• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
LT1513/LT1513-2 - Linear Technology
LT1513/LT1513-2 - Linear Technology

... circuitry and switch current. VC, FB and S/S signals must be Kelvin and connected as close as possible to this pin. The TAB of the R package should also be connected to the power ground. VSW (Pin 5): The switch pin is the collector of the power switch, carrying up to 3A of current with fast rise and ...
Agilent 33220A Function Generator Tutorial
Agilent 33220A Function Generator Tutorial

... frequency at which repeated pulses are sent. • Ampl: Amplitude (peak-to-peak), defined as the distance between the highest and lowest voltage points of a waveform. • Offset: DC voltage offset. The time-varying waveform is offseted (“raised”) by the constant offset component (e.g. if you want a sinus ...
MICROGRID COMPATIBILITY OF PHOTOVOLTAIC AND WIND POWER SYSTEMS
MICROGRID COMPATIBILITY OF PHOTOVOLTAIC AND WIND POWER SYSTEMS

... The fixed speed generators have a design speed for which they have maximum efficiency whereas for other speeds their efficiency is lower. Variable speed generators have the maximum power tracking capability that extracts maximum available power out of the wind at different speeds thereby resulting i ...
Sunny Boy Storage 2.5
Sunny Boy Storage 2.5

... Systems with the Sunny Boy Storage can be flexibly adapted to individual needs at any time. Whether the family situation changes, perhaps with the purchase of an electric car, which needs charging daily, or with a swimming pool in the garden for pleasure—with the Sunny Boy Storage, storage systems a ...
RESISTORS FOR LIGHTING APPLICATIONS
RESISTORS FOR LIGHTING APPLICATIONS

What are the 555 timer applications?
What are the 555 timer applications?

... connected internally, and TR falling edge sensitive instead of level sensitive). ...
LM1577/LM2577 SIMPLE SWITCHER Step-Up
LM1577/LM2577 SIMPLE SWITCHER Step-Up

... components, these regulators are cost effective, and simple to use. Listed in this data sheet are a family of standard inductors and flyback transformers designed to work with these switching regulators. Included on the chip is a 3.0A NPN switch and its associated protection circuitry, consisting of ...
O A
O A

... load power and KVA is the apparent load power, it is a measure of how effectively the current is being converted into useful work output and more particularly is a good indicator of the affect of load current on the efficiency of the supply system current will cause losses in the supply and distribu ...
Stresa, Italy, 26-28 April 2006  IMEC, Kapeldreef 75, 3001 Leuven, Belgium
Stresa, Italy, 26-28 April 2006 IMEC, Kapeldreef 75, 3001 Leuven, Belgium

... originates from a variety of situations, ranging from vibrations of rotating engines to the movement of machine parts. The source of energy that will be used depends strongly on the application, which might be a very small and lightweight sensor, with low power but high mobility requirements, or cou ...
DYNAMO AND REGULATOR Most /2 BMW`s are equiped with a 6
DYNAMO AND REGULATOR Most /2 BMW`s are equiped with a 6

... drop the revs. The current from the battery to the dynamo will rise to 2.5-9.0 Amp, and then suddenly drops to zero, indicating that the circuit breaker has opened. This all sounds nice and simple, but there are some caveats. In fact this whole setup is one big compromise to get the best results in ...
INTRODUCTION TO T&T WIRING CODE
INTRODUCTION TO T&T WIRING CODE

... enclosed or flameproof type, be installed at a minimum height of 1200mm ( 4ft ) above the general floor level. ...
Power Quality - Portal UniMAP
Power Quality - Portal UniMAP

... Recently (in the last ten years or so), partly because of the need for lighter weight and higher efficiency, the "switched-mode" power supply was developed. The switched-mode power supply has a full-wave bridge rectifier (BR1 in diagram) directly connected to the incoming 120 V AC line. The switchin ...
NTD_Final_Ch3-3_3-4 DOWNLOAD
NTD_Final_Ch3-3_3-4 DOWNLOAD

... Fig. 9. An equivalent circuit diagram of the SCR and its operation. When the gate signal is applied to the gate terminal of SCR, VGT is 0 before t1, thus, IB2= 0. IC2, the base current of Q1 is about ICO. This current is too small to make Q1 an on state. Therefore, two transistors are all off state, ...
Reigh Walling Commen.. - pes-psrc
Reigh Walling Commen.. - pes-psrc

... In addition to the various currents and voltages to be provided for the various faults at the indicated locations for the indicated cases, also indicate if there is a threshold voltage at the point of interconnection at which the fault current contribution changes suddenly, for instance if a crowbar ...
(a) Results based on the measurements on the circuit in Figure 3(a)
(a) Results based on the measurements on the circuit in Figure 3(a)

... source alone, and the current I2 due to the 2A current source alone, and then taking the sum of I1 and I2. For a more complicated circuit, the effect of each individual source can be determined one at a time by turning off all the other sources. In calculation in superposition theorem, a voltage sou ...
- V
- V

... • Work on electrical panels with one hand in your pocket, standing on insulated platforms to avoid any return path for current • Three-prong plugs • Provide a separate current path, usually connected to a metal case of an appliance, in case of a short between the “hot” wire and the case ...
View Book Sample
View Book Sample

FR011L5J (11mΩ, -30V) Low-Side Reverse Bias / Reverse Polarity Protector FR011L
FR011L5J (11mΩ, -30V) Low-Side Reverse Bias / Reverse Polarity Protector FR011L

... qualification devices, where the predicted failure rate is less than 0.01% at the specified voltage for 24 hours. It is intended to indicate the device’s ability to withstand transient events that exceed the recommended operating voltage rating. Specification is based on qualification devices tested ...
A75D / A75DE SCR BATTERY CHARGER Digital METERS THREE
A75D / A75DE SCR BATTERY CHARGER Digital METERS THREE

... See Wire Size Chart, lists the ac input and dc output minimum wire size requirements. At distances exceeding 10 feet, the dc wire size should be chosen to keep the voltage difference between the units dc output terminals and the battery at less that ½ volt when the unit is fully loaded. See the sect ...
OPA4872-EP 数据资料 dataSheet 下载
OPA4872-EP 数据资料 dataSheet 下载

... switching glitch is improved over earlier solutions using a new (patented) input stage switching approach. This technique uses current steering as the input switch while maintaining an overall closed-loop design. The OPA4872 exhibits an off isolation of 88dB in either Disable or Shutdown mode. With ...
Discontinuous conduction/current mode analysis of dual interleaved
Discontinuous conduction/current mode analysis of dual interleaved

LM35 - Techno e
LM35 - Techno e

... The LM35 series are precision integrated-circuit temperature sensors, whose output voltage is linearly proportional to the Celsius (Centigrade) temperature. The LM35 thus has an advantage over linear temperature sensors calibrated in ˚ Kelvin, as the user is not required to subtract a large constant ...
Evaluates: MAX17620 MAX17620 Evaluation Kit
Evaluates: MAX17620 MAX17620 Evaluation Kit

NODE ANALYSIS
NODE ANALYSIS

... NODAL AND LOOP ANALYSIS TECHNIQUES LEARNING GOALS NODAL ANALYSIS LOOP ANALYSIS ...
Chapter 4
Chapter 4

... Output from line is not instantaneous vp = 1/(LC)1/2 Input appears to be a resistance (top figure) Load terminated by MOSFET (high resistance) ...
< 1 ... 1575 1576 1577 1578 1579 1580 1581 1582 1583 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report