• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
DND5057 - pes-psrc
DND5057 - pes-psrc

... Three-line diagram (ac). A diagram that represents a group of three-phase power system elements with three lines (or four, including neutral) interconnecting the elements. See: one-line diagram. Time code stamping. Associating an accurate time with a particular event. Transient overreach. A tendency ...
as a PDF
as a PDF

... Figure 5 shows the block diagram of a typical MPPT converter. The MPPT control varies the duty cycle of the DC/DC converter using a PWM signal. The MPPT algorithm is based on the variation of the duty cycle of the DC/DC converter in response to changing input parameters (I and V and therefore the po ...
datasheet for the QRD1114
datasheet for the QRD1114

... PACKAGE DIMENSIONS ...
Question Syllabus reference Question Marks 1 Marking guide
Question Syllabus reference Question Marks 1 Marking guide

... magnetic field, which would attract the lever closing the contact. b) i) Autotransformer. ii) An autotransformer has not got independent primary and secondary windings, whereas a double wound type has. iii) The tapped connections cater for the selection of various secondary output voltages. ...
Application Note
Application Note

Neon Sign Transformer
Neon Sign Transformer

... Neon Signs play an important role when it comes to giving aesthetic look to an object, shop or place. But, all these neon signs require Neon Sign Transformer. These transformers are used to convert mains voltages to those suitable for powering neon signs. They are also known as Luminous Tube Transfo ...
UM0353
UM0353

... The THERM01EVAL board is designed to be a complete MCU-controlled thermostat application when used with a M2020 12k NTC thermal sensor, from EPCOS (supplied with the kit). This thermostat can be used to control a single-phase induction motor, and works with a 220240 V RMS 50 Hz mains voltage. The bo ...
a review on power system harmonics
a review on power system harmonics

... The capacitor banks are used to counter the harmonic effects up to some extent in the power system. These capacitors are designed such that it can operate at a maximum of 110% of their rated voltage and 135% of its kVAR rating. As we know that the capacitive reactance is inversely ...
STD830CP40
STD830CP40

... The STD830CP40 is a hybrid complementary pair of power bipolar transistors manufactured by using the high voltage multi-epitaxial planar technology for high switching speeds and medium voltage capability. ...
Single Port, High Output Current VDSL2 Line Driver with Power Control OPA2670 FEATURES
Single Port, High Output Current VDSL2 Line Driver with Power Control OPA2670 FEATURES

... ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more susceptible to damage because very small parametric changes could cause the device not to meet its published specifications. ...
ENEE 244 - Ece.umd.edu
ENEE 244 - Ece.umd.edu

Digital Panel Meters Modular Indicator and Controller Type UDM40
Digital Panel Meters Modular Indicator and Controller Type UDM40

... All accuracies and min/max indications are referred to an ambient temp. range of 25°C ±5°C, rel. humidity ≤60% and scale ratio (electrical/displayed scale) equal to 1. The conversion into °F is obtained acting on the electrical/displayed scale ratio. ...
lecture11
lecture11

... We have been making calculations with voltages from batteries without asking detailed questions about the batteries. Now it’s time to look inside the batteries. ...
MAX17031 Dual Quick-PWM Step-Down Controller with Low- General Description
MAX17031 Dual Quick-PWM Step-Down Controller with Low- General Description

... power-supply (SMPS) controller with synchronous rectification, intended for main 5V/3.3V power generation in battery-powered systems. Low-side MOSFET sensing provides a simple low-cost, highly efficient current sense for valley current-limit protection. Combined with the output overvoltage and under ...
LM117HV/LM317HV 3-Terminal Adjustable Regulator (Rev. D)
LM117HV/LM317HV 3-Terminal Adjustable Regulator (Rev. D)

... is situated more than 6 inches from the input filter capacitors, in which case an input bypass is needed. An optional output capacitor can be added to improve transient response. The adjustment terminal can be bypassed to achieve very high ripple rejection ratios which are difficult to achieve with ...
Ch14_PPT_Fund_Elec_Circ_5e (1)
Ch14_PPT_Fund_Elec_Circ_5e (1)

... created from a RLC circuit by taking the output from the LC series combination. • The range of blocked frequencies will be the same as the range of passed frequencies for the bandpass filter. ...
165-640-900 Protective Relays P C
165-640-900 Protective Relays P C

ADS1208 数据资料 dataSheet 下载
ADS1208 数据资料 dataSheet 下载

... This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with appropriate precautions. Failure to observe proper handling and installation procedures can cause damage. ESD damage can range from subtle performance degradation to complete devi ...
A closer look at VSD voltage output waveforms
A closer look at VSD voltage output waveforms

... microseconds at the VSD terminals (before the dv/dt filter) and 5,0 microseconds at the motor terminals (after the dv/dt filter). Five microseconds is a long time for IGBT VSDs and it falls well within most motor manufacturers’ guidelines for motor terminal voltage rise-time. The voltage measurement ...
EET 161 02
EET 161 02

... COMPONENTS: Students are asked to purchase 3 sets of leads, needle nose pliers, and wire strippers. These are available through the bookstore (BASIC TOOL KIT), or from other local vendors. CALCULATOR: a TI 84 or 86 or 89 or equivalent calculator is required for this class. COURSE DESCRIPTION: The fi ...
DAC8811 - Texas Instruments
DAC8811 - Texas Instruments

... The DAC8811 multiplying digital-to-analog converter (DAC) is designed to operate from a single 2.7-V to 5.5-V supply. The applied external reference input voltage VREF determines the full-scale output current. An internal feedback resistor (RFB) provides temperature tracking for the full-scale outpu ...
AD667 数据手册DataSheet 下载
AD667 数据手册DataSheet 下载

... AD667 results from a combination of advanced switch design, high speed bipolar manufacturing process, and the proven laser wafer-trimming (LWT) technology. The AD667 is trimmed at the wafer level and is specified to ± 1/4 LSB maximum linearity error (K, B grades) at +25°C and ± 1/2 LSB over the full ...
MAX15059 76V, 300mW Boost Converter and Current Monitor for APD Bias Applications
MAX15059 76V, 300mW Boost Converter and Current Monitor for APD Bias Applications

... Junction-to-Ambient Thermal Resistance (qJA)...........48°C/W Junction-to-Case Thermal Resistance (qJC)..................7°C/W Note 1: Package thermal resistances were obtained using the method described in JEDEC specification JESD51-7, using a fourlayer board. For detailed information on package t ...
Aalborg Universitet
Aalborg Universitet

ULTRA SLIMPAK G128-0001 ® DC Powered T/C Input Limit Alarm
ULTRA SLIMPAK G128-0001 ® DC Powered T/C Input Limit Alarm

... below the HI deadband or rises above the LO deadband (see Figure 1). For proper deadband operation, the HI setpoint must always be set above the LO setpoint. In failsafe operation, the relay is energized when the process is below the HI setpoint or above the LO setpoint (opposite for non-failsafe). ...
< 1 ... 1573 1574 1575 1576 1577 1578 1579 1580 1581 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.