battery and connect ...
... Up to this stage in your study of physics we have assumed that power supplies are ideal. This means that their voltage remains constant and they can supply any current we wish if we connect the correct resistance. In most cases these are good assumptions, but if you take a small battery and connect ...
If we can drop the voltage and frequency, then we... (write 0->read 1; the value of the write should appear...
... networked applications are leading to the widespread adoption of 802.11n, the latest version of the standard. In batteryoperated devices such as mobile phones, radio interfaces can account for a significant portion of total power budget. There is little data available to help designers operate 802.1 ...
... networked applications are leading to the widespread adoption of 802.11n, the latest version of the standard. In batteryoperated devices such as mobile phones, radio interfaces can account for a significant portion of total power budget. There is little data available to help designers operate 802.1 ...
To Pot or Not Two common types of electrical testing are easily
... strength of insulation, its ability to withstand voltage stress, rather than with its measurement. Some high‐pots do indeed include meters that indicate current or resistance, but these are ancillary functions. The purpose of the tester is to break down marginal insulation ...
... strength of insulation, its ability to withstand voltage stress, rather than with its measurement. Some high‐pots do indeed include meters that indicate current or resistance, but these are ancillary functions. The purpose of the tester is to break down marginal insulation ...
Using a multimeter to take measurements - SBSZ Jena
... semiconductor materials that are highly sensitive to changes in temperature. This property of thermistors has many important applications such as the measurement and control of temperature, for example in fire alarms. Thermistors can have a negative or a positive temperature coefficient. So there ar ...
... semiconductor materials that are highly sensitive to changes in temperature. This property of thermistors has many important applications such as the measurement and control of temperature, for example in fire alarms. Thermistors can have a negative or a positive temperature coefficient. So there ar ...
The letters LVDT are an acronym for Linear Variable
... In operation, the LVDT's primary winding is energized by alternating current of appropriate amplitude and frequency, known as the primary excitation. The LVDT's electrical output signal is the differential AC voltage between the two secondary windings, which varies with the axial position of the cor ...
... In operation, the LVDT's primary winding is energized by alternating current of appropriate amplitude and frequency, known as the primary excitation. The LVDT's electrical output signal is the differential AC voltage between the two secondary windings, which varies with the axial position of the cor ...
Texas Instruments
... The maximum power dissipation is a function of TJ(max), θJA, and TA. The maximum allowable power dissipation at any ambient temperature is PD = (TJ(max) − TA)/θJA. If this dissipation is exceeded, the die temperature will rise above 150°C and the LM2941 will go into thermal shutdown. If the TO-263 p ...
... The maximum power dissipation is a function of TJ(max), θJA, and TA. The maximum allowable power dissipation at any ambient temperature is PD = (TJ(max) − TA)/θJA. If this dissipation is exceeded, the die temperature will rise above 150°C and the LM2941 will go into thermal shutdown. If the TO-263 p ...
R-Electric-Circuits-Unit
... Once a circuit is switched on, the current and potential difference are experienced almost instantaneously in all parts of the circuit even though the electrons are only moving at speeds of a few centimeters per hour in a current-carrying wire. It is the electric field that travels instantaneously t ...
... Once a circuit is switched on, the current and potential difference are experienced almost instantaneously in all parts of the circuit even though the electrons are only moving at speeds of a few centimeters per hour in a current-carrying wire. It is the electric field that travels instantaneously t ...
Wireless networking kit Datasheet
... Utilising a LAN (local area network) connection and an internet browser enabled device to remotely set up an Ampetronic networkable driver via the network control panel makes Hearing Loop system testing or commissioning a much quicker and efficient process. The driver settings can be controlled and ...
... Utilising a LAN (local area network) connection and an internet browser enabled device to remotely set up an Ampetronic networkable driver via the network control panel makes Hearing Loop system testing or commissioning a much quicker and efficient process. The driver settings can be controlled and ...
XGE fan speed controls
... quality control procedures ensure trouble free operation for many years. For example, prevention of overheating is extremely important in such compact controllers, and a specially designed heat dissipation radiator is placed on the side of the controller, ensuring no overheating and a longer product ...
... quality control procedures ensure trouble free operation for many years. For example, prevention of overheating is extremely important in such compact controllers, and a specially designed heat dissipation radiator is placed on the side of the controller, ensuring no overheating and a longer product ...
低功耗、精密 单电源运算放大器 OPA2234M 特性
... Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been de ...
... Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been de ...
Using Thyristors in Heating Applications
... Thyristors and solid state relays dissipate heat when conducting. The power dissipated is approximately 1.5 to 2 x (RMS current) x (Number of Controlled Lines). This power loss can cause a significant temperature rise in the control panel, and it is important to ensure that the maximum ambient tempe ...
... Thyristors and solid state relays dissipate heat when conducting. The power dissipated is approximately 1.5 to 2 x (RMS current) x (Number of Controlled Lines). This power loss can cause a significant temperature rise in the control panel, and it is important to ensure that the maximum ambient tempe ...
exoLighttm
... • No ballast or starter needed • No EMI/RFI • No UV emissions lens or diffuser aging • Long-life diffused cool LED light (up to 100,000 hrs) • Perfect for low cost machine vision lighting and other applications • Patented and patent pending technologies • Safe: power options straight 24VDC or AC/DC ...
... • No ballast or starter needed • No EMI/RFI • No UV emissions lens or diffuser aging • Long-life diffused cool LED light (up to 100,000 hrs) • Perfect for low cost machine vision lighting and other applications • Patented and patent pending technologies • Safe: power options straight 24VDC or AC/DC ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.