MAX9384 ECL/PECL Dual Differential 2:1 Multiplexer General Description Features
... Bypass each VCC to VEE with high-frequency surfacemount ceramic 0.1µF and 0.01µF capacitors. Place the capacitors as close to the device as possible, with the 0.01µF capacitor closest to the device pins. Use multiple vias when connecting the bypass capacitors to ground. When using the VBB0 or VBB1 r ...
... Bypass each VCC to VEE with high-frequency surfacemount ceramic 0.1µF and 0.01µF capacitors. Place the capacitors as close to the device as possible, with the 0.01µF capacitor closest to the device pins. Use multiple vias when connecting the bypass capacitors to ground. When using the VBB0 or VBB1 r ...
LTM9012 - Quad 14-Bit, 125Msps ADC with Integrated Drivers
... Note 7: Integral nonlinearity is defined as the deviation of a code from a best fit straight line to the transfer curve. The deviation is measured from the center of the quantization band. Note 8: Offset error is the offset voltage measured from –0.5 LSB when the output code flickers between 00 0000 ...
... Note 7: Integral nonlinearity is defined as the deviation of a code from a best fit straight line to the transfer curve. The deviation is measured from the center of the quantization band. Note 8: Offset error is the offset voltage measured from –0.5 LSB when the output code flickers between 00 0000 ...
Outboard Systems
... block. Under normal conditions the resistance between these connections will be zero and the voltage drop will be zero. After some time in the elements corrosoin develops which increases the reisistance between the two mating surfaces. This new resistance means the applied voltage must now push its ...
... block. Under normal conditions the resistance between these connections will be zero and the voltage drop will be zero. After some time in the elements corrosoin develops which increases the reisistance between the two mating surfaces. This new resistance means the applied voltage must now push its ...
Advant OCS with Master software S800 I/O Product Guide
... A range of I/O modules is available covering analog and digital signals of various types, and interfaces for RTDs and TCs of various types. The S800 I/O system provides I/O modules with typically 4, 8 or 16 channels depending on type and ratings of the individual module. All I/O modules are supervis ...
... A range of I/O modules is available covering analog and digital signals of various types, and interfaces for RTDs and TCs of various types. The S800 I/O system provides I/O modules with typically 4, 8 or 16 channels depending on type and ratings of the individual module. All I/O modules are supervis ...
... the CM reduction performance of active EMI lters is improved at frequency range: 150 kHz-4 MHz, where the maximum reduction is about 20 dBuV comparing to the conventional circuit, and about 30 dBuV comparing to without any lter inserted. Again, these demonstrations conrm that the improvement of C ...
ARNSW Balun Day
... Transmission line transformers • For 50Ω 1:1 Baluns the transmission line must be 50Ω. • This can be coaxial cable or a bifilar parallel transmission line. • Two types of transmission line transformer have been shown to be efficient at HF. • The Current balun described by Guanella in professional l ...
... Transmission line transformers • For 50Ω 1:1 Baluns the transmission line must be 50Ω. • This can be coaxial cable or a bifilar parallel transmission line. • Two types of transmission line transformer have been shown to be efficient at HF. • The Current balun described by Guanella in professional l ...
installation and operators guide - Vista Professional Outdoor Lighting
... 1. Take-apart stainless steel hinges The door can be removed for greater access to wiring compartment during installation. To remove, open door and lift straight up and off of hinges. To replace, line up door hinges over pins of housing hinges and carefully push down. ...
... 1. Take-apart stainless steel hinges The door can be removed for greater access to wiring compartment during installation. To remove, open door and lift straight up and off of hinges. To replace, line up door hinges over pins of housing hinges and carefully push down. ...
Live Tank Circuit Breakers Application Guide
... opening of the breaking units, can be carried out outdoors. However, although the maintenance is relatively simple, certain switching operations (e.g. switching of small inductive currents) require rather frequent maintenance. SF6 gas circuit breakers are superior to these earlier technologies as th ...
... opening of the breaking units, can be carried out outdoors. However, although the maintenance is relatively simple, certain switching operations (e.g. switching of small inductive currents) require rather frequent maintenance. SF6 gas circuit breakers are superior to these earlier technologies as th ...
