ISL9R30120G2 30 A, 1200 V STEALTH™ Diode ISL9R30120G2 — STEALTH™ Diode
... low loss performance in high frequency hard switched applications. The STEALTH™ family exhibits low reverse recovery current (IRR) and exceptionally soft recovery under typical operating conditions. This device is intended for use as a free wheeling or boost diode in power supplies and other power s ...
... low loss performance in high frequency hard switched applications. The STEALTH™ family exhibits low reverse recovery current (IRR) and exceptionally soft recovery under typical operating conditions. This device is intended for use as a free wheeling or boost diode in power supplies and other power s ...
Data Sheet V2.0 2014-01-20 CoolSET™ F3R80 ICE3AR1080VJZ
... Characteristics ............................................................................................................................. 31 ...
... Characteristics ............................................................................................................................. 31 ...
Build a 2-Stage Power Attenuator for Your High Powered Tube Amp
... the power by -6db. It makes no difference which switch is flipped on first. You can use either one or both to go from true bypass to -6db to -12db. I would not recommend making a third stage because when you attenuate more than -15db, attenuation will begin to affect the tone. Attenuation with this ...
... the power by -6db. It makes no difference which switch is flipped on first. You can use either one or both to go from true bypass to -6db to -12db. I would not recommend making a third stage because when you attenuate more than -15db, attenuation will begin to affect the tone. Attenuation with this ...
TWTs Still Drive High-Power Systems
... MPMs are highly regarded not just for active electronically steered array (AESA) radar applications, but in synthetic aperture radar (SAR) systems in which long pulse widths are required, EW and ECM suites, and commercial and military satellite communications systems. dB Control MPMs are used in ...
... MPMs are highly regarded not just for active electronically steered array (AESA) radar applications, but in synthetic aperture radar (SAR) systems in which long pulse widths are required, EW and ECM suites, and commercial and military satellite communications systems. dB Control MPMs are used in ...
JFET-Input Operational Amplifier (Rev. C)
... TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information published by TI ...
... TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information published by TI ...
Model Based-Energy Control of a Solar Power Plant With a
... Recent breakthroughs in construction methods aimed at maximizing rated capacitance have provided tremendous increases in the energy-storage capabilities of the double-layer capacitor [27]. With a time constant (the product of equivalent series resistance (ESR) and capacitance) of 0.001–2 s for an SC ...
... Recent breakthroughs in construction methods aimed at maximizing rated capacitance have provided tremendous increases in the energy-storage capabilities of the double-layer capacitor [27]. With a time constant (the product of equivalent series resistance (ESR) and capacitance) of 0.001–2 s for an SC ...
Lab 1 - La Salle University
... 10. Right click on the voltmeter. Choose Properties. Make sure the voltmeter is in DC mode. 11. Click the Activate simulation button which is often on the upper right, but is on the left in the picture below because the tools wrapped around. Read the voltage across R1 off of the voltmeter. Enter it ...
... 10. Right click on the voltmeter. Choose Properties. Make sure the voltmeter is in DC mode. 11. Click the Activate simulation button which is often on the upper right, but is on the left in the picture below because the tools wrapped around. Read the voltage across R1 off of the voltmeter. Enter it ...
Foot-switch wiring for Guitar Pedals
... switching? Well, it pretty much bones it, but you can at least keep the grounding intact in case of a switch failure. Just add one extra wire between lugs 2 and 3 of SW1A. The wire means the grounds stay connected even if our switch fails. PS I learned this trick from Marc Skreddy. fig.13 ...
... switching? Well, it pretty much bones it, but you can at least keep the grounding intact in case of a switch failure. Just add one extra wire between lugs 2 and 3 of SW1A. The wire means the grounds stay connected even if our switch fails. PS I learned this trick from Marc Skreddy. fig.13 ...
Effects of Total Harmonic Distortion on Power System
... Harmonics, which is central focus of this study, is a specific type of disturbance that affects the quality of power, often cause by type of load attached to the power supply. It is a series of subsidiary waveforms that that accompany a primary or fundamental waveform. They result when a system prod ...
... Harmonics, which is central focus of this study, is a specific type of disturbance that affects the quality of power, often cause by type of load attached to the power supply. It is a series of subsidiary waveforms that that accompany a primary or fundamental waveform. They result when a system prod ...
Varistors MLA Automotive Datasheet
... suppression devices is based on the Littelfuse Multilayer fabrication technology. These components are designed to suppress a variety of transient events, including those specified in IEC 61000-4-2 or other standards used for Electromagnetic Compliance (EMC). The MLA Automotive Series is typically a ...
