• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Analysis of a Novel Soft Switching Bidirectional DC-DC
Analysis of a Novel Soft Switching Bidirectional DC-DC

... In the case of conventional bidirectional DC-DC converter, the main switches operate under hard switching [11][15-16] condition in boost mode and buck mode. Since this switching loss is one of serious dissipation, it is able to be caused to drop the efficiency of system. General method to prevent ef ...
Tech Note 4/16 Meg-alert VFD and Solid State Soft Starter
Tech Note 4/16 Meg-alert VFD and Solid State Soft Starter

FT7522 Reset Timer with Fixed Delay and Reset Pulse
FT7522 Reset Timer with Fixed Delay and Reset Pulse

... Device default operation time N is 7.5s. If the DSR pin is pulled HIGH prior to VCC ramp, the FT7522 enters Test Mode and the reset output, /RST1, is immediately pulled LOW for factory testing. The DSR pin MUST be forced to GND during normal operation. The DSR pin should never be driven HIGH or lef ...
Electrical Distribution Products for Commercial and Industrial Applications
Electrical Distribution Products for Commercial and Industrial Applications

... transformers to 14,000 kVA. Our transformers have earned a worldwide reputation for quality and reliability. The Indoor Powercenter™ Transformer offers improved safety, reliability and efficiency, and has a lower cost than a dry-type transformer. It’s specially designed and approved for all indoor o ...
Dual, Bootstrapped, 12 V MOSFET Driver with Output Disable ADP3650
Dual, Bootstrapped, 12 V MOSFET Driver with Output Disable ADP3650

... Upper MOSFET Floating Bootstrap Supply. A capacitor connected between the BST and SW pins holds this bootstrapped voltage for the high-side MOSFET while it is switching. Logic Level PWM Input. This pin has primary control of the drive outputs. In normal operation, pulling this pin low turns on the l ...
Accidents in home and environment
Accidents in home and environment

... • Flash burns – typically superficial • Contact burns – may be negligible surface burning but deeper tissue damage due to the conduction of electricity through tissue plains. These burns can be further divided into high tension or voltage and low tension/ voltage burns. • Electrical conduction throu ...
abworks Inc. L - Labworks Inc.
abworks Inc. L - Labworks Inc.

... 2950 airway ave., a-16, costa mesa, ca 92626 • (714) 549-1981 • fax (714) 549-8041 ...
Heavy-Duty Truck Sytems Chapter 06
Heavy-Duty Truck Sytems Chapter 06

... producing an outcome based on the switching status of components in the gate circuit. • The binary numeric system is a two-digit arithmetic system that is often used in computer electronics because it directly corresponds to the on or off states of switches and circuits. • A bit is the smallest piec ...
A DC27-2 Maxstar 150 STH.qxd
A DC27-2 Maxstar 150 STH.qxd

application of resonant converter in ozone generator
application of resonant converter in ozone generator

... The output of common inverter is square wave, which convert from DC source to AC. This energy will be fed into ozone chamber model 2.a, by variation of voltage and frequency. The simplification model of resonant circuit is depictured in Figure 3. To obtain high voltage the out put of inverter is fed ...
SMJE-XV08W2P4 - Seoul Semiconductor
SMJE-XV08W2P4 - Seoul Semiconductor

A CMOS Fully-Integrated Wireless Power Receiver for Autonomous
A CMOS Fully-Integrated Wireless Power Receiver for Autonomous

... operating at 1 GHz, was reported in [5], nevertheless the inductors are out of the chip. The efficiency of the 3-stage rectifier was 65%, however, the losses on the matching network were not taken into account. A rectifier presenting 86% of efficiency was brought in [6]. Nonetheless, they designed a ...
Efficiency
Efficiency

... transformers. It is called ’all day’ efficiency. The all day efficiency is thus the ratio of the energy output of the transformer over a day to the corresponding energy input. One day is taken as a duration of time over which the load pattern repeats itself. This assumption, however, is far from bei ...
NTB75N03R, NTP75N03R Power MOSFET 75 Amps, 25 Volts N
NTB75N03R, NTP75N03R Power MOSFET 75 Amps, 25 Volts N

SiT1533 - SiTime
SiT1533 - SiTime

... DC-coupled applications, output VOH and VOL are individually fctory programmed to the customers’ requirement. VOH programming range is between 600 mV and 1.225V in 100 mV increments. Similarly, VOL programming range is between 350 mV and 800 mV. For example; a PMIC or MCU is internally 1.8V logic co ...
WIR-TRAN - S.R. Smith
WIR-TRAN - S.R. Smith

... conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by S.R. Smith could void the user's authority to operate the equipm ...
the electric warship then, now and later
the electric warship then, now and later

... which at one stage represented over 80% of the world funding for power electronic devices, allowed incremental device improvements and enabled IGBT based power conversion to exceed the requirement of an electric warship. Hence these technologies were not adopted or even fully developed because they ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

ADM1085 数据手册DataSheet 下载
ADM1085 数据手册DataSheet 下载

... Similarly, if the enable input is disabled while VIN is above the threshold, the enable output deasserts immediately. Unlike VIN, a low-to-high transition on ENIN (or high-to-low on ENIN) does not yield a time delay on ENOUT (ENOUT). ...
parallel circuit +
parallel circuit +

... Here is a diagram of Susan's flashlight. Explain how the concepts voltage, current, power, and energy are involved in this device; by the time you are done, you should have completely explained the sentence, " It gives off three times as much light, but the batteries don't last very long. " ...
user guide - KRK Systems
user guide - KRK Systems

... The close-field monitor, by definition, reduces room interaction. This can be compared to the conventional stereo configuration or the large monitor arrangement in a recording studio where sounds emanating from the monitor or reflecting off ceilings, walls, and floors greatly affect the sound qualit ...
3 1/2 Digit, LCD/LED Display, A/D Converters
3 1/2 Digit, LCD/LED Display, A/D Converters

... The reference voltage can be generated anywhere within the power supply voltage of the converter. The main source of common mode error is a roll-over voltage caused by the reference capacitor losing or gaining charge to stray capacity on its nodes. If there is a large common mode voltage, the refere ...
Passive Active - Drammen Lyd AS
Passive Active - Drammen Lyd AS

... suited to passive direct boxes. A high performance passive DI like the JDI™ Stereo not only handles these high output instruments with grace, but when pushed hard, the Jensen transformers smooth out the transient response. For low level signals such as a passive bass, magnetic acoustic guitar pickup ...
Solutions 20.37-20.51 - UF Physics
Solutions 20.37-20.51 - UF Physics

... 43. Unfortunately, this problem is worded differently in different printings of the book. My book says “How much power is lost in a resistor when a 3.0-V battery sends a current of 0.30 A through it?” The problem is a very simple one. The power is given by P = IV. P = (0.30 A)(3.0 V) = 0.90 watts. ...


... fellowship by Japan Society for the Promotion of Science (JSPS). As a postdoctoral fellow, he worked on power system monitoring by application of GPS synchronized by phasor measurement units (PMUs) in the Department of Electrical Engineering at the Kyushu Institute of Technology, Japan. From 2005-20 ...
< 1 ... 1369 1370 1371 1372 1373 1374 1375 1376 1377 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.