SV200 Manual1 - Columbus McKinnon
... • The drive operates on and contains high voltage that can cause electric shock resulting in personal injury or loss of life. Handle the drive with the same care and caution as all other high voltage electrical components. • Be sure to disconnect all AC input power to the drive before servicing. Loc ...
... • The drive operates on and contains high voltage that can cause electric shock resulting in personal injury or loss of life. Handle the drive with the same care and caution as all other high voltage electrical components. • Be sure to disconnect all AC input power to the drive before servicing. Loc ...
PAR 36 PAR 56 PAR 64 LED PAR user manual
... indicates a possible dangerous situation that can result in material and environmental damage if it is not avoided. ...
... indicates a possible dangerous situation that can result in material and environmental damage if it is not avoided. ...
V DS
... Difference in work-function between gate and substrate material, oxide thickness, Fermi voltage, charge of impurities trapped at the surface, dosage of implanted ions, etc. ...
... Difference in work-function between gate and substrate material, oxide thickness, Fermi voltage, charge of impurities trapped at the surface, dosage of implanted ions, etc. ...
Pololu Orangutan SV-xx8 and LV
... you can power servos and other high-power peripherals directly from your regulated voltage. Please note that you should use something more robust than the supplied power-selection shorting blocks if you plan on pulling much more than an amp from a single bank. From left to right, the signal connecti ...
... you can power servos and other high-power peripherals directly from your regulated voltage. Please note that you should use something more robust than the supplied power-selection shorting blocks if you plan on pulling much more than an amp from a single bank. From left to right, the signal connecti ...
User manual
... you to contact us. This will help us to produce manuals that are more user-friendly and to address your wishes and requirements. From the servo amplifier JetMove 208-480 module may result unavoidable residual risks to persons and property. For this reason, any person who has to deal with the transpo ...
... you to contact us. This will help us to produce manuals that are more user-friendly and to address your wishes and requirements. From the servo amplifier JetMove 208-480 module may result unavoidable residual risks to persons and property. For this reason, any person who has to deal with the transpo ...
8.4 Active harmonic conditioner protection
... Should the Active Harmonic Conditioner be overloaded during transient operation of certain loads (e.g. motor start-up, particular sequences, etc.), or permanently, this shall not affect the reliability of its operation. In such cases, the Active Harmonic Conditioner shall operate in a current limiti ...
... Should the Active Harmonic Conditioner be overloaded during transient operation of certain loads (e.g. motor start-up, particular sequences, etc.), or permanently, this shall not affect the reliability of its operation. In such cases, the Active Harmonic Conditioner shall operate in a current limiti ...
On the physical processes ruling an atmospheric pressure air glow
... brightest images that correspond to the passage of the discharge current by its peak value were selected and analyzed (having a similar pixel intensity distribution). It has been shown23 that the diameter of the radiating region in lowcurrent high-pressure discharges in air is about twice smaller th ...
... brightest images that correspond to the passage of the discharge current by its peak value were selected and analyzed (having a similar pixel intensity distribution). It has been shown23 that the diameter of the radiating region in lowcurrent high-pressure discharges in air is about twice smaller th ...
MAX II Development Board
... power supply powers up first, because it is the source for the 3.3-V/2.5-V power supply. The 3.3-V/2.5-V VCCINT supply powers up second. You can increase or decrease the rate at which the VCCINT supply comes up by ...
... power supply powers up first, because it is the source for the 3.3-V/2.5-V power supply. The 3.3-V/2.5-V VCCINT supply powers up second. You can increase or decrease the rate at which the VCCINT supply comes up by ...
Contract drawings and documents
... LED type. Lamps shall be of such construction so that these can be replaced very easily. Typical Indication Circuit diagram for RTCC panel is attached as Fig. 3.2. ...
... LED type. Lamps shall be of such construction so that these can be replaced very easily. Typical Indication Circuit diagram for RTCC panel is attached as Fig. 3.2. ...
14 Power Factor Correction
... be the control of the PF. This will be offset against the increase in space required for more capacitors and the cost for additional contactors. The only variation to this is for fixed duty loads (e.g. particular motor) where a single PFC step used in conjunction with the equipment is justified or m ...
... be the control of the PF. This will be offset against the increase in space required for more capacitors and the cost for additional contactors. The only variation to this is for fixed duty loads (e.g. particular motor) where a single PFC step used in conjunction with the equipment is justified or m ...
Buck converter
A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.