... suppression devices is based on the Littelfuse Multilayer fabrication technology. These components are designed to suppress a variety of transient events, including those specified in IEC 61000-4-2 or other standards used for Electromagnetic Compliance (EMC). The MLA Automotive Series is typically a ...
PDF
... the two curves are due to thermal gradients in the microring caused by the integrated heater, a problem that can be alleviated with greater thermal isolation of the microring. Furthermore the position of the ring resonance due to thermal drift is also related to the sensor voltage in a linear fashio ...
... the two curves are due to thermal gradients in the microring caused by the integrated heater, a problem that can be alleviated with greater thermal isolation of the microring. Furthermore the position of the ring resonance due to thermal drift is also related to the sensor voltage in a linear fashio ...
Smart sensor II dual-channel 1-bit, 4 MHz, second-order sigma
... STPMS2L-PUR: less than 0.5% error over 1:5000 range Precision voltage reference: 1.23 V with programmable TC Internal low drop regulator @ 3 V (typ.) ...
... STPMS2L-PUR: less than 0.5% error over 1:5000 range Precision voltage reference: 1.23 V with programmable TC Internal low drop regulator @ 3 V (typ.) ...
APD 7580 - Absolute Process Instruments
... optically isolated DC voltage or current output that is linearly related to the input. Common applications include frequency to DC conversions from frequency output type devices such as rotary encoders, magnetic pick-ups, proximity sensors, variable speed drives, and flow meters. For PLCs that do no ...
... optically isolated DC voltage or current output that is linearly related to the input. Common applications include frequency to DC conversions from frequency output type devices such as rotary encoders, magnetic pick-ups, proximity sensors, variable speed drives, and flow meters. For PLCs that do no ...
D12E12Safety1\4Curr\emet
... conductors or insulators 7.1.6 To explain a semiconductors crystal at some temperature above absolute zero there will be: 7.1.6.1 some level of internal energy due to the normal molecular motions (vibrations) within the crystal lattice and acting as charge carriers 7.2 To Explain “Intrinsic Conducti ...
... conductors or insulators 7.1.6 To explain a semiconductors crystal at some temperature above absolute zero there will be: 7.1.6.1 some level of internal energy due to the normal molecular motions (vibrations) within the crystal lattice and acting as charge carriers 7.2 To Explain “Intrinsic Conducti ...
Evaluates: MAX6948B MAX6948 Evaluation Kit General Description Features
... The MAX6948 EV kit GUI has a WRITE and READ button for each register. The AutoWrite checkbox can be checked to have the software automatically perform write and read operations. This feature allows the user to change states without pressing the WRITE and READ buttons. By default, AutoWrite is enable ...
... The MAX6948 EV kit GUI has a WRITE and READ button for each register. The AutoWrite checkbox can be checked to have the software automatically perform write and read operations. This feature allows the user to change states without pressing the WRITE and READ buttons. By default, AutoWrite is enable ...
NCL30060 - ON Semiconductor
... The NCL30060 integrates a 700 V startup regulator eliminating the need of external startup components. The startup regulator consists of a constant current source that supplies current from the high voltage input terminal (HV) to the supply capacitor on the VCC pin (CCC). The startup circuit current ...
... The NCL30060 integrates a 700 V startup regulator eliminating the need of external startup components. The startup regulator consists of a constant current source that supplies current from the high voltage input terminal (HV) to the supply capacitor on the VCC pin (CCC). The startup circuit current ...
Download Industrial Shock-Block Datasheet
... used on 600 V systems. These improvements to the standard Class A GFCI (6 mA trip level used on 240 V systems or less) were made to allow the use of GFCIs in industrial facilities. Equipment Ground-Fault Protective Device (EGFPD) ISB is also available with adjustable protection settings as an EGFPD. ...
... used on 600 V systems. These improvements to the standard Class A GFCI (6 mA trip level used on 240 V systems or less) were made to allow the use of GFCIs in industrial facilities. Equipment Ground-Fault Protective Device (EGFPD) ISB is also available with adjustable protection settings as an EGFPD. ...
User`s Guide Extech EX810 1000 Amp Clamp Meter with IR
... batteries and accumulators; disposal in the household garbage is prohibited! You can hand over your used batteries / accumulators at collection points in your community or wherever batteries / accumulators are sold! Disposal: Follow the valid legal stipulations in respect of the disposal of the devi ...
... batteries and accumulators; disposal in the household garbage is prohibited! You can hand over your used batteries / accumulators at collection points in your community or wherever batteries / accumulators are sold! Disposal: Follow the valid legal stipulations in respect of the disposal of the devi ...
Buck converter
A